ABSTRACT

Three bedroom, four person house; Type A

Ground floor Living room

2 no. pendant light fittings 4 no. double socket outlets; switched 2 no. plate switches 1 no. carbon monoxide detector with fuse connection unit (where gas-fire fitted)

Kitchen 1 no. fluorescent fitting 1 no. plate switch 4 no. double socket outlets; switched 1 no. cooker control unit with connection unit 1 no. immersion switch with neon indicator 3 no. switched spurs 3 no. single socket outlets; switched

Dining room 1 no. plate switch 2 no. double socket outlets; switched

1 no. plate switch (hall, landing and outside light, if fitted) 1 no. double socket outlet; switched 1 no. smoke alarm (interconnected) 1 no. bulkhead fitting; external (if fitted)

Store/boiler cupboard 1 no. switched spur for boiler

Rear vestibule 1 no. pendant light fitting 1 no. plate switch (vestibule and outside light) 1 no. bulkhead fitting; external

First floor Landing

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. single socket outlet; switched

Bedroom 1 2 no. double socket outlets, switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 2 2 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 3 1 no. double socket outlet; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 no. pull switch 1 no. tungsten luminaire; Zones 1-3 inclusive 1 no. pull switch for shower

1 no. double pole switched connection unit with flex outlet for immersion heater

Garage 2 no. batten light fitting 1 no. surface-mounted plate switch 1 no. surface-mounted twin socket outlet; switched 1 no. surface-mounted fuse connection unit; switched

Three bedroom, five person house; Type B

Ground floor Living room

2 no. pendant light fittings 4 no. double socket outlets; switched 2 no. plate switches 1 no. carbon monoxide detector unswitched fuse connection unit

(where gas-fire fitted)

Kitchen 1 no. fluorescent fitting 1 no. plate switch 4 no. double socket outlets; switched 1 no. cooker control unit with connection unit 1 no. immersion switch with neon indicator 3 no. switched spurs 3 no. single socket outlets; switched

Dining room 1 no. plate switch 1 no. single socket outlet; switched 2 no. double socket outlets; switched 1 no. pendant light fitting

Hall 1 no. pendant light fitting 1 no. plate switch (hall, landing and outside light) 1 no. double socket outlet; switched 1 no. smoke alarm (interconnected) 1 no. bulkhead fitting; external

Store/boiler cupboard

1 no. batten lamp holder 1 no. plate switch (external to WC)

Rear vestibule 1 no. pendant light fitting 1 no. plate switch (vestibule and outside light) 1 no. bulkhead fitting; external

First floor Landing

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. single socket outlet; switched

Bedroom 1 2 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 2 2 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 3 1 no. single socket outlet; switched 1 no. double socket outlet; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 no. pull switch 1 no. tungsten luminaire; Zones 1-3 inclusive 1 no. pull switch for shower

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

immersion heater

Garage 1 no. batten light fitting 2 no. surface-mounted plate switch 1 no. surface-mounted twin socket outlet; switched 1 no. surface-mounted fuse connection unit; switched

Four bedroom, seven person house; Type C

Ground floor Living room

2 no. pendant light fittings 4 no. double socket outlets; switched 2 no. plate switches 1 no. carbon monoxide detector unswitched fuse connection unit

(where gas-fire fitted)

Kitchen 1 no. fluorescent fitting 1 no. plate switch 4 no. double socket outlets; switched 1 no. cooker control unit with connection unit 1 no. immersion switch with neon indicator 3 no. switched spurs 3 no. single socket outlets; switched

Dining room 1 no. plate switch 1 no. single socket outlet; switched 2 no. double socket outlets; switched 1 no. pendant light fitting

Hall 1 no. pendant light fitting 1 no. plate switch (hall, landing and outside light) 1 no. double socket outlet; switched 1 no. smoke alarm (interconnected) 1 no. bulkhead fitting; external

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

Rear vestibule 1 no. pendant light fitting 1 no. plate switch (vestibule and external light) 1 no. bulkhead fitting; external 1 no. single socket outlet; switched

First floor Landing

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. single socket outlet; switched

Bedroom 1 2 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 2 2 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 no. pull switch 3 no. tungsten luminaire; Zones 1-3 inclusive 1 no. pull switch for shower

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

Cylinder cupboard 1 no. double pole switched connection unit with flex outlet for

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. single socket outlet; switched

Bedroom 3 2 no. double socket outlet; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 4 1 no. single socket outlet; switched 1 no. double socket outlet; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 no. pull switch

1 no. tungsten luminaire; Zones 1-3 inclusive

One bedroom, two person bungalow; Type D

Ground floor Hall

1 no. pendant light fitting 1 no. plate switch 1 no. double socket outlet; switched 1 no. smoke alarm (interconnected)

Living room 3 no. double socket outlets; switched 2 no. pendant light fittings 2 no. plate switches

Kitchen 1 no. batten lamp holder 1 no. plate switch 2 no. double socket outlets; switched

1 no. cooker control unit with connection unit

1 no. immersion switch with neon indicator

2 no. switched spurs

2 no. single socket outlets; switched 1 no. isolating switch for extract fan

Store/boiler cupboard 1 no. switched spur for boiler

Rear vestibule 1 no. pendant light fitting 1 no. plate switch (vestibule and outside light) 1 no. bulkhead fitting; external

Bathroom 1 no. pull switch 1 no. tungsten luminaire; Zones 1-3 inclusive 1 no. pull switch for shower 1 no. isolating switch for extract fan

Bedroom 1 no. pendant light fitting 1 no. plate switch 2 no. double socket outlets; switched

Cylinder cupboard 1 no. double pole switched connection unit with flex outlet for

immersion heater

REWIRING OF THREE BEDROOM, FOUR PERSON HOUSE

EXISTING SERVICES

Isolate, disconnect, cut back and remove existing wiring, accessories, fittings and the like and remove from site Item 37.06

LV/HV CABLES AND WIRING

600/1000 volt grade, PVC insulated, PVC sheathed cable, single core

New meter tails including liaison with local electricity authority/shipper for accessing meter and re-sealing on completion

25mm2

600/1000 volt grade, PVC insulated, PVC sheathed; including PVC capping where necessary

Drawn into voids or chases or clipped to backgrounds; twin and earth cabling

1.5mm2 2.5mm2 6.0mm2

Item 25.07

200 m 2.68 536.00 150 m 3.22 483.00 50 m 8.53 426.50

£

Brought forward 1,507.63

Drawn into voids or chases or clipped to backgrounds; three core and earth cabling

1.5mm2 15 m 5.19 77.85

300/500 volt grade, PVC insulated, PVC sheathed heat resistant circular cables; copper stranded conductors; BS 6141; in tails including termination at both ends

Supply to immersion heater and boiler

3core;2.5mm2 2 m 16.54 33.08

EARTHING AND BONDING COMPONENTS

Copper earth connection including copper insulated cables and final connection and PVC capping where necessary

Main earth between incoming main and consumer unit

16mm2 Item 15.99

Supply and install main equipotential earth bonding between incoming mains and other incoming services including earth bonding clamps

10mm2 Item 116.59

Brought forward 1,751.14

Supply and install cross-bonding to water services (sinks, boilers, etc.) including earth bonding clamps

6mm2 Item 59.23

LV SWITCH GEAR AND DISTRIBUTION

Consumer unit; new split-load consumer unit complete with integral isolator, RCCB, MCBs; all suitable rated

SP and N; 15 module split-load insulated consumer unit fitted with various MCBs, the remainder fitted with blanks; to backgrounds requiring fixings

consumer unit 1 each 216.27 216.27 extra for

6 amp, SP MCB (extra lighting and bell transformer) 2 each 15.37 30.74 16 amp, SP MCB (boiler) 1 each 15.37 15.37 32 amp, SP MCB (extra ring mains) 1 each 15.37 15.37 45 amp, SP MCB (shower) 1 each 15.37 15.37 bell transformer 1 each 37.80 37.80

LUMINAIRES AND LAMPS

Surface-mounted internal luminaires

White plastic ceiling rose, lamp holder complete with white flexible PVC insulated cable not exceeding 225mm in length; to backgrounds requiring fixings

pendant 9 each 14.11 126.99

£

Brought forward 2,268.28

White plastic batten lamp holder complete with skirt; to backgrounds requiring fixings

ceiling lamp holder

Tungsten luminaire; IP44 rated complete with GLS lamp and diffuser; to backgrounds requiring fixings

60 watt chrome dome luminaire; zones 1-3

Fluorescent luminaire complete with lamp and perspex diffuser; to backgrounds requiring fixings

1500mm long; single tube

Disconnect, remove, test and re-install tenant's own luminaire

each 13.40

each 35.33

26.80

35.33

each 41.27 41.27

tenant's own luminaire (wall mounted) 2 each 25.10 50.20

ACCESSORIES FOR ELECTRICAL SERVICES

250 volt grade flush-mounted accessories; fixed to existing flushmounted switch boxes

White plastic switch plates; 6 amp

1 gang; 1 way; single pole 7 each 5.81 40.67 2 gang; 2 way; single pole 1 each 9.83 9.83 3 gang; 2 way; single pole 1 each 17.28 17.28 1 gang; 2 way; single pole 2 each 9.08 18.16

Brought forward 2,507.82

White plastic pull switches including base plate; 6 amp

1 way; single pole 1 each 11.36 11.36

250 volt grade flush-mounted accessories; fixed to existing flush-mounted socket boxes and the installation of flexible PVC insulated earth continuity conductor between box and face plate

White plastic outlet plates

13 amp; single switched socket outlet 13 amp; twin switched socket outlet 20 amp; double pole indicated switch engraved 'Immersion heater' 13 amp; switch fuse connection unit including outgoing final connections 45 amp; cooker control unit

1 each 8.35 8.35 7 each 10.53 73.71

1 each 18.48 18.48

1 each 14.36 14.36 1 each 21.50 21.50

250 volt grade flush-mounted accessories including dry lining back boxes; fit into apertures

Switch socket outlets

13 amp; 1 gang 3 each 15.78 47.34 13 amp; 2 gang 9 each 21.38 192.42

Switch fuse indicator unit including outgoing final connections

13 amp; double pole 3 each 22.67 68.01

£

Brought forward 2,963.35

Low-level cooker connection unit including final connections

connection unit 1 each 20.90 20.90

Double pole indicated switch engraved 'Immersion heater'

20 amp; double pole 1 each 19.81 19.81

Unswitched fuse connection unit including outgoing final connections

13 amp

250 volt grade surface-mounted accessories including moulded plastic back boxes; to backgrounds requiring fixings (garage)

White plastic switch plate

1 each 18.78 18.78

1 gang; 1 way; single pole 1 each 8.75 8.75

White plastic switch socket outlets

13 amp; 2 gang 1 each 15.98 15.98

White plastic fuse connection unit; switched

13 amp; double pole 1 each 19.84 19.84

250 volt grade surface-mounted accessories including back boxes; to backgrounds requiring fixings

Brought forward 3,067.41

Double pole indicated pull switch

45 amp; double pole 1 each 28.22 28.22

Sundry work

Door chimes and bell push including associated wiring and protection; to backgrounds requiring fixings

door bell system 1 each 54.18 54.18

250 volt/9 volt grade surface-mounted smoke detector and fire alarm unit complete with rechargeable battery for back-up purposes; hard wired; to backgrounds requiring fixings

Smoke detector/fire alarm unit complete with associated PVC insulated PVC sheathed cable taken from local lighting circuit

smoke detector/fire alarm unit 2 each 53.63 107.26

250 volt/9 volt grade surface-mounted carbon monoxide detector unit complete with rechargeable battery for back-up purposes; hard wired; to backgrounds requiring fixings

Carbon monoxide detector unit complete with associated PVC insulated PVC sheathed cable taken from local power circuit via fuse connection unit

£

Brought forward 3,342.06

EXTERNAL LIGHTING

FITTINGS AND ACCESSORIES

250 volt grade tungsten luminaire complete with lamp; as manufactured by 'Coughtrie'

Surface-mounted bulkhead luminaire including conduit sleeve through wall, bushing; final connections and the like; to backgrounds requiring fixings

'Coughtrie' bulkhead luminaire 1 each 65.33 65.33

Testing

Final testing as per IEE Wiring Regulations and production of standard NICEIC documentation per dwelling

three bedroom, four person house Item 86.99

Operating and training

Demonstrate to each tenant the RCCB and MCBs in operation and hand to each tenant a leaflet covering this operation Item 8.57

Carried forward 3,502.95

Brought forward 3,502.95

BUILDER'S WORK IN CONNECTION WITH ELECTRICAL SERVICES

Cut out in dry lining walls, and make good plaster for

single socket outlet and/or fuse connection unit twin socket outlet low-level cooker connection unit and/or deep pattern socket box

Cut chase in brick or block wall, make good plaster 50mm wide

cable capping

Floor boards; tongued and grooved

lift softwood flooring; using hand tools relay softwood flooring; fixing with screws

UPGRADING OF ELECTRICAL SERVICES TO THREE BEDROOM, FOUR PERSON HOUSE

15 15

each each

m

m m

6.18 6.18

each 6.18

6.70

10.34 3.41

43.26 49.44

12.36

67.00

155.10 51.15

3,881.26

£

REWIRING OF THREE BEDROOM, FIVE PERSON HOUSE

EXISTING SERVICES

Isolate, disconnect, cut back and remove existing wiring, accessories, fittings and the like and remove from site Item 37.06

LV/HV CABLES AND WIRING

600/1000 volt grade, PVC insulated, PVC sheathed cable, single core

New meter tails including liaison with local electricity authority/shipper for accessing meter and re-sealing on completion

25mm2 Item 25.07

600/1000 volt grade, PVC insulated, PVC sheathed; including PVC capping where necessary

Drawn into voids or chases or clipped to backgrounds; twin and earth cabling

1.5mm2 220 m 2.68 589.60 2.5mm2 175 m 3.22 563.50 6.0mm2 50 m 8.53 426.50

Brought forward 1,641.73

Drawn into voids or chases or clipped to backgrounds; three core and earth cabling

1.5mm2 15 m 5.19 77.85

300/500 volt grade, PVC insulated, PVC sheathed heat resistant circular cables; copper stranded conductors; BS 6141; in tails including termination at both ends

Supply to immersion heater and boiler

3core;2.5mm2 2 m 16.54 33.08

EARTHING AND BONDING COMPONENTS

Copper earth connection including copper insulated cables and final connection and PVC capping where necessary

Main earth between incoming main and consumer unit

16mm2 Item 15.99

Supply and install main equipotential earth bonding between incoming mains and other incoming services including earth bonding clamps

10mm2 Item 116.59

£

Brought forward 1,885.24

Supply and install cross-bonding to water services (sinks, boilers, etc.) including earth bonding clamps

6mm2 Item 59.23

LV SWITCH GEAR AND DISTRIBUTION

Consumer unit; new split-load consumer unit complete with integral isolator, RCCB, MCBs; all suitable rated

SP and N; 15 module split-load insulated consumer unit fitted with various MCBs, the remainder fitted with blanks; to backgrounds requiring fixings

consumer unit extra for

6 amp, SP MCB (extra lighting) 16 amp, SP MCB (boiler) 32 amp, SP MCB (extra ring mains)

45 amp, SP MCB (shower)

LUMINAIRES AND LAMPS

Surface-mounted internal luminaires

1 each 216.27 216.27

1 each 15.37 15.37 1 each 15.37 15.37 2 each 15.37 30.74 1 each 15.37 15.37

White plastic ceiling rose, lamp holder complete with white flexible PVC insulated cable not exceeding 225mm in length; to backgrounds requiring fixings

pendant 9 each 14.11 126.99

Brought forward 2,364.58

White plastic batten lamp holder complete with skirt; to backgrounds requiring fixings

ceiling lamp holder 3 each 13.40 40.20

Recessed mains voltage luminaire; IP44 rated complete with opal lens and lamp; fitted into recess formed by others

50 watt GU10 tungsten downlighter; zones 1-3 3 each 24.79 74.37

Fluorescent luminaire complete with lamp and perspex diffuser; to backgrounds requiring fixings

1500mm long; single tube 1 each 41.27 41.27

Install tenant's own wall-mounted luminaire; to backgrounds requiring fixings

tungsten wall lights 2 each 15.87 31.74

ACCESSORIES FOR ELECTRICAL SERVICES

250 volt grade flush-mounted accessories; fixed to existing flush-mounted switch boxes

White plastic switch plates; 6 amp

1 gang; 1 way; single pole 7 each 5.81 40.67 2 gang; 2 way; single pole 1 each 9.83 9.83 3 gang; 2 way; single pole 1 each 17.28 17.28 1 gang; 2 way; single pole 2 each 9.08 18.16

£

Brought forward 2,638.10

White plastic pull switches including base plate; 6 amp

1 way; single pole 1 each 11.36 11.36

250 volt grade flush-mounted accessories; fixed to existing flush-mounted switch boxes and the installation of flexible PVC insulated earth continuity conductor between box and face plate

White plastic outlet plates

13 amp; single switched socket outlet 13 amp; twin switched socket outlet 20 amp; double pole indicated switch engraved 'Immersion heater' 13 amp; switch fuse connection unit including outgoing final connections 50 amp; cooker control unit

250 volt grade flush-mounted accessories including dry lining back boxes; fit into apertures

Switch socket outlets

13 amp; 1 gang 13 amp; 2 gang

Switch fuse indicator unit including outgoing final connections

13 amp; double pole 3 each 22.67 68.01

Carried forward 3,114.87

2 each 8.35 16.70 8 each 10.53 84.24

1 each 18.48 18.48

1 each 14.36 14.36 1 each 21.50 21.50

4 each 17.77 71.08 8 each 21.38 171.04

Low-level cooker connection unit including final connections

connection unit

Double pole indicated switch engraved 'Immersion heater'

20 amp; double pole

Unswitched fuse connection unit including outgoing final connections

13 amp

250 volt grade surface-mounted accessories including moulded plastic back boxes; to backgrounds requiring fixings (garage)

White plastic switch plate

1 gang; 2 way; single pole

White plastic switch socket outlets

13 amp; 2 gang

White plastic fuse connection unit; switched

13 amp; double pole

250 volt grade surface-mounted accessories including back boxes; to backgrounds requiring fixings

Brought forward 3,114.87

1 each 20.90 20.90

1 each 19.81 19.81

1 each 18.78 18.78

2 each 9.84 19.68

1 each 14.00 14.00

1 each 19.84 19.84

£

Brought forward 3,227.88

Double pole indicated pull switch, 45 amp; double pole 1 each 28.22 28.22

250 volt/9 volt grade surface-mounted smoke detector and fire alarm unit complete with rechargeable battery for back-up purposes; hard wired; to backgrounds requiring fixings

Smoke detector/fire alarm unit complete with associated PVC insulated, PVC sheathed cable taken from local lighting circuit

smoke detector/fire alarm unit 2 each 53.63 107.26

250 volt/9 volt grade surface-mounted carbon monoxide detector unit complete with rechargeable battery for back-up purposes; hard wired; to backgrounds requiring fixings

Carbon monoxide detector unit complete with associated PVC insulated, PVC sheathed cable taken from local power circuit via fuse connection unit, carbon monoxide detector unit 1 each 84.99 84.99

EXTERNAL LIGHTING FITTINGS AND ACCESSORIES

250 volt grade tungsten luminaire complete with lamp; as manufactured by 'Coughtrie'

Surface-mounted bulkhead luminaire including sleeve through wall, bushing, final connections and the like; to backgrounds requiring fixings

'Coughtrie'bulkhead luminaire 2 each 65.33 130.66

Brought forward 3,579.01

Testing

Final testing as per IEE Wiring Regulations and production of standard NICEIC documentation per dwelling

three bedroom, five person house

Operating and training

Demonstrate to each tenant the RCCB and MCBs in operation and hand to each tenant a leaflet covering this operation

BUILDER'S WORK IN CONNECTION WITH ELECTRICAL SERVICES

Cut out in dry lining walls, make good plaster for

single socket outlet and/or fuse connection unit twin socket outlet low-level cooker connection unit and/or deep pattern socket box

Cut chase in brick or block wall, make good plaster 50mm wide

cable chase

Floor boards; butt joints

lift softwood flooring; using hand tools relay softwood flooring; fixing with screws

UPGRADING OF ELECTRICAL SERVICES TO THREE BEDROOM, FIVE PERSON HOUSE

15 15

Item

Item

each each

m m

6.18 6.18

each 6.18

10.34 2.43

117.55

8.57

43.26 43.26

12.36

6.70 80.40

155.10 36.45

£

REWIRING OF FOUR BEDROOM, SEVEN PERSON HOUSE

EXISTING SERVICES

Isolate, disconnect, cut back and remove existing wiring, accessories, fittings and the like and remove from site Item 42.25

LV/HV CABLES AND WIRING

600/1000 volt grade, PVC insulated, PVC sheathed cable, single core

New meter tails including liaison with local electricity authority/shipper for accessing meter and re-sealing on completion

25mm2

600/1000 volt grade, PVC insulated, PVC sheathed; including PVC capping where necessary

Drawn into voids or chases or clipped to backgrounds; twin and earth cabling

1.5mm2 2.5mm2 6.0mm2

Item 25.07

250 m 2.68 670.00 200 m 3.22 644.00 50 m 8.53 426.50

Brought forward 1,807.82

Drawn into voids or chases or clipped to backgrounds; three core and earth cabling

1.5mm2 35 m 5.19 181.65

300/500 volt grade, PVC insulated, PVC sheathed heat resistant circular cables; copper stranded conductors; BS 6141; in tails including termination at both ends

Supply to immersion heater and boiler

3core;2.5mm2 2 m 16.54 33.08

EARTHING AND BONDING COMPONENTS

Copper earth connection including copper insulated cables and final connection and PVC capping where necessary

Main earth between incoming main and consumer unit

16mm2 Item 15.99

Supply and install main equipotential earth bonding between incoming mains and other incoming services including earth bonding clamps

10mm2 Item 116.59

£

Brought forward 2,155.13

Supply and Install cross-bonding to water services (sinks, boilers, etc.) including earth bonding clamps

6mm2 Item 82.93

LV SWITCH GEAR AND DISTRIBUTION

Consumer unit; new split-load consumer unit complete with integral isolator, RCCB, MCBs; all suitable rated

SP and N; 17 module split-load insulated consumer unit fitted with various MCBs, the remainder fitted with blanks; to backgrounds requiring fixings

consumer unit 1 each 230.28 230.28 extra for

6 amp, SP MCB (extra lighting and bell transformer) 3 each 15.37 46.11 16 amp, SP MCB (boiler) 1 each 15.37 15.37 32 amp, SP MCB (extra ring mains) 2 each 15.37 30.74 45 amp, SP MCB (shower) 1 each 15.37 15.37 bell transformer 1 each 37.80 37.80

LUMINAIRES AND LAMPS

Surface-mounted internal luminaires

White plastic ceiling rose, lamp holder complete with white flexible PVC insulated cable not exceeding 225mm in length; to backgrounds requiring fixings

pendant 11 each 14.11 155.21

Brought forward 2,768.94

White plastic batten lamp holder complete with skirt; to backgrounds requiring fixings

ceiling lamp holder 2 each 13.40 26.80

Tungsten luminaire; IP44 rated complete with GLS lamp and diffuser; to backgrounds requiring fixings

60 watt chrome dome luminaire; zones 1-3 2 each 35.33 70.66

Fluorescent luminaire complete with lamp and perspex diffuser; to backgrounds requiring fixings

1500mm long; single tube 1 each 41.27 41.27

ACCESSORIES FOR ELECTRICAL SERVICES

250 volt grade flush-mounted accessories; fixed to existing flushmounted switch boxes

White plastic switch plates; 6 amp

1 gang; 1 way; single pole 9 each 5.81 52.29 2 gang; 2 way; single pole 1 each 9.83 9.83 3 gang; 2 way; single pole 1 each 17.28 17.28 1 gang; 2 way; single pole 2 each 9.08 18.16 1 gang; intermediate; single pole 1 each 13.24 13.24

White plastic pull switches including base plate; 6 amp

1 way; single pole 2 each 11.36 22.72

£

Brought forward 3,041.19

250 volt grade flush-mounted accessories; fixed to existing flush-mounted socket boxes and the installation of flexible PVC insulated earth conductor between box and face plate

White plastic outlet plates

13 amp; single switched socket outlet 2 each 8.70 17. ,40 13 amp; twin switched socket outlet 9 each 10.97 98. ,73 20 amp; double pole indicated switch engraved 'Immersion heater' 1 each 19.45 19, .45 13 amp; switch fuse connection unit including outgoing final connections 1 each 14.96 14, .96 50 amp; cooker control unit 1 each 22.16 22 .16 low-level cooker connection unit 1 each 14.26 14 .26