ABSTRACT

Service trenching gang 1 ganger/chargehand (skill rate 4)

10.66

1 skilled operative (skill rate 4)

10.16

2 unskilled operatives (general)

19.04

1 plant operator (skill rate 3)—75% of time

9.29

Total Gang Rate/Hour £ 49.14 RESOURCESPLANT

Trenching JCB 3CX backhoe50% of time

7.11

125 cfm compressor50% of time

2.22

compressor tools: 2 single head scabbler50% of time

1.61

2 t dumper-50% of time

1.60

trench excavator-25% of time

12.57

Total Gang Rate/Hour £ 25.11 LOCATING BURIED COMMUNICATIONS CABLE

Locating buried road lighting and traffic signs cable

in carriageways, footways, bridge decks and paved areas

0.25 12.29 6.28 – m 18.56

in verges and central reserves

0.20 9.83 5.02 – m 14.85

of embankments

TRENCH FOR COMMUNICATIONS CABLE OR DUCT

Trench for cable 300 to 450 mm wide; depth not exceeding 1.5 m

0.15 7.37 3.77 – m 11.15

450 to 600 mm wide; depth not exceeding 1.5 m

0.20 9.83 5.02 – m 14.85

Extra for excavating rock or reinforced concrete in trench

0.50 24.57 12.56 – m337.14

Extra for excavating brickwork or mass concrete in trench

0.40 19.66 10.04 – m329.70

Extra for backfilling with pea gravel

0.02 0.98 0.51 12.68 m314.17

Extra for 450×100 mm sand cable bedding and covering

0.02 0.98 0.51 1.00 m 2.49

Extra for PVC marker tape

0.01 0.25 0.13 0.15 m 0.52

Extra for 150×300 clay cable tiles

0.05 2.46 1.26 3.76 m 7.48

Extra for 150×900 concrete cable tiles

0.03 1.47 0.76 6.39 m 8.63

rate £ COMMUNICATIONS CABLE AND COMMUNICATIONS DUCT

Communications cables laid in trench not exceeding 1.5 m

type A12 pair 0.9 mm2 armoured multi-pair

– – – – m 3.86

type A2 20 pair 0.9 mm2 armoured multipair

– – – – m 6.94

type A3 30 pair 0.9 mm2 armoured multi-

– – – – m 8.48

trench

type A4 10.0 mm2 armoured split concentric

– – – – m 6.07

Detector feeder cables laid in trench

type A6 50/0.25 m2 single core detector feeder cable

– – – – m 4.63

type A7 50/0.25 m2 single core detector feeder cable

– – – – m 4.63

COMMUNICATIONS CABLE JOINTS AND TERMINATIONS

Cable terminations of type 1 cable – – – – nr 44.93 of type 2 cable – – – – nr 200.62 of type 3 cable – – – – nr 287.75 of type 4 cable – – – – nr 48.15 of type 6 cable – – – – nr 28.66 of type 7 cable – – – – nr 28.66 COMMUNICATIONS EQUIPMENT

Cabinet bases foundation plinth – – – – nr 100.24 Matrix signal post bases foundation plinth – – – – nr 103.79 CCTV camera bases foundation plinth – – – – nr 100.24 Wall mounted brackets at maximum 15.0 m height

– – – – nr 33.43

Fix only the following equipment

communication equipment cabinet, 600 type series

– – – – nr 103.08

terminator type II – – – – nr 109.26 emergency telephone post

– – – – nr 54.77

telephone housing – – – – nr 17.13 matrix signal post – – – – nr 54.77 Motorwarn/fogwarn – – – – nr 109.42 distributor on gantry – – – – nr 139.31

heater unit mounted on gantry; Henleys’ 65 W type 22501

– – – – nr 20.79

Terminal blocks Klippon BK6 – – – – nr 6.49 Klippon BK12 – – – – nr 7.24 Work to pavement for loop detection circuits

cut or form grooves in pavement for detector loops and feeders

– – – – m 3.84

rate £ additional cost for sealing with hot bitumen sealant

– – – – m 0.40

CHAMBERS Brick chamber with galvanised steel cover and frame; depth to uppermost surface of base slab

ne 1.0 m deep – – – – nr 507.00