ABSTRACT

By hand 600mm deep – 0.24 5.71 – – m 5.71 800mm deep – 0.43 10.15 – – m 10.15 1.00m deep – 0.67 15.83 – – m 15.83

Backfilling of trenches; including laying of electrical marker tape; compacting lightly as work proceeds To trenches containing armoured cable

by machine 0.16 – – 2.37 0.16 m 2.53 by hand 0.16 0.20 4.75 – 0.16 m 4.91

PC Labour Labour Plant Excluding site overheads and profit £ hours £ £ £ rate £

To trenches containing ducted cable; including 150mm sharp sand over the duct

by machine 2.62 – – 2.97 2.62 m 5.59 by hand 2.62 0.25 5.94 – 2.62 m 8.56

Cable to trenches (trenching operations not included); laying only cable Twin core steel wire armoured cable; 50m drums

1.5mm core 0.69 – – – 0.69 m 0.69 2.5mm core 0.95 – – – 0.95 m 0.95

Twin core steel wire armoured cable; lengths less than 50m runs

1.5mm core 0.72 – – – 0.72 m 0.72 2.5mm core 1.02 – – – 1.02 m 1.02

Three core steel wire armoured cable; 50m drums

1.5mm core 0.84 – – – 0.84 m 0.84 2.5mm core 1.19 – – – 1.19 m 1.19 4.0mm core 1.64 – – – 1.64 m 1.64 6.0mm core 2.21 – – – 2.21 m 2.21 10.0mm core 3.53 – – – 3.53 m 3.53

Three core steel wire armoured cable; lengths less than 50m runs

1.5mm core 0.90 – – – 0.90 m 0.90 2.5mm core 1.27 – – – 1.27 m 1.27

Ducts to trenches; twin wall flexible cable ducts with drawstrings; laid on 150mm clean sharp sand Twin wall duct; laying to trenches

63mm×50m coils 1.00 0.02 0.47 – 1.00 m 1.47 110mm×50m coils 1.50 0.02 0.47 – 1.50 m 1.97

Cable drawing through ducts straight runs up to 50m lengths – 1.00 23.75 – – nr 23.75

Terminations to armoured cables; cutting coiling and taping length of cable to receive connection to light fitting, transformer and the like; fixing to temporary post Armoured cable – 0.33 7.91 – – m 7.91 Plain ducted cable – 0.13 2.97 – – m 2.97

Junction boxes; fixing to cables to receive connections to light fittings or transformers; to IP68

PC Labour Labour Plant Excluding site overheads and profit £ hours £ £ £ rate £

CABLES AND SWITCHING – cont Underground jointing box

2 way 32.80 0.33 9.99 – 32.80 m 42.79 3 way 26.45 0.57 17.14 – 26.45 m 43.59

Above-ground jointing box 2 way 11.15 0.33 9.99 – 11.15 m 21.14 3 way 14.95 0.40 12.00 – 14.95 m 26.95

Electrical connections Connections to existing distribution boards

per switching circuit located within 1m of the distribution board; chasing of cables to walls not included – – – – – nr 46.68

Connections to switches; external power cable circuits; connections to internal wall switches; drilling through walls and making good; chasing of cables to walls not included

price for the first circuit 4.50 1.00 23.75 – 51.18 nr 74.93 additional circuits 4.50 – – – 15.70 nr 15.70

LOW VOLTAGE

Low voltage lights; connecting to transformers (transformers shown separately); fixing as described Hunza Spike adjustable spotlight; 63.5mm diameter × 75mm long; c/w 20/35/50 W lamp

stainless steel 161.98 – – – 206.43 nr 206.43 copper 135.54 – – – 147.19 nr 147.19 black 108.18 – – – 119.83 nr 119.83

Hunza Spike spotlight;; 63.5mm diameter × 75mm long; c/w 20/35/50 W lamp

stainless steel 186.97 – – – 198.62 nr 198.62 copper 146.96 – – – 158.61 nr 158.61 black 77.33 – – – 88.98 nr 88.98

Hunza pole lights; single; fixing to concrete base 150×150×150mm

stainless steel 204.35 0.75 17.81 – 216.43 nr 234.24 copper 150.46 0.75 17.81 – 162.52 nr 180.33 black 104.05 0.75 17.81 – 116.12 nr 133.93

Hunza pole lights; double; fixing to concrete base 150×150×150mm

stainless steel 345.97 0.75 17.81 – 358.05 nr 375.86 copper 203.74 0.75 17.81 – 215.82 nr 233.63 black 345.97 0.75 17.81 – 358.05 nr 375.86

PC Labour Labour Plant Excluding site overheads and profit £ hours £ £ £ rate £

Recessed wall lights; eyelid steplights; fixing to brick or stone walls; inclusive of core drilling

stainless steel 32.80 0.75 17.81 – 192.84 nr 210.65 copper 32.80 0.75 17.81 – 188.01 nr 205.82 black 32.80 0.75 17.81 – 188.01 nr 205.82

Hunza; recessed deck path or lawn lights; inclusive of core drilling excavation and all making good

stainless steel light installed to deck 191.16 0.50 11.88 – 202.81 nr 214.69 stainless steel light installed to path 191.16 0.75 17.81 – 202.81 nr 220.62 stainless steel light installed to lawn 191.16 0.40 9.50 – 202.81 nr 212.31 stainless steel driveway light 191.16 0.50 11.88 – 202.81 nr 214.69

Exterior Lighting Transformers

Outdoor transformers for 12 volt exterior lighting; connecting to junction box (not included); IP67 Single light transformers; 100×68×72mm; 50 vA

fused 22.82 – – – 57.82 nr 57.82 unfused 15.86 – – – 50.86 nr 50.86

Two light transformer; 130×85×85mm; 100 vA

fused 38.90 – – – 73.90 nr 73.90 unfused 35.50 – – – 70.50 nr 70.50

Three light transformer; 130×85×85mm; 150 vA

fused 40.38 – – – 75.38 nr 75.38 unfused – – – – 74.90 nr 74.90

Four light transformer; 130×85×100mm; 200 vA

fused 51.13 – – – 86.13 nr 86.13 unfused – – – – 80.20 nr 80.20

PC Labour Labour Plant Excluding site overheads and profit £ hours £ £ £ rate £

GENERAL

Street area floodlighting – General Preamble: There are an enormous number of luminaires available which are designed for small scale urban and garden projects. The designs are continually changing and the landscape designer is advised to consult the manufacturer's latest catalogue. Most manufacturers supply light fittings suitable for column, bracket, bulkhead, wall or soffit mounting. Highway lamps and columns for trafficked roads are not included in this section as the design of highway lighting is a very specialized subject outside the scope of most landscape contracts. The IP reference number refers to the waterproof properties of the fitting; the higher the number the more waterproof the fitting. Most items can be fitted with time clocks or PIR controls.