ABSTRACT

When constructing sewerage shield tunnels, a general approach for the sake of cost effectiveness and construction performance is to use steel segments for primary lining and cast-in-place concrete for secondary lining. In this case, the secondary lining has functions of corrosion prevention, waterproofing, and smoothing of the inner surface, which are not sufficiently achieved by the conventional primary lining.