ABSTRACT
The tests conditions with the hydraulic servoactuator are harmonic vibrations at:
• Very low frequency (quasi-static conditions) • 10 Hz (first mode of isolation) • 30 Hz (second mode of isolation)
The maximum amplitudes of elastomer strain are around 20%. The set-up is in vertical configuration, the actuator is fixed on the hammer.