ABSTRACT

Buildings over 3,000m² up to 15,000m² m² GIA 16.20 to 19.80 LV Distribution

Buildings up to 3,000m² m² GIA 25.00 to 30.00 Buildings over 3,000m² up to 15,000m² m² GIA 31.50 to 38.50

Lighting Installations (including lighting controls and luminaires) Buildings up to 3,000m² m² GIA 16.20 to 19.80 Buildings over 3,000m² up to 15,000m² m² GIA 16.20 to 19.80 Small Power Buildings up to 3,000m² m² GIA 5.40 to 6.60 Buildings over 3,000m² to up to 15,000m² m² GIA 4.95 to 6.05 Electrical Installations for Mechanical Plant Buildings up to 3,000m² m² GIA 6.30 to 7.70 Buildings over 3,000m² to up to 15,000m² m² GIA 7.20 to 8.80

5.11 Fire and Lightning Protection Fire Protection over 3,000m² to 15,000m² Dry risers m² GIA 3.60 to 4.40 Sprinkler installation m² GIA 16.20 to 19.80 Protective Installations Earthing Buildings up to 3,000m² m² GIA 2.25 to 2.75 Buildings over 3,000m² to 15,000m² m² GIA 2.25 to 2.75 Lightning Protection Buildings up to 3,000m² m² GIA 3.15 to 3.85 Buildings over 3,000m² to 15,000m² m² GIA 2.25 to 2.75

5.12 Communication and Security Installations Fire Alarms (single stage) Buildings up to 3,000m² m² GIA 8.10 to 9.90 Buildings over 3,000m² to 15,000m² m² GIA 10.30 to 12.70 Fire Alarms (phased evacuation) Buildings over 3,000m² to 15,000m² m² GIA 12.20 to 14.80 IT (Wireways only) Buildings up to 3,000m² m² GIA 2.25 to 2.75 Buildings over 3,000m² to 15,000m² m² GIA 2.25 to 2.75 Security Buildings up to 3,000m² m² GIA 6.30 to 7.70 Buildings over 3,000m² to 15,000m² m² GIA 7.20 to 8.80 BMS Controls; including MCC panels and control cabling Full air conditioning m² GIA 16.20 to 19.80

£

Elemental Rates for Alternative Engineering Services Solutions – Offices – cont

Fit Out

5.6 Space Heating and Air Conditioning LPHW Heating Installation; including gas installations Building up to 3,000m² m² NIA 56.00 to 69.00 Building over 3,000m² to 15,000m² m² NIA 45.00 to 55.00 Comfort cooling; 2 pipe fan coil for building up to 3,000m² m² NIA 81.00 to 99.00 2 pipe fan coil for building over 3,000m² to 15,000m² m² NIA 79.00 to 96.00 2 pipe variable refrigerant volume (VRV) for building up to 3,000m² m² NIA 61.00 to 74.00 Full air conditioning; 4 pipe fan coil for building up to 3,000m² m² NIA 120.00 to 150.00 4 pipe fan coil for building over 3,000m² to 15,000m² m² NIA 110.00 to 130.00 4 pipe variable refrigerant volume for building up to 3,000m² m² NIA 100.00 to 120.00 Ventilated (active) chilled beams for building over 3,000m² to 15,000m² m² NIA 120.00 to 150.00 Chilled beam exposed services for building over 3,000m² to 15,000m² m² NIA 185.00 to 230.00 Concealed passive chilled beams for building over 3,000m² to 15,000m² m² NIA 110.00 to 130.00 Chilled ceiling for building over 3,000m² to 15,000m² m² NIA 190.00 to 230.00 Chilled ceiling/perimeter beams for building over 3,000m² to 15,000m² m² NIA 200.00 to 245.00 Displacement for building over 3,000m² to 15,000m² m² NIA 72.00 to 88.00

5.8 Electrical Installations Lighting Installations (including lighting controls and luminaires) Buildings up to 3,000m² m² NIA 45.00 to 55.00 Buildings over 3,000m² to 15,000m² m² NIA 56.00 to 69.00

Electrical Installations for Mechanical Plant Buildings up to 3,000m² m² NIA 6.75 to 8.25 Buildings over 3,000m² to 15,000m² m² NIA 6.75 to 8.25

5.11 Fire and Lightning Protection Fire Protection over 3,000m² to 15,000m² Sprinkler installation m² NIA 25.00 to 30.00 Earthing Buildings up to 3,000m² m² NIA 2.25 to 2.75 Buildings over 3,000m² to 15,000m² m² NIA 2.25 to 2.75

5.12 Communications and Security Installations Fire Alarms (single stage) Buildings up to 3,000m² m² NIA 10.30 to 12.70 Buildings over 3,000m² to 15,000m² m² NIA 10.30 to 12.70 Fire Alarms (phased evacuation) Buildings over 3,000m² to 15,000m² m² NIA 14.00 to 17.00 BMS Controls; including MCC panels and control cabling Full air conditioning m² NIA 16.20 to 19.80

£

Elemental Rates for Alternative Engineering Services Solutions – Hotels

The following examples of building types indicate the range of rates for alternative design solutions for each of the engineering services elements based on Gross Internal Area for the Shell and Core and Net Internal Area for the Fit Out. Fit Out is assumed to be to Cat A Standard.