ABSTRACT

Factories Owner occupation: Includes for rainwater, soil/waste, LTHW heating via HL radiant heaters, BMS, LV installations, lighting, fire alarms, security, earthing m² 115.00 to 140.00 Owner occupation: Includes for rainwater, soil/waste, sprinklers, LTHW heating via HL gas fired heaters, local air conditioning, BMS, HV/LV installations, lighting, fire alarms, security, earthing m² 170.00 to 210.00

Warehouses High bay for owner occupation: Includes for rainwater, soil/waste, LTHW heating via HL gas fired heaters, BMS, HV/LV installations, lighting, fire alarms, security, earthing m² 95.00 to 115.00 High bay for owner occupation: Includes for rainwater, soil/waste, sprinklers, LTHW heating via HL radiant heaters, local air conditioning, BMS, HV/LV installations, lighting, fire alarms, security, earthing m² 190.00 to 230.00

Distribution Centres High bay for letting: Includes for rainwater, soil/waste, LTHW heating via HL gas fired heaters, BMS, HV/LV installations, lighting, fire alarms, security, earthing m² 115.00 to 140.00 High bay for owner occupation: Includes for rainwater, soil/waste, sprinklers, LTHW heating via HL radiant heaters, local air conditioning, BMS, HV/LV installations, lighting, fire alarms, security m² 200.00 to 240.00

Office Buildings 5,000m² to 15,000m²

Offices for Letting Shell & Core and Cat A non-air conditioned: Includes for rainwater, soil/waste, cold water, hot water via local electrical heaters, LTHW heating via radiator heaters, toilet extract, controls, LV installations, lighting, small power (landlords), fire alarms, earthing, security & IT wireways m² 270.00 to 330.00 Shell & Core and Cat A non-air conditioned: Includes for rainwater, soil/waste, cold water, hot water, LTHW heating via perimeter heaters, toilet extract, controls, LV installations, lighting, small power (landlords), fire alarms, earthing, security wireways, IT wireways m² 280.00 to 340.00 Shell & Core and Cat A air conditioned: Includes for rainwater, soil/waste, VRV 3 pipe heat pumps, toilet extract, BMS, LV installations, lighting, small power (landlords), fire alarms, earthing, security & IT wireways m² 390.00 to 480.00 Shell & Core and Cat A air conditioned: Includes for rainwater, soil/waste, cold water, hot water via local electrical heaters, LTHW heating via perimeter heaters, 2 pipe, toilet extract, BMS, LV installations, lighting, small power (landlords), fire alarms, earthing, security & IT wireways m² 430.00 to 530.00

Typical square metre rates for Engineering Services – cont

Office Buildings 5,000m² to 15,000m² – cont

Offices for Owner Occupation Non-air conditioned: Includes for rainwater, soil/waste, cold water, hot water via local electrical heaters, dry risers, LTHW heating via radiator heaters, toilet extract, controls, LV installations, lighting, small power (landlords), fire alarms, earthing, security, IT wireways m² 280.00 to 340.00 Non-air conditioned: Includes for rainwater, soil/waste, cold water, hot water, dry risers, LTHW heating via perimeter heaters, toilet extract, BMS, LV installations, lighting, small power (landlords), fire alarms, earthing, security, IT wireways m² 300.00 to 370.00 Air conditioned: Includes for rainwater, soil/waste, cold water, hot water via electrical heaters, dry risers, LTHW heating via perimeter heating, 4 pipe air conditioning, toilet extract, kitchen extract, sprinkler protection, BMS, LV installations, life safety standby generators, lighting, small power, fire alarms, earthing, security, IT wireways small power, fire alarms L1/P1, earthing, security and IT wireways m² 485.00 to 590.00

Health and Welfare Facilities

District General Hospitals Natural ventilation: Includes for rainwater, soil/waste, cold water, hot water, dry risers, medical gases, LTHW heating via perimeter heating, toilet extract, kitchen extract, BMS, LV installations, standby generation, lighting, small power, fire alarms, earthing/lightning protection, nurse call systems, security, IT wireways m² 430.00 to 530.00 Natural ventilation: Includes for rainwater, soil/waste, cold water, hot water, dry risers, LTHW heating via perimeter heaters, localized VAV air conditioning, kitchen/toilet extract, BMS, LV installations, standby generation, lighting, small power, fire alarms, earthing/lightning protection, nurse call systems, security, IT wireways m² 610.00 to 750.00

Private Hospitals Air conditioned: Includes for rainwater, soil/waste, cold water, hot water, dry risers, medical gases, LTHW heating, 2 pipe air conditioning, toilet extract, kitchen extract, BMS, LV installations, standby generation, lighting, small power, fire alarms, earthing, nurse call systems, security, IT wireways m² 680.00 to 830.00 Air conditioned: Includes for rainwater, soil/waste, cold water, hot water, dry risers, medical gases, LTHW heating, 4 pipe air conditioning, kitchen/toilet extract, BMS, LV installations, standby generation, lighting, small power, fire alarms, earthing, nurse call system, security, IT wireways m² 730.00 to 890.00

Day Care Unit Natural ventilation: Includes for rainwater, soil/waste, cold water, hot water via local electrical heaters, medical gases, LTHW heating, toilet extract, kitchen extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 430.00 to 530.00 Comfort cooled: Includes for rainwater, soil/waste, cold water, hot water, medical gases, LTHW heating, DX air conditioning, kitchen/toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 460.00 to 560.00

Entertainment and Recreation Buildings

Non-Performing Natural ventilation: Includes for rainwater, soil/waste, cold water, central hot water, dry risers, LTHW heating, toilet extract, kitchen extract, controls, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 310.00 to 380.00 Comfort cooled: Includes for rainwater, soil/waste, cold water, hot water via electrical heaters, sprinklers/dry risers, LTHW heating, DX air conditioning, kitchen/toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 530.00 to 650.00

Performing Arts (with Theatre) Natural ventilation: Includes for rainwater, soil/waste, cold water, central hot water, sprinklers/dry risers, LTHW heating, toilet extract, kitchen extract, controls, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 495.00 to 610.00 Comfort cooled: Includes for rainwater, soil/waste, cold water, central hot water, sprinklers/dry risers, LTHW heating, DX air conditioning, kitchen/toilet extract, BMS, LV installations, lighting including enhanced dimming/scene setting, small power, fire alarms, earthing, security, IT wireways including production, audio and video recording, EPOS system m² 670.00 to 810.00

Sports Halls Natural ventilation: Includes for rainwater, soil/waste, cold water, hot water gas fired heaters, LTHW heating, toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security m² 225.00 to 275.00 Comfort cooled: Includes for rainwater, soil/waste, cold water, hot water via LTHW heat exchangers, LTHW heating, air conditioning via AHU's, toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security m² 320.00 to 390.00

Multi-Purpose Leisure Centre Natural ventilation: Includes for rainwater, soil/waste, cold water, hot water gas fired heaters, LTHW heating, toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 315.00 to 385.00 Comfort cooled: Includes for rainwater, soil/waste, cold water, hot water LTHW heat exchangers, LTHW heating, air conditioning via AHU, pool hall supply/extract, kitchen/toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 550.00 to 670.00

Retail Buildings

Open Arcade Natural ventilation: Includes for rainwater, soil/waste, cold water, hot water, sprinklers/dry risers, LTHW heating, toilet extract, smoke extract, BMS, LV installations, life safety standby generators, lighting, small power, fire alarms, public address, earthing/lightning protection, security, IT wireways m² 325.00 to 395.00

Enclosed Shopping Mall Air conditioned: Includes for rainwater, soil/waste, cold water, hot water, sprinklers/dry risers, LTHW heating, air conditioning via AHUs, toilet extract, smoke extract, BMS, LV installations, life safety standby generators, lighting, small power, fire alarms, public address, earthing/lightning protection, CCTV/ security, IT wireways people counting systems m² 470.00 to 570.00

Typical square metre rates for Engineering Services – cont

Retail Buildings – cont

Department Stores Air conditioned: Includes for sanitaryware, soil/waste, cold water, hot water, sprinklers/dry risers, LTHW heating, air conditioning via AHUs, toilet extract, smoke extract, BMS, LV installations, life safety standby generators, lighting, small power, fire alarms, public address, earthing, lightning protection, CCTV/ security, IT installation wireways m² 370.00 to 450.00

Supermarkets Air conditioned: Includes for rainwater, soil/waste, cold water, hot water, sprinklers, LTHW heating, air conditioning via AHUs, toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, lightning protection, security, IT wireways, refrigeration m² 540.00 to 660.00

Educational Buildings

Secondary Schools (Academy) Natural Ventilation: Includes for rainwater, soil/waste, cold water, central hot water, LTHW heating, toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 310.00 to 380.00 Natural vent with comfort cooling to selected areas (BB93 compliant): Includes for rainwater, soil/waste, cold water, central hot water, LTHW heating, DX air conditioning, general supply/extract, toilet extract, BMS, LV installations, lighting, small power, fire alarms, earthing, security, IT wireways m² 370.00 to 450.00

Scientific Buildings

Educational Research Comfort cooled: Includes for rainwater, soil/waste, cold water, central hot water, dry risers, compressed air, medical gasses, LTHW heating, 4 pipe air conditioning, toilet extract, fume, BMS, LV installations, lighting, small power, fire alarms, earthing, lightning protection, security, IT wireways m² 690.00 to 850.00 Air conditioned: Includes for rainwater, soil/waste, laboratory waste, cold water, central hot water, specialist water, dry risers, compressed air, medical gasses, steam, LTHW heating, VAV air conditioning, Comm room cooling, toilet extract, fume extract, BMS, LV installations, UPS, standby generators, lighting, small power, fire alarms, earthing, lightning protection, security, IT wireways m² 1225.00 to 1500.00

Commercial Research Air conditioned; Includes for rainwater, soil/waste, laboratory waste, cold water, central hot water, specialist water, dry risers, compressed air, medical gasses, steam, LTHW heating, VAV air conditioning, Comm room cooling, toilet extract, fume extract, BMS, LV installations, UPS, standby generators, lighting, small power, fire alarms, earthing, lightning protection, security, IT wireways m² 1350.00 to 1650.00

Residential Facilities

Hotels 1 to 3 Star: Includes for rainwater, soil/waste, cold water, hot water, dry risers, LTHW heating via radiators, toilet/bathroom extract, kitchen extract, BMS, LV installations, lighting, small power, fire alarms, earthing, lightning protection, security, IT wireways m² 420.00 to 520.00 4 to 5 Star: Includes for rainwater, soil/waste, cold water, hot water, sprinklers, dry risers, 4 pipe air conditioning, kitchen extract, toilet/bathroom extract, BMS, LV installations, life safety standby generators, lighting, small power, fire alarms, earthing, security, IT wireways m² 750.00 to 910.00