ABSTRACT

From the performance-based concrete quality control described in Chapter 8, average values and standard deviation of both chloride diffusivity and concrete cover are obtained. Upon completion of the concrete construction, therefore, these data are used as input parameters to a new durability analysis which provides the documentation of compliance with the specified durability (Chapter 6).