ABSTRACT

O100101 Walls: 0100101A exceeding 300 mm wide M 2 0.23 10.01 - 6.16 16.17 17.79 0100101B isolated areas n.e. 2.00 m2 M 2 0.34 14.79 - 6.16 20.95 23.05 0100101C isolated areas n.e. 300 mm wide M 2 0.46 20.01 - 6.79 26.80 29.48

O100102Ceilings: M 2 0100102A exceeding 300 mm wide 0.26 11.31 - 5.91 17.22 18.95

0100102B exceeding 300 mm wide; staircase area M 2 0.30 13.05 - 5.91 18.96 20.87

O100103 Isolated beams: 0100103A exceeding 300 mm wide M 2 0.38 16.53 - 6.14 22.67 24.93 0100103B isolated areas n.e. 300 mm wide M 2 0.76 33.06 - 6.36 39.42 43.37

O100104 Isolated columns: 0100104A exceeding 300 mm wide M 2 0.33 14.36 - 6.39 20.75 22.82 0100104B isolated areas n.e. 300 mm wide M 2 0.66 28.71 - 6.39 35.10 38.61

O100105 Pipe encasements: 0100105A exceeding 300 mm wide M 2 0.35 15.23 - 6.39 21.62 23.78 0100105B isolated areas n.e. 300 mm wide M 2 0.70 30.45 - 6.39 36.84 40.53

O1002 9.5 mm wallboard to masonry or concrete walls: fixing by Thistlebond system: joints flush filled, taped and finished for direct decoration

O100201 Walls: 0100201A exceeding 300 mm wide M 2 0.26 11.31 - 6.18 17.49 19.24 0100201B isolated areas n.e. 2.00 m2 M 2 0.39 16.97 - 6.18 23.15 25.46 0100201C isolated areas n.e. 300 mm wide M 2 0.52 22.62 6.18 28.80 31.68

Net

with 10%

€ € €

010 GYPR0C DRY LINING

01002 9.5 mm wallboard to masonry or concrete walls; fixing byThistlebond system; joints flush filled, taped and finished for direct decoration

0100202 0100202A 0100202B

Beams: exceeding 300 mm wide isolated areas n.e. 300 mm wide

M 2 0.43 0.86

18.71 37.41

- 6.41 6.41

25.12 43.82

27.63 48.20

0100203 0100203A 0100203B

Columns: exceeding 300 mm wide isolated areas n.e. 300 mm wide

M 2 0.37 0.74

16.10 32.19

- 6.41 6.41

22.51 38.60

24.75 42.46

0100204 0100204A 0100204B

Pipe encasements: exceeding 300 mm wide isolated areas n.e. 300 mm wide

M 2 0.39 0.78

16.97 33.93

- 6.41 6.41

23.38 40.34

25.71 44.37

01003 12.5 mm wallboard to masonry or concrete walls; fixing by Thistlebond system; joints flush filled, taped and finished for direct decoration

0100301 0100301A 0100301B 0100301C

Walls: exceeding 300 mm wide isolated areas n.e. 2.00 m2

isolated areas n.e. 300 mm wide

0.29 0.44 0.58

12.62 19.14 25.23

- 6.93 6.93 6.93

19.55 26.07 32.16

21.50 28.67 35.37

0100302 Beams: 0100302A exceeding 300 mm wide 0100302B isolated areas n.e. 300 mm wide

M 2 0.48 0.96

20.88 41.76

- 7.15 7.15

28.03 48.91

30.84 53.81

0100303 0100303A 0100303B

Columns: exceeding 300 mm wide isolated areas n.e. 300 mm wide

M 2 0.41 0.82

17.84 35.67

- 7.15 7.15

24.99 42.82

27.49 47.11

0100304 0100304A 0100304B

Pipe encasements: exceeding 300 mm wide isolated areas n.e. 300 mm wide

M 2 0.44 0.87

19.14 37.84

7.15 7.15

26.29 44.99

28.92 49.50

€ € €

010 GYPR0C DRY LINING

01004 12.5 mmFirelineboardtomasonryorconcrete walls; fixing by Thistlebond system; joints flush filled, taped and finished for direct decoration

0100401 Walls: 0100401A exceeding 300 mm wide M 2 0.29 12.62 - 9.31 21.93 24.12 0100401B isolated areas n.e. 2.00 m2 M 2 0.44 19.14 - 9.31 28.45 31.29 0100401C isolated areas n.e. 300 mm wide M 2 0.58 25.23 - 9.31 34.54 37.99

0100402 Beams: 0100402A exceeding 300 mm wide M 2 0.48 20.88 - 9.54 30.42 33.46 0100402B isolated areas n.e. 300 mm wide M 2 0.96 41.76 - 9.54 51.30 56.43

0100403 Columns: 0100403A exceeding 300 mm wide M 2 0.41 17.84 - 9.54 27.38 30.11 0100403B isolated areas n.e. 300 mm wide M 2 0.82 35.67 - 9.54 45.21 49.73

0100404 Pipe encasements: M 2 0100404A exceeding 300 mm wide 0.44 19.14 - 9.54 28.68 31.54

0100404B isolated areas n.e. 300 mm wide M 2 0.87 37.84 - 9.54 47.38 52.12

01005 25mm thermal boardtomasonryorconcrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0100501 Walls: M 2 0100501A exceeding 300 mm wide 0.32 13.92 - 14.39 28.31 31.13

0100501B isolated areas n.e. 2.00 m2 M 2 0.48 20.88 - 14.39 35.27 38.79 0100501C isolated areas n.e. 300 mm wide M 2 0.64 27.84 - 14.39 42.23 46.44

0100502 Beams: 0100502A exceeding 300 mm wide M 2 0.53 23.06 - 14.61 37.67 41.43 0100502B isolated areas n.e. 300 mm wide M 2 1.06 46.11 - 14.61 60.72 66.79

0100503 Columns: 0100503A exceeding 300 mm wide M 2 0.46 20.01 - 14.61 34.62 38.08 0100503B isolated areas n.e. 300 mm wide M 2 0.91 39.59 - 14.61 54.20 59.61

0100504 Pipe encasements: 0100504A exceeding 300 mm wide M 2 0.48 20.88 - 14.61 35.49 39.04 0100504B isolated areas n.e. 300 mm wide M 2 0.96 41.76 14.61 56.37

56.37 62.01

Net

with 10%

€ € € €

010 GYPR0C DRYLINING

01006 32 mm thermal board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0100601 Walls: 0100601A exceeding 300 mm wide 0100601B isolated areasn.e. 2.00m2

0100601C isolated areasn.e. 300mm wide

0100602Beams: 0100602A 0100602B

exceeding 300mm wide isolated areasn.e. 300mm wide

0100603 Columns: 0100603A 0100603B

exceeding 300mm wide isolated areasn.e. 300mm wide

0100604 Pipeencasements: 0100604A exceeding 300mm wide 0100604B isolated areasn.e. 300mm wide

0.34 0.51 0.68

0.56 1.12

0.48 0.97

0.51 1.02

14.79 22.19 29.58

24.36 48.72

20.88 42.20

22.19 44.37

15.82 30.61 15.82 38.01 15.82 45.40

16.04 16.04

16.04 16.04

16.04 16.04

40.40 64.76

36.92 58.24

38.23 60.41

33.67 41.80 49.94

44.45 71.24

40.62 64.06

42.05 66.46

€ € €

010 GYPR0C DRY LINING

01007 40 mm thermal board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0100701 Walls: 0100701A exceeding 300 mm wide M 2 0.36 15.66 - 18.69 34.35 37.79 0100701B isolated areas n.e. 2.00 m2 M 2 0.54 23.49 - 18.69 42.18 46.40 0100701C isolated areas n.e. 300 mm wide M 2 0.72 31.32 - 18.69 50.01 55.01

0100702 Beams: 0100702A exceeding 300 mm wide M 2 0.59 25.67 - 18.92 44.59 49.04 0100702B isolated areas n.e. 300 mm wide M 2 1.18 51.33 - 18.92 70.25 77.27

0100703 Columns: 0100703A exceeding 300 mm wide M 2 0.51 22.19 - 18.92 41.11 45.21 0100703B isolated areas n.e. 300 mm wide M 2 1.03 44.81 - 18.92 63.73 70.10

0100704 Pipe encasements: M 2 0100704A exceeding 300 mm wide 0.54 23.49 - 18.92 42.41 46.65

0100704B isolated areas n.e. 300 mm wide M 2 1.08 46.98 - 18.92 65.90 72.49

01008 50 mm thermal board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0100801 Walls: M 2 0100801A exceeding 300 mm wide 0.38 16.53 - 20.13 36.66 40.32

0100801B isolated areas n.e. 2.00 m2 M 2 0.57 24.80 - 20.13 44.93 49.41 0100801C isolated areas n.e. 300 mm wide M 2 0.76 33.06 - 20.13 53.19 58.51

0100802 Beams: 0100802A exceeding 300 mm wide M 2 0.63 27.41 - 20.35 47.76 52.54 0100802B isolated areas n.e. 300 mm wide M 2 1.26 54.81 - 20.35 75.16 82.68

0100803 Columns: 0100803A exceeding 300 mm wide M 2 0.54 23.49 - 20.35 43.84 48.23 0100803B isolated areas n.e. 300 mm wide M 2 1.08 46.98 - 20.35 67.33 74.07

0100804 Pipe encasements: 0100804A exceeding 300 mm wide M 2 0.57 24.80 - 20.35 45.15 49.66 0100804B isolated areas n.e. 300 mm wide M 2 1.14 49.59 20.35 69.94 76.94

Net

with 10%

0100901 0100901A 0100901B 0100901C

GYPR0C DRY LINING

25 mmvapourcheckthermal board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

Walls: exceeding 300 mm wide isolated areas n.e. 2.00 m2

isolated areas n.e. 300 mm wide

0100902 Beams: 0100902A 0100902B

exceeding 300 mm wide isolated areas n.e. 300 mm wide

0100903 Columns: 0100903A 0100903B

exceeding 300mm wide isolated areasn.e. 300mm wide

0100904 Pipe encasements: 0100904A 0100904B

exceeding 300mm wide isolated areasn.e. 300mm wide

0.32 0.48 0.64

0.53 1.06

0.46 0.92

0.48 0.96

13.92 20.88 27.84

23.06 46.11

20.01 40.02

20.88 41.76

15.53 29.45 15.53 36.41 15.53 43.37

15.76 15.76

15.76 15.76

15.76 15.76

38.82 61.87

35.77 55.78

36.64 57.52

32.40 40.06 47.71

42.69 68.05

39.34 61.35

40.30 63.27

€ € €

010 GYPR0C DRY LINING

01010 32 mm vapour checkthermal boardto masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0101001 Walls: 0101001A exceeding 300 mm wide M 2 0.34 14.79 - 16.97 31.76 34.94 0101001B isolated areas n.e. 2.00 m2 M 2 0.51 22.19 - 16.97 39.16 43.07 0101001C isolated areas n.e. 300 mm wide M 2 0.68 29.58 - 16.97 46.55 51.21

0101002 Beams: 0101002A exceeding 300 mm wide M 2 0.56 24.36 - 17.19 41.55 45.71 0101002B isolated areas n.e. 300 mm wide M 2 1.12 48.72 - 17.19 65.91 72.50

0101003 Columns: 0101003A exceeding 300 mm wide M 2 0.48 20.88 - 17.19 38.07 41.88 0101003B isolated areas n.e. 300 mm wide M 2 0.97 42.20 - 17.19 59.39 65.32

0101004 Pipe encasements: M 2 0101004A exceeding 300 mm wide 0.51 22.19 - 17.19 39.38 43.31

0101004B isolated areas n.e. 300 mm wide M 2 1.02 44.37 - 17.19 61.56 67.72

01011 40 mm vapourcheckthermal boardto masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0101101 Walls: M 2 0101101A exceeding 300 mm wide 0.36 15.66 - 19.84 35.50 39.06

0101101B isolated areas n.e. 2.00 m2 M 2 0.54 23.49 - 19.84 43.33 47.67 0101101C isolated areas n.e. 300 mm wide M 2 0.72 31.32 - 19.84 51.16 56.28

0101102Beams: 0101102A exceeding 300 mm wide M 2 0.59 25.67 - 20.07 45.74 50.30 0101102B isolated areas n.e. 300 mm wide M 2 1.18 51.33 - 20.07 71.40 78.53

0101103 Columns: 0101103A exceeding 300 mm wide M 2 0.51 22.19 - 20.07 42.26 46.47 0101103B isolated areas n.e. 300 mm wide M 2 1.02 44.37 - 20.07 64.44 70.88

0101104 Pipe encasements: 0101104A exceeding 300 mm wide M 2 0.54 23.49 - 20.07 43.56 47.91 0101104B isolated areas n.e. 300 mm wide M 2 1.08 46.98 20.07 67.05 73.75

Net

with 10%

010 GYPR0C DRY LINING

01012 50 mmvapourcheckthermal board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0101201 Walls: 0101201A exceeding 300 mm wide 0101201B isolated areas n.e. 2.00 m2

0101201C isolated areas n.e. 300 mm wide

0101202 Beams: 0101202A exceeding 300 mm wide 0101202B isolated areasn.e. 300mm wide

0101203 Columns: 0101203A exceeding 300 mm wide 0101203B isolated areasn.e. 300mm wide

0101204 Pipe encasements: 0101204A exceeding 300 mm wide 0101204B isolated areas n.e. 300 mm wide

0.38 0.57 0.76

0.63 1.26

0.54 1.08

0.57 1.14

16.53 24.80 33.06

27.41 54.81

23.49 46.98

24.80 49.59

21.28 37.81 21.28 46.08 21.28 54.34

21.50 21.50

21.50 21.50

21.50 21.50

48.91 76.31

44.99 68.48

46.30 71.09

41.59 50.68 59.78

53.80 83.94

49.49 75.33

50.92 78.20

€ € €

010 GYPR0C DRY LINING

01013 25 mm urethane laminate board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

0101301 Walls: 0101301A exceeding 300 mm wide M 2 0.32 13.92 - 24.29 38.21 42.03 0101301B isolated areas n.e. 2.00 m2 M 2 0.48 20.88 - 24.29 45.17 49.69 0101301C isolated areas n.e. 300 mm wide M 2 0.64 27.84 - 24.29 52.13 57.34

0101302 Beams: 0101302A exceeding 300 mm wide M 2 0.53 23.06 - 24.52 47.58 52.33 0101302B isolated areas n.e. 300 mm wide M 2 1.06 46.11 - 24.52 70.63 77.69

0101303 Columns: 0101303A exceeding 300 mm wide M 2 0.46 20.01 - 24.52 44.53 48.98 0101303B isolated areas n.e. 300 mm wide M 2 0.92 40.02 - 24.52 64.54 70.99

0101304 Pipe encasements: M 2 0101304A exceeding 300 mm wide 0.48 20.88 - 24.52 45.40 49.94

0101304B isolated areas n.e. 300 mm wide M 2 0.96 41.76 - 24.52 66.28 72.91

01014 32mm urethanelaminateboardtomasonryor concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for directdecoration

0101401 Walls: M 2 0101401A exceeding 300 mm wide 0.34 14.79 - 26.59 41.38 45.52

0101401B isolated areas n.e. 2.00 m2 M 2 0.51 22.19 - 26.59 48.78 53.65 0101401C isolated areas n.e. 300 mm wide M 2 0.68 29.58 - 26.59 56.17 61.79

0101402 Beams: 0101402A exceeding 300 mm wide M 2 0.56 24.36 - 26.82 51.18 56.30 0101402B isolated areas n.e. 300 mm wide M 2 1.12 48.72 - 26.82 75.54 83.09

0101403 Columns: 0101403A exceeding 300 mm wide M 2 0.48 20.88 - 26.82 47.70 52.47 0101403B isolated areas n.e. 300 mm wide M 2 0.97 42.20 - 26.82 69.02 75.91

0101404 Pipe encasements: 0101404A exceeding 300 mm wide M 2 0.51 22.19 - 26.82 49.01 53.90 0101404B isolated areas n.e. 300 mm wide M 2 1.02 44.37 26.82 71.19 78.31

Net

with 10%

0101501 0101501A 0101501B 0101501C

GYPR0C DRY LINING

40 mm urethane laminate board to masonry or concrete walls; fixing by Thistlebond TL system; joints flush filled, taped and finished for direct decoration

Walls: exceeding 300 mm wide isolated areas n.e. 2.00 m2

isolated areas n.e. 300 mm wide

0101502 Beams: 0101502A 0101502B

exceeding300mmwide isolatedareasn.e. 300mmwide

0101503 Columns: 0101503A 0101503B

exceeding300mmwide isolatedareasn.e. 300mmwide

0101504 Pipeencasements: 0101504A 0101504B

exceeding300mmwide isolatedareasn.e. 300mmwide

0.36 0.54 0.72

0.59 1.18

0.51 1.02

0.54 1.08

15.66 23.49 31.32

25.67 51.33

22.19 44.37

23.49 46.98

29.46 45.12 29.46 52.95 29.46 60.78

29.69 29.69

29.69 29.69

29.69 29.69

55.36 81.02

51.88 74.06

53.18 76.67

49.64 58.25 66.86

60.88 89.11

57.05 81.46

58.49 84.33

€ € €

010 GYPR0C DRY LINING

01016 32 mm tapered edgeTri-line laminate board to masonry or concrete walls; fixing by Gyplyner system; joints flush filled, taped and finished for direct decoration

0101601 Walls: 0101601A exceeding 300 mm wide M 2 0.34 14.79 - 28.05 42.84 47.13 0101601B isolated areas n.e. 2.00 m2 M 2 0.51 22.19 - 28.05 50.24 55.26 0101601C isolated areas n.e. 300 mm wide M 2 0.68 29.58 - 28.05 57.63 63.40

0101602 Beams: 0101602A exceeding 300 mm wide M 2 0.56 24.36 - 28.28 52.64 57.91 0101602B isolated areas n.e. 300 mm wide M 2 1.12 48.72 - 28.28 77.00 84.70

0101603 Columns: 0101603A exceeding 300 mm wide M 2 0.48 20.88 - 28.28 49.16 54.08 0101603B isolated areas n.e. 300 mm wide M 2 0.97 42.20 - 28.28 70.48 77.52

0101604 Pipe encasements: M 2 0101604A exceeding 300 mm wide 0.51 22.19 - 28.28 50.47 55.51

0101604B isolated areas n.e. 300 mm wide M 2 1.02 44.37 - 28.28 72.65 79.92

01017 40mm taperededgeTri-linelaminateboardto masonryorconcretewalls;fixingbyGyplyner system; jointsflushfilled, tapedandfinished for directdecoration

0101701 Walls: M 2 0101701A exceeding 300 mm wide 0.36 15.66 - 32.84 48.50 53.35

0101701B isolated areas n.e. 2.00 m2 M 2 0.54 23.49 - 32.84 56.33 61.96 0101701C isolated areas n.e. 300 mm wide M 2 0.72 31.32 - 32.84 64.16 70.57

0101702 Beams: 0101702A exceeding 300 mm wide M 2 0.59 25.67 - 33.06 58.73 64.60 0101702B isolated areas n.e. 300 mm wide M 2 1.18 51.33 - 33.06 84.39 92.83

0101703 Columns: 0101703A exceeding 300 mm wide M 2 0.51 22.19 - 33.06 55.25 60.77 0101703B isolated areas n.e. 300 mm wide M 2 1.02 44.37 - 33.06 77.43 85.18

0101704 Pipe encasements: 0101704A exceeding 300 mm wide M 2 0.54 23.49 - 33.06 56.55 62.21 0101704B isolated areas n.e. 300 mm wide M 2 1.08 46.98 33.06 80.04

80.04 88.05

Net

with 10%

0101801 0101801A 0101801B 0101801C

GYPR0C DRY LINING

50 mmtapered edgeTri-line laminate board to masonry or concrete walls; fixing by Gyplyner system; joints flush filled, taped and finished for direct decoration

Walls: exceeding 300 mm wide isolated areas n.e. 2.00 m2

isolated areas n.e. 300 mm wide

0101802 Beams: 0101802A 0101802B

exceeding 300mm wide isolated areasn.e. 300mm wide

0101803 Columns: 0101803A 0101803B

exceeding 300mm wide isolated areasn.e. 300mm wide

0101804 Pipe encasements: 0101804A 0101804B

exceeding 300mm wide isolated areasn.e. 300mm wide

0.38 0.57 0.76

0.63 1.26

0.54 1.08

0.57 1.14

16.53 24.80 33.06

27.41 54.81

23.49 46.98

24.80 49.59

38.58 55.11 38.58 63.38 38.58 71.64

38.81 38.81

38.81 38.81

38.81 38.81

66.22 93.62

62.30 85.79

63.61 88.40

60.62 69.71 78.81

72.84 102.98

68.53 94.37

69.96 97.24

€ € €

010 GYPR0C DRY LINING

01019 32 mm tapered edge vapour check Tri-line laminate board to masonry or concrete walls; fixing by Gyplyner system; joints flush filled, taped and finished for direct decoration

0101901 Walls: 0101901A exceeding 300 mm wide M 2 0.34 14.79 - 29.48 44.27 48.70 0101901B isolated areas n.e. 2.00 m2 M 2 0.51 22.19 - 29.48 51.67 56.83 0101901C isolated areas n.e. 300 mm wide M 2 0.68 29.58 - 29.48 59.06 64.97

0101902 Beams: 0101902A exceeding 300 mm wide M 2 0.56 24.36 - 29.71 54.07 59.48 0101902B isolated areas n.e. 300 mm wide M 2 1.12 48.72 - 29.71 78.43 86.27

0101903 Columns: 0101903A exceeding 300 mm wide M 2 0.48 20.88 - 29.71 50.59 55.65 0101903B isolated areas n.e. 300 mm wide M 2 0.97 42.20 - 29.71 71.91 79.09

0101904 Pipe encasements: M 2 0101904A exceeding 300 mm wide 0.51 22.19 - 29.10 51.29 56.41

0101904B isolated areas n.e. 300 mm wide M 2 1.02 44.37 - 29.10 73.47 80.82

01020 40 mm tapered edge vapour check Tri-line laminate board to masonry or concrete walls; fixing by Gyplyner system; joints flush filled, taped and finished for direct decoration

0102001 Walls: M 2 0102001A exceeding 300 mm wide 0.36 15.66 - 34.22 49.88 54.87

0102001B isolated areas n.e. 2.00 m2 M 2 0.54 23.49 - 34.22 57.71 63.48 0102001C isolated areas n.e. 300 mm wide M 2 0.72 31.32 - 34.22 65.54 72.09

0102002 Beams: 0102002A exceeding 300 mm wide M 2 0.59 25.67 - 34.07 59.74 65.71 0102002B isolated areas n.e. 300 mm wide M 2 1.18 51.33 - 34.07 85.40 93.94

0102003 Columns: 0102003A exceeding 300 mm wide M 2 0.51 22.19 - 34.22 56.41 62.04 0102003B isolated areas n.e. 300 mm wide M 2 1.02 44.37 - 34.22 78.59 86.45

0102004 Pipe encasements: 0102004A exceeding 300 mm wide M 2 0.54 23.49 - 34.22 57.71 63.48 0102004B isolated areas n.e. 300 mm wide M 2 1.08 46.98 34.22 81.20

81.20 89.32

€ € € € €

010 GYPR0CDRYLINING

01021 50 mm tapered edge vapour check Tri-line laminate board to masonry or concrete walls; fixing by Gyplyner system; joints flush filled, taped and finished for direct decoration

0102101 Walls: 0102101A exceeding 300 mm wide M 2 0.38 16.53 - 36.86 53.39 58.73 0102101B isolated areas n.e. 2.00 m2 M 2 0.57 24.80 - 36.86 61.66 67.82 0102101C isolated areas n.e. 300 mm wide M 2 0.76 33.06 - 36.86 69.92 76.92

0102102 Beams: 0102102A exceeding 300 mm wide M 2 0.63 27.41 - 37.08 64.49 70.94 0102102B isolated areas n.e. 300 mm wide M 2 1.26 54.81 - 37.08 91.89 101.08

0102103 Columns: 0102103A exceeding 300 mm wide M 2 0.54 23.49 - 37.08 60.57 66.63 0102103B isolated areas n.e. 300 mm wide M 2 1.08 46.98 - 37.08 84.06 92.47

0102104 Pipe encasements: M 2 0102104A exceeding 300 mm wide 0.57 24.80 - 37.08 61.88 68.06

0102104B isolated areas n.e. 300 mm wide M 2 1.14 49.59 - 37.08 86.67 95.34

01022 Gyproc Drywall topcoat

0102201 0ne coat Gyproc Drywall topcoatto surfaces of tapered edge boarding including filling,taping and finishing joints flush; ready for direct decoration:

0102201A walls; exceeding 300 mm wide M 2 0.17 7.40 - 1.63 9.03 9.92 0102201B ceilings; exceeding 300 mm wide M 2 0.21 9.14 - 1.41 10.55 11.60 0102201C skirtings, bands, strings, coverings kerbs,

mouldings, channels and the like; not exceeding 300 mm wide m 0.10 4.35 - 0.45 4.80 5.29

0102202 0ne coat Gyproc Drywall topcoatto surfaces of boarding excluding filling, taping and joint finishing; ready for direct decoration:

M 2 0102202A walls; exceeding 300 mm wide 0.12 5.22 - 0.69 5.91 6.50 0102202B ceilings; exceeding 300 mm wide M 2 0.15 6.53 - 0.69 7.22 7.94 0102202C skirtings, bands, strings, coverings kerbs,

mouldings, channels and the like; not exceeding 300 mm wide m 0.07 3.04 0.23 3.27 3.60

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01111 9.5 mm wallboard to woodwork backgrounds

0111101 Walls: 0111101A exceeding 300 mm wide M 2 0.13 5.66 - 4.04 9.70 10.66 0111101B isolated areas n.e. 2.00 m2 M 2 0.20 8.70 - 4.04 12.74 14.01 0111101C isolated areas n.e. 300 mm wide M 2 0.26 11.31 - 4.11 15.42 16.96

0111102Ceilings: M 2 0111102A exceeding 300 mm wide 0.15 6.53 - 4.04 10.57 11.62

0111102B exceeding 300 mm wide; staircase area M 2 0.17 7.40 - 4.04 11.44 12.57

0111103 Isolated beams: 0111103A exceeding 300 mm wide M 2 0.21 9.14 - 4.04 13.18 14.49 0111103B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 4.11 17.81 19.59 0111103C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 4.11 22.38 24.62

0111104 Isolated columns: 0111104A exceeding 300 mm wide M 2 0.19 8.27 - 4.04 1 2 . 3 1 13.53 0111104B isolated areas n.e. 2.00 m2 M 2 0.29 12.40 - 4.11 16.51 18.16 0111104C isolated areas n.e. 300 mm wide M 2 0.38 16.53 - 4.11 20.64 22.70

0111105 Pipe encasements: 0111105A exceeding 300 mm wide M 2 0.20 8.70 - 4.04 12.74 14.01 0111105B isolated areas n.e. 2.00 m2 M 2 0.30 13.05 - 4.11 17.16 18.88 0111105C isolated areas n.e. 300 mm wide M 2 0.40 17.40 - 4.11 21.51 23.66

01112 9.5 mm Duplex wallboard to woodwork backgrounds

0111201 Walls: 0111201A exceeding 300 mm wide M 2 0.13 5.66 - 5.47 11.13 12.24 0111201B isolated areas n.e. 2.00 m2 M 2 0.20 8.70 - 5.47 14.17 15.59 0111201C isolated areas n.e. 300 mm wide M 2 0.26 11.31 - 5.55 16.86 18.54

0111202 Ceilings: 0111202A exceeding 300 mm wide M 2 0.15 6.53 - 5.47 12.00 13.20 0111202B exceeding 300 mm wide; staircase area . . . . M 2 0.17 7.40 - 5.47 12.87 14.15

0111203 Isolated beams: 0111203A exceeding 300 mm wide M 2 0.21 9.14 - 5.47 14.61 16.07 0111203B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 5.55 19.25 21.17 0111203C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 5.55 23.82 26.20

0111204 Isolated columns: 0111204A exceeding 300 mm wide M 2 0.19 8.27 - 5.47 13.74 15.11 0111204B isolated areas n.e. 2.00 m2 M 2 0.29 12.40 - 5.55 17.95 19.74 0111204C isolated areas n.e. 300 mm wide M 2 0.38 16.53 - 5.55 22.08 24.28

0111205 Pipe encasements: 0111205A exceeding 300 mm wide M 2 0.20 8.70 - 5.47 14.17 15.59 0111205B isolated areas n.e. 2.00 m2 M 2 0.30 13.05 - 5.55 18.60 20.46 0111205C isolated areas n.e. 300 mm wide M 2 0.40 17.40 5.55 22.95

22.95 25.24

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01113 9.5 mm plaster lath to woodwork backgrounds

0111301 Walls: 0111301A exceeding 300 mm wide M 2 0.13 5.66 - 4.21 9.87 10.85 0111301B isolated areas n.e. 2.00 m2 M 2 0.20 8.70 - 4.21 12.91 14.20 0111301C isolated areas n.e. 300 mm wide M 2 0.26 11.31 - 4.28 15.59 17.15

0111302Ceilings: M 2 0111302A exceeding 300 mm wide 0.15 6.53 - 4.21 10.74 11.81

0111302B exceeding 300 mm wide; staircase area . . . . M 2 0.17 7.40 - 4.21 11.61 12.76

0111303 Isolated beams: 0111303A exceeding 300 mm wide M 2 0.21 9.14 - 4.21 13.35 14.68 0111303B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 4.28 17.98 19.78 0111303C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 4.28 22.55 24.81

0111304 Isolated columns: 0111304A exceeding 300 mm wide M 2 0.19 8.27 - 4.21 12.48 13.72 0111304B isolated areas n.e. 2.00 m2 M 2 0.29 12.40 - 4.28 16.68 18.35 0111304C isolated areas n.e. 300 mm wide M 2 0.38 16.53 - 4.28 20.81 22.89

0111305 Pipe encasements: 0111305A exceeding 300 mm wide M 2 0.20 8.70 - 4.21 12.91 14.20 0111305B isolated areas n.e. 2.00 m2 M 2 0.30 13.05 - 4.28 17.33 19.07 0111305C isolated areas n.e. 300 mm wide M 2 0.40 17.40 4.28 21.68

21.68 23.85

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01114 12.5 mm wallboard to woodwork backgrounds

0111401 Walls: 0111401A exceeding 300 mm wide M 2 0.15 6.53 - 4.78 11.31 12.44 0111401B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 4.78 14.35 15.79 0111401C isolated areas n.e. 300 mm wide M 2 0.30 13.05 - 4.86 17.91 19.70

0111402Ceilings: M 2 0111402A exceeding 300 mm wide 0.17 7.40 - 4.78 12.18 13.39

0111402B exceeding 300 mm wide; staircase area . . . . M 2 0.19 8.27 - 4.78 13.05 14.35

0111403 Isolated beams: 0111403A exceeding 300 mm wide M 2 0.25 10.88 - 4.78 15.66 17.22 0111403B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 4.86 21.17 23.28 0111403C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 4.86 26.61 29.27

0111404 Isolated columns: 0111404A exceeding 300 mm wide M 2 0.21 9.14 - 4.78 13.92 15.31 0111404B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 4.86 18.56 20.41 0111404C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 4.86 23.13 25.44

0111405 Pipe encasements: 0111405A exceeding 300 mm wide M 2 0.22 9.57 - 4.78 14.35 15.79 0111405B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 4.86 19.22 21.13 0111405C isolated areas n.e. 300 mm wide M 2 0.44 19.14 4.86 24.00

24.00 26.39

€ € € € €

011 GYPR0CPLASTERB0ARDLININGS

01115 12.5mm Duplexwallboardtowoodwork backgrounds

0111501 Walls: 0111501A exceeding 300 mm wide M 2 0.15 6.53 - 6.28 12.81 14.08 0111501B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 6.28 15.85 17.43 0111501C isolated areas n.e. 300 mm wide M 2 0.30 13.05 - 6.35 19.40 21.35

0111502Ceilings: M 2 0111502A exceeding 300 mm wide 0.17 7.40 - 6.28 13.68 15.03

0111502B exceeding 300 mm wide; staircase area . . . . M 2 0.19 8.27 - 6.28 14.55 15.99

0111503 Isolated beams: 0111503A exceeding 300 mm wide M 2 0.25 10.88 - 6.28 17.16 18.86 0111503B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 6.35 22.66 24.93 0111503C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 6.35 28.10 30.92

0111504 Isolated columns: 0111504A exceeding 300 mm wide M 2 0.21 9.14 - 6.28 15.42 16.95 0111504B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 6.35 20.05 22.06 0111504C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 6.35 24.62 27.09

0111505 Pipe encasements: M 2 0111505A exceeding 300 mm wide 0.22 9.57 - 6.28 15.85 17.43

0111505B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 6.35 20.71 22.78 0111505C isolated areas n.e. 300 mm wide M 2 0.44 19.14 - 6.35 25.49 28.04

01116 12.5 mm plaster lath to woodwork backgrounds

0111601 Walls: 0111601A exceeding 300 mm wide M 2 0.15 6.53 - 5.10 11.63 12.79 0111601B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 5.10 14.67 16.14 0111601C isolated areas n.e. 300 mm wide M 2 0.30 13.05 - 5.17 18.22 20.05

0111602Ceilings: 0111602A exceeding 300 mm wide M 2 0.17 7.40 - 5.10 12.50 13.74 0111602B exceeding 300 mm wide; staircase area . . . . M 2 0.19 8.27 - 5.10 13.37 14.70

0111603 Isolated beams: 0111603A exceeding 300 mm wide M 2 0.25 10.88 - 5.10 15.98 17.57 0111603B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 5.17 21.48 23.63 0111603C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 5.17 26.92 29.62

0111604 Isolated columns: 0111604A exceeding 300 mm wide M 2 0.21 9.14 - 5.10 14.24 15.66 0111604B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 5.17 18.87 20.76 0111604C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 5.17 23.44 25.79

0111605 Pipe encasements: M 2 0111605A exceeding 300 mm wide 0.22 9.57 - 5.10 14.67 16.14

0111605B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 5.17 19.53 21.48 0111605C isolated areas n.e. 300 mm wide M 2 0.44 19.14 5.17 24.31 26.74

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01117 12.5 mm Fireline board to woodwork backgrounds

0111701 Walls: 0111701A exceeding 300 mm wide M 2 0.15 6.53 - 7.08 13.61 14.97 0111701B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 7.08 16.65 18.32 0111701C isolated areas n.e. 300 mm wide M 2 0.30 13.05 - 7.16 20.21 22.23

0111702Ceilings: M 2 0111702A exceeding 300 mm wide 0.17 7.40 - 7.08 14.48 15.92

0111702B exceeding 300 mm wide; staircase area . . . . M 2 0.19 8.27 - 7.08 15.35 16.88

0111703 Isolated beams: 0111703A exceeding 300 mm wide M 2 0.25 10.88 - 7.08 17.96 19.75 0111703B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 7.16 23.47 25.81 0111703C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 7.16 28.91 31.80

0111704 Isolated columns: 0111704A exceeding 300 mm wide M 2 0.21 9.14 - 7.08 16.22 17.84 0111704B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 7.16 20.86 22.94 0111704C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 7.16 25.43 27.97

0111705 Pipe encasements: M 2 0111705A exceeding 300 mm wide 0.22 9.57 - 7.08 16.65 18.32

0111705B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 7.16 21.52 23.66 0111705C isolated areas n.e. 300 mm wide M 2 0.44 19.14 7.16 26.30 28.92

€ € € € €

011 GYPR0CPLASTERB0ARDLININGS

01121 9.5mm taperededgewallboardtowoodwork backgrounds

0112101 Walls: 0112101A exceeding300mmwide M 2 0.13 5.66 - 4.04 9.70 10.66 0112101B isolated areas n.e. 2.00 m2 M 2 0.20 8.70 - 4.04 12.74 14.01 0112101C isolatedareasn.e. 300mmwide M 2 0.26 11.31 - 4.11 15.42 16.96

0112102 Ceilings: M 2 0112102A exceeding300mmwide 0.15 6.53 - 4.04 10.57 11.62

0112102B exceeding300mmwide; staircasearea . . .. M 2 0.17 7.40 - 4.04 11.44 12.57

0112103 Isolated beams: 0112103A exceeding300mmwide M 2 0.21 9.14 - 4.04 13.18 14.49 0112103B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 4.11 17.81 19.59 0112103C isolatedareasn.e. 300mmwide M 2 0.42 18.27 - 4.11 22.38 24.62

0112104 Isolated columns: 0112104A exceeding300mmwide M 2 0.19 8.27 - 4.04 12.31 13.53 0112104B isolated areas n.e. 2.00 m2 M 2 0.29 12.40 - 4.11 16.51 18.16 0112104C isolatedareasn.e. 300mmwide M 2 0.38 16.53 - 4.11 20.64 22.70

0112105 Pipe encasements: M 2 0112105A exceeding300mmwide 0.20 8.70 - 4.04 12.74 14.01

0112105B isolated areas n.e. 2.00 m2 M 2 0.30 13.05 - 4.11 17.16 18.88 0112105C isolatedareasn.e. 300mmwide M 2 0.40 17.40 4.11 21.51 23.66

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01122 9.5mm tapered edgeDuplexwallboard to woodwork backgrounds

0112201 Walls: 0112201A exceeding300mm wide M 2 0.13 5.66 - 5.47 11.13 12.24 0112201B isolated areas n.e. 2.00 m2 M 2 0.20 8.70 - 5.47 14.17 15.59 0112201C isolatedareas n.e. 300mm wide M 2 0.26 11.31 - 5.55 16.86 18.54

0112202 Ceilings: M 2 0112202A exceeding300mm wide 0.15 6.53 - 5.47 12.00 13.20

0112202B exceeding300mm wide; staircasearea . . . . M 2 0.17 7.40 - 5.47 12.87 14.15

0112203 Isolated beams: 0112203A exceeding300mm wide M 2 0.21 9.14 - 5.47 14.61 16.07 0112203B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 5.55 19.25 21.17 0112203C isolatedareas n.e. 300mm wide M 2 0.42 18.27 - 5.55 23.82 26.20

0112204 Isolated columns: 0112204A exceeding300mm wide M 2 0.19 8.27 - 5.47 13.74 15.11 0112204B isolated areas n.e. 2.00 m2 M 2 0.29 12.40 - 5.55 17.95 19.74 0112204C isolatedareas n.e. 300mm wide M 2 0.38 16.53 - 5.55 22.08 24.28

0112205 Pipe encasements: M 2 0112205A exceeding300mm wide 0.20 8.70 - 5.47 14.17 15.59

0112205B isolated areas n.e. 2.00 m2 M 2 0.30 13.05 - 5.55 18.60 20.46 0112205C isolatedareas n.e. 300mm wide M 2 0.40 17.40 - 5.55 22.95 25.24

01123 12.5mmtaperededgewallboardtowoodwork backgrounds

0112301 Walls: 0112301A exceeding300mm wide M 2 0.15 6.53 - 4.78 11.31 12.44 0112301B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 4.78 14.35 15.79 0112301C isolatedareas n.e. 300mm wide M 2 0.30 13.05 - 4.86 17.91 19.70

0112302 Ceilings: 0112302A exceeding300mm wide M 2 0.17 7.40 - 4.78 12.18 13.39 0112302B exceeding300mm wide; staircasearea . . . . M 2 0.19 8.27 - 4.78 13.05 14.35

0112303 Isolated beams: 0112303A exceeding300mm wide M 2 0.25 10.88 - 4.78 15.66 17.22 0112303B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 4.86 21.17 23.28 0112303C isolatedareas n.e. 300mm wide M 2 0.50 21.75 - 4.86 26.61 29.27

0112304 Isolated columns: 0112304A exceeding300mm wide M 2 0.21 9.14 - 4.78 13.92 15.31 0112304B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 4.86 18.56 20.41 0112304C isolatedareas n.e. 300mm wide M 2 0.42 18.27 - 4.86 23.13 25.44

0112305 Pipe encasements: M 2 0112305A exceeding300mm wide 0.22 9.57 - 4.78 14.35 15.79

0112305B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 4.86 19.22 21.13 0112305C isolatedareas n.e. 300mm wide M 2 0.44 19.14 4.86 24.00 26.39

€ € € € €

011 GYPR0CPLASTERB0ARDLININGS

01124 12.5mm taperededgeDuplexwallboardto woodwork backgrounds

0112401 Walls: 0112401A exceeding300mmwide M 2 0.15 6.53 - 6.28 12.81 14.08 0112401B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 6.28 15.85 17.43 0112401C isolatedareasn.e. 300mmwide M 2 0.30 13.05 - 6.35 19.40 21.35

0112402 Ceilings: M 2 0112402A exceeding300mmwide 0.17 7.40 - 6.28 13.68 15.03

0112402B exceeding300mmwide; staircasearea . . .. M 2 0.19 8.27 - 6.28 14.55 15.99

0112403 Isolated beams: 0112403A exceeding300mmwide M 2 0.25 10.88 - 6.28 17.16 18.86 0112403B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 6.35 22.66 24.93 0112403C isolatedareasn.e. 300mmwide M 2 0.50 21.75 - 6.35 28.10 30.92

0112404 Isolated columns: 0112404A exceeding300mmwide M 2 0.21 9.14 - 6.28 15.42 16.95 0112404B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 6.35 20.05 22.06 0112404C isolatedareasn.e. 300mmwide M 2 0.42 18.27 - 6.35 24.62 27.09

0112405 Pipe encasements: M 2 0112405A exceeding300mmwide 0.22 9.57 - 6.28 15.85 17.43

0112405B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 6.35 20.71 22.78 0112405C isolatedareasn.e. 300mmwide M 2 0.44 19.14 6.35 25.49 28.04

€ € € € €

011 GYPR0C PLASTERB0ARDLININGS

01125 12.5 mm tapered edge Fireline wallboard to woodwork backgrounds

0112501 Walls: 0112501A exceeding300mmwide M 2 0.15 6.53 - 7.17 13.70 15.06 0112501B isolated areas n.e. 2.00 m2 M 2 0.22 9.57 - 7.17 16.74 18.41 0112501C isolatedareasn.e.300mm wide M 2 0.30 13.05 - 7.24 20.29 22.33

0112502 Ceilings: M 2 0112502A exceeding300mmwide 0.17 7.40 - 7.17 14.57 16.01

0112502B exceeding 300 mm wide; staircase area . . . . M 2 0.19 8.27 - 7.17 15.44 16.97

0112503 Isolated beams: 0112503A exceeding 300 mm wide M 2 0.25 10.88 - 7.17 18.05 19.84 0112503B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 7.24 23.55 25.91 0112503C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 7.24 28.99 31.90

0112504 Isolated columns: 0112504A exceeding 300 mm wide M 2 0.21 9.14 - 7.17 16.31 17.93 0112504B isolated areas n.e. 2.00 m2 M 2 0.31 13.70 - 7.24 20.94 23.04 0112504C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 7.24 25.51 28.07

0112505 Pipe encasements: M 2 0112505A exceeding 300 mm wide 0.22 9.57 - 7.17 16.74 18.41

0112505B isolated areas n.e. 2.00 m2 M 2 0.33 14.36 - 7.24 21.60 23.76 0112505C isolated areas n.e. 300 mm wide M 2 0.44 19.14 7.24 26.38 29.02

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01126 15.0mmtaperededgewallboardtowoodwork backgrounds

0112601 Walls: 0112601A exceeding 300 mm wide M 2 0.18 7.83 - 6.71 14.54 15.99 0112601B isolated areas n.e. 2.00 m2 M 2 0.27 11.75 - 6.71 18.46 20.30 0112601C isolated areas n.e. 300 mm wide M 2 0.36 15.66 - 6.78 22.44 24.69

0112602 Ceilings: M 2 0112602A exceeding 300 mm wide 0.21 9.14 - 6.71 15.85 17.43

0112602B exceeding 300 mm wide; staircase area . . . . M 2 0.24 10.44 - 6.71 17.15 18.86

0112603 Isolated beams: 0112603A exceeding 300 mm wide M 2 0.30 13.05 - 6.71 19.76 21.74 0112603B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 6.78 26.36 28.99 0112603C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 6.78 32.88 36.17

0112604 Isolated columns: 0112604A exceeding 300 mm wide M 2 0.25 10.88 - 6.71 17.59 19.34 0112604B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 6.78 23.09 25.40 0112604C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 6.78 28.53 31.39

0112605 Pipe encasements: M 2 0112605A exceeding 300 mm wide 0.27 11.75 - 6.71 18.46 20.30

0112605B isolated areas n.e. 2.00 m2 M 2 0.41 17.62 - 6.78 24.40 26.84 0112605C isolated areas n.e. 300 mm wide M 2 0.54 23.49 - 6.78 30.27 33.30

01127 15.0 mm tapered edge Duplex wallboard to woodwork backgrounds

0112701 Walls: 0112701A exceeding 300 mm wide M 2 0.18 7.83 - 8.15 15.98 17.57 0112701B isolated areas n.e. 2.00 m2 M 2 0.27 11.75 - 8.15 19.90 21.88 0112701C isolated areas n.e. 300 mm wide M 2 0.36 15.66 - 8.22 23.88 26.27

0112702 Ceilings: 0112702A exceeding 300 mm wide M 2 0.21 9.14 - 8.15 17.29 19.01 0112702B exceeding 300 mm wide; staircase area . . . . M 2 0.24 10.44 - 8.15 18.59 20.44

0112703 Isolated beams: 0112703A exceeding 300 mm wide M 2 0.30 13.05 - 8.15 21.20 23.32 0112703B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 8.22 27.80 30.57 0112703C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 8.22 34.32 37.75

0112704 Isolated columns: 0112704A exceeding 300 mm wide M 2 0.25 10.88 - 8.15 19.03 20.92 0112704B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 8.22 24.53 26.98 0112704C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 8.22 29.97 32.97

0112705 Pipe encasements: M 2 0112705A exceeding 300 mm wide 0.27 11.75 - 8.15 19.90 21.88

0112705B isolated areas n.e. 2.00 m2 M 2 0.41 17.62 - 8.22 25.84 28.42 0112705C isolated areas n.e. 300 mm wide M 2 0.54 23.49 8.22 31.71 34.88

€ € € € €

011 GYPR0C PLASTERB0ARD LININGS

01128 15.0 mm tapered edge Fireline wallboard to woodwork backgrounds

0112801 Walls: 0112801A exceeding 300 mm wide M 2 0.18 7.83 - 8.20 16.03 17.63 0112801B isolated areas n.e. 2.00 m2 M 2 0.27 11.75 - 8.20 19.95 21.94 0112801C isolated areas n.e. 300 mm wide M 2 0.36 15.66 - 8.28 23.94 26.33

0112802 Ceilings: M 2 0112802A exceeding 300 mm wide 0.21 9.14 - 8.20 17.34 19.07

0112802B exceeding 300 mm wide; staircase area . . . . M 2 0.24 10.44 - 8.20 18.64 20.50

0112803 Isolated beams: 0112803A exceeding 300 mm wide M 2 0.30 13.05 - 8.20 21.25 23.38 0112803B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 8.28 27.86 30.63 0112803C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 8.28 34.38 37.81

0112804 Isolated columns: 0112804A exceeding 300 mm wide M 2 0.25 10.88 - 8.20 19.08 20.98 0112804B isolated areas n.e. 2.00 m2 M 2 0.38 16.31 - 8.28 24.59 27.04 0112804C isolated areas n.e. 300 mm wide M 2 0.50 21.75 - 8.28 30.03 33.03

0112805 Pipe encasements: M 2 0112805A exceeding 300 mm wide 0.27 11.75 - 8.20 19.95 21.94

0112805B isolated areas n.e. 2.00 m2 M 2 0.41 17.62 - 8.28 25.90 28.48 0112805C isolated areas n.e. 300 mm wide M 2 0.54 23.49 8.28 31.77 34.94

€ € €

011 GYPR0C PLASTERB0ARD LININGS

01129 19.0 mm tapered edge plank to woodwork backgrounds

0112901 Walls: 0112901A exceeding 300 mm wide M 2 0.21 9.14 - 8.37 17.51 19.26 0112901B isolated areas n.e. 2.00 m2 M 2 0.32 13.92 - 8.37 22.29 24.52 0112901C isolated areas n.e. 300 mm wide M 2 0.42 18.27 - 8.45 26.72 29.39

0112902 Ceilings: M 2 0112902A exceeding 300 mm wide 0.24 10.44 - 8.37 18.81 20.69

0112902B exceeding 300 mm wide; staircase area . . . . M 2 0.28 12.18 - 8.37 20.55 22.61

0112903 Isolated beams: 0112903A exceeding 300 mm wide M 2 0.35 15.23 - 8.37 23.60 25.96 0112903B isolated areas n.e. 2.00 m2 M 2 0.53 22.84 - 8.45 31.29 34.41 0112903C isolated areas n.e. 300 mm wide M 2 0.70 30.45 - 8.45 38.90 42.79

0112904 Isolated columns: 0112904A exceeding 300 mm wide M 2 0.30 13.05 - 8.37 21.42 23.57 0112904B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 8.45 28.03 30.82 0112904C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 8.45 34.55 38.00

0112905 Pipe encasements: M 2 0112905A exceeding 300 mm wide 0.32 13.92 - 8.37 22.29 24.52

0112905B isolated areas n.e. 2.00 m2 M 2 0.48 20.88 - 8.45 29.33 32.26 0112905C isolated areas n.e. 300 mm wide M 2 0.64 27.84 8.45 36.29 39.91

€ € €

0 1 2 S A N D CEMENT, C0NCRETE AND GRAN0LITHIC SCREEDS AND FL00RING

01201 Cement and sand (1:3); trowelled finish

0120101 To floors: 0120101A 25 mm thick M 2 0.25 10.88 - 4.24 15.12 16.63 0120101B 32 mm thick M 2 0.27 11.75 - 5.31 17.06 18.76 0120101C 38mmthick M 2 0.29 12.62 - 6.37 18.99 20.88 0 1 2 0 1 0 1 D 5 0 mm thick M 2 0.32 13.92 - 8.34 22.26 24.48 0120101E 65 mm thick M 2 0.36 15.66 - 10.91 26.57 29.24

01202 Cement and sand (1:3); screeded finish

0120201 Tofloors: 0120201A 25 mm thick M 2 0.19 8.27 - 4.24 12.51 13.76 0120201B 32mm thick M 2 0.20 8.70 - 5.31 14.01 15.41 0120201C 38mm thick M 2 0.22 9.57 - 6.37 15.94 17.53 0 1 2 0 2 0 1 D 5 0 m m thick M 2 0.24 10.44 - 8.34 18.78 20.65 0120201E 65mm thick M 2 0.27 11.75 - 10.91 22.66 24.93

01203 Cementandsand(1:3); floatedfinish

0120301 Tofloors: 0120301A 25 mm thick M 2 0.23 10.01 - 4.24 14.25 15.68 0120301B 32mm thick M 2 0.24 10.44 - 5.31 15.75 17.32 0120301C 38mm thick M 2 0.26 11.31 - 6.37 17.68 19.44 0 1 2 0 3 0 1 D 5 0 m m thick M 2 0.29 12.62 - 8.34 20.96 23.05 0120301E 65mm thick M 2 0.32 13.92 10.91 24.83

24.83 27.32

€ € € € €

0 1 2 S A N D CEMENT, C0NCRETE AND GRAN0LITHIC SCREEDS AND FL00RING

01204 Granolithic paving (two parts cementto five parts dustless granite chippings); trowelled finish

0120401 Tofloors: 0120401A 25mmthick M 2 0.30 13.05 - 8.04 21.09 23.21 0120401B 32 mm thick M 2 0.32 13.92 - 10.05 23.97 26.37 0120401C 38 mm thick M 2 0.34 14.79 - 12.06 26.85 29.54 0 1 2 0 4 0 1 D 5 0 mm thick M 2 0.37 16.10 - 15.80 31.90 35.08

0120402 Tostaircasetreadsandlandings: M 2 0120402A 25mm thick 0.88 38.28 - 8.04 46.32 50.96

0120402B 32mm thick M 2 0.94 40.89 - 10.05 50.94 56.04 0120402C 38mm thick M 2 1.00 43.50 - 12.06 55.56 61.12 0 1 2 0 4 0 2 D 5 0 m m thick M 2 1.09 47.42 - 15.80 63.22 69.54

0120403 Torisersandedgesoflandings;notexceeding 150mm wide:

0120403A 25mm thick m 0.15 6.48 - 1.15 7.63 8.39 0120403B 32mm thick m 0.16 7.05 - 1.72 8.77 9.65 0120403C 38mm thick m 0.17 7.40 - 2.01 9.41 10.34 0 1 2 0 4 0 3 D 5 0 m m thick m 0.17 7.35 - 2.59 9.94 10.93

0120404 To risers and edges of landings; 150-300 mm wide:

0120404A 25mm thick m 0.26 11.48 - 2.30 13.78 15.16 0120404B 32mm thick m 0.29 12.53 - 3.16 15.69 17.25 0120404C 38mm thick m 0.30 13.05 - 3.73 16.78 18.47 0 1 2 0 4 0 4 D 5 0 m m thick m 0.32 13.92 - 4.88 18.80 20.68

0120405 Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsand thelike; not exceeding 300mm wide:

0120405A 25mm thick m 0.22 9.57 - 2.30 11.87 13.06 0120405B 32mm thick m 0.24 10.44 - 3.16 13.60 14.95 0120405C 38mm thick m 0.25 10.88 - 3.73 14.61 16.07 0 1 2 0 4 0 5 D 5 0 m m thick m 0.27 11.75 4.88 16.63

16.63 18.29

Net

with 10%

0130101 0130101A 0130101B

0140101A 0140101B 0140101C

0140111A 0140111B

0140121A 0140121B

LEVELLING C0MP0UNDS T0 FL00RS

Evostikfloor levelling compound, laid in accordance with the manufacturer's instructions

To floors and landings; nominal thickness: 2 mm m2

PLASTERED, RENDERED & R0UGHCAST C0ATINGS

Gyproc Drywall topcoat

To walls; one coat Gyproc Drywall top coat to surfaces of tapered edge boarding including filling, taping and finishing joints flush; ready for direct decoration:

exceeding 300 mm wide isolated areas n.e. 2.00 m2

isolated areas n.e. 300 mm wide

Toceilings; onecoat Gyproc Drywall top coatto surfaces of tapered edge boarding including filling, taping and finishing joints flush; ready for direct decoration:

exceeding 300 mm wide exceeding 300 mm wide; staircase area

To isolated beams; one coat Gyproc Drywall top coat to surfaces of tapered edge boarding including filling, taping and finishing joints flush; ready for direct decoration:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

0.13 0.15

0.17 0.26 0.34

0.21 0.24

0.21 0.28

5.66 6.53

7.40 11.09 14.79

9.14 10.44

9.14 12.35

6.56 12.22 16.41 22.94

1.63 1.63 12.72 1.63 16.42

1.41 1.41

1.41 1.41

10.55 11.85

10.55 13.76

13.44 25.23

9.92 13.99 18.06

11.60 13.03

11.60 15.14

€ € € € €

014 PLASTERED, RENDERED & R0UGHCAST C0ATINGS

01401 Gyproc Drywall topcoat

0140141 To isolated columns; one coat Gyproc Drywall top coat to surfaces of tapered edge boarding including filling, taping and finishing joints flush; ready for direct decoration:

M 2 0140141A exceeding 300 mm wide 0.17 7.40 - 1.63 9.03 9.92 0140141B isolated areas n.e. 300 mm wide M 2 0.23 10.01 - 1.63 11.64 12.80

0140161 Toskirtings, bands, strings, coveringstokerbs and the like; one coat Gyproc Drywall top coat tosurfaces of tapered edge boarding including filling, taping and finishing joints flush; ready for direct decoration:

0140161A notexceeding 150 mm wide m 0.08 3.26 - 0.23 3.49 3.84 0140161B 150-300 mm wide m 0.10 4.35 - 0.45 4.80 5.29

01411 Carlite lightweight plastering with 2 mm Carlite finish plaster

0141101 To walls; 10 mm thick; two coat work; to concrete backgrounds with bonding backings:

M 2 0141101A exceeding 300 mm wide 0.30 13.05 - 2.63 15.68 17.25 0141101B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 2.63 22.21 24.42 0141101C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 2.63 28.73 31.60

0 1 4 1 1 0 2 T o walls; 10 mm thick; two coat work; to plasterboard backgrounds with bonding backings; including scrimming joints:

M 2 0141102A exceeding 300 mm wide 0.30 13.05 - 2.97 16.02 17.62 0141102B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 2.97 22.55 24.79 0141102C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 2.97 29.07 31.97

0141103 To walls; 13 mm thick; two coat work; to masonry backgrounds with browning backings:

M 2 0141103A exceeding 300 mm wide 0.30 13.05 - 3.01 16.06 17.67 0141103B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 3.01 22.59 24.84 0141103C isolated areas n.e. 300 mm wide M 2 0.60 26.10 3.01 29.11

29.11 32.02

€ € € € €

014 PLASTERED, RENDERED & R0UGHCAST C0ATINGS

01411 Carlite lightweight plastering with 2 mm Carlite finish plaster

0141104 To walls; 13 mm thick; two coat work; to masonry backgrounds with special browning backings:

M 2 0141104A exceeding 300 mm wide 0.30 13.05 - 3.13 16.18 17.80 0141104B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 3.13 22.71 24.97 0141104C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 3.13 29.23 32.15

0141105 To walls; 13 mm thick; two coat work; to masonry backgrounds with browning HSB backings:

M 2 0141105A exceeding 300 mm wide 0.30 13.05 - 3.18 16.23 17.85 0141105B isolated areas n.e. 2.00 m2 M 2 0.45 19.58 - 3.18 22.76 25.02 0141105C isolated areas n.e. 300 mm wide M 2 0.60 26.10 - 3.18 29.28 32.20

0141106 To walls; 13 mm thick; three coat work; metal lathing backgrounds with metal lathing backings:

M 2 0141106A exceeding 300 mm wide 0.40 17.40 - 5.29 22.69 24.96 0141106B isolated areas n.e. 2.00 m2 M 2 0.60 26.10 - 5.29 31.39 34.53 0141106C isolated areas n.e. 300 mm wide M 2 0.80 34.80 - 5.29 40.09 44.10

0141111 To ceilings; 10 mm thick; two coat work; to concrete backgrounds with bonding backings:

M 2 0141111A exceeding 300 mm wide 0.34 14.79 - 2.63 17.42 19.16 0141111B exceeding 300 mm wide; staircase area M 2 0.39 17.01 - 2.63 19.64 21.60

0141112Toceilings; 10mm thick;twocoatwork; to plasterboard backgrounds with bonding backings; including scrimming joints:

M 2 0141112A exceeding 300 mm wide 0.34 14.79 - 2.97 17.76 19.53 0141112B exceeding 300 mm wide; staircase area . . . . M 2 0.39 17.01 - 2.97 19.98 21.97

0141116 To ceilings; 13 mm thick; three coat work; to metal lathing backgrounds with metal lathing backings:

0141116A exceeding 300 mm wide M 2 0.45 19.58 - 5.29 24.87 27.35 0141116B exceeding 300 mm wide; staircase area . . . . M 2 0.52 22.53 5.29 27.82 30.61

with 10%

€ € € €

0141121A 0141121B

0141122A 0141122B

0141126A 0141126B

0141141A 0141141B

PLASTERED, RENDERED & R0UGHCAST C0ATINGS

Carlitelightweightplastering with 2mm Carlitefinish plaster

Toisolated beams; 10mm thick; twocoat work; toconcretebackgroundswith bonding backings:

Toisolated beams; 10mm thick; twocoat work; to plasterboard backgrounds with bondingbackings;includingscrimmingjoints:

Toisolated beams; 13mm thick; threecoat work;tometallathingbackgroundswithmetal lathing backings:

exceeding 300mm wide isolated areasn.e. 300mm wide

Toisolated columns; 10mm thick; twocoat work; toconcretebackgroundswith bonding backings:

exceeding 300mm wide isolated areasn.e. 300mm wide

0141142Toisolated columns; 10mm thick; twocoat work; to plasterboard backgrounds with bondingbackings;includingscrimmingjoints:

0141142A 0141142B

0141143A 0141143B

exceeding 300mm wide isolated areasn.e. 300mm wide

Toisolated columns; 13mm thick; twocoat work; tomasonrybackgroundswith browning backings:

exceeding 300mm wide isolated areasn.e. 300mm wide

0.34 0.46

0.34 0.46

0.45 0.61

0.30 0.41

0.30 0.41

0.30 0.41

14.79 19.97

14.79 19.97

19.58 26.45

13.05 17.62

13.05 17.62

13.05 17.62

2.63 2.63

5.29 5.29

2.63 2.63

17.42 22.60

2.97 17.76 2.97 22.94

24.87 31.74

15.68 20.25

2.97 16.02 2.97 20.59

3.01 16.06 3.01 20.63

19.16 24.85

19.53 25.22

27.35 34.91

17.25 22.27

17.62 22.64

17.67 22.69

014 PLASTERED, RENDERED&R0UGHCAST C0ATINGS

01411 Carlitelightweightplasteringwith 2mm Carlite finish plaster

0141144 Toisolatedcolumns; 13mm thick; twocoat work; tomasonrybackgroundswith special browning backings:

0141145 Toisolatedcolumns; 13mm thick; twocoat work; tomasonrybackgroundswith browning HSB backings:

0141146 Toisolatedcolumns; 13mm thick; threecoat work; metallathingbackgroundswith metal lathing backings:

0141161 Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsandthelike; 10mm thick; twocoatwork; toconcrete backgroundswithbondingbackings:

0141161A notexceeding150mm wide m 0141161B 150-300mmwide m

0141162Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsandthelike; 10mm thick; twocoatwork; toplasterboard backgroundswithbondingbackings;including scrimming joints:

0141162A notexceeding150mm wide m 0141162B 150-300mmwide m

0141163 Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsandthelike; 13mm thick; twocoatwork; tomasonry backgroundswithbrowningbackings:

0141163A notexceeding150mm wide m 0141163B 150-300mmwide m

€ €

0.30 13.05 - 3.13 16.18 17.80 0.41 17.62 - 3.13 20.75 22.82

0.30 13.05 - 3.18 16.23 17.85 0.41 17.62 - 3.18 20.80 22.87

0.40 17.40 - 5.29 22.69 24.96 0.54 23.49 - 5.29 28.78 31.66

0.13 5.79 - 0.31 6.10 6.70 0.18 7.83 - 0.86 8.69 9.55

0.13 5.79 - 0.36 6.15 6.75 0.18 7.83 - 0.96 8.79 9.66

0.13 5.79 - 0.63 6.42 7.06 0.18 7.83 - 1.19 9.02 9.92

0141164A 0141164B

0141165A 0141165B

0141166A 0141166B

PLASTERED, RENDERED & R0UGHCAST C0ATINGS

Carlite lightweight plastering with 2 mm Carlite finish plaster

To skirtings, bands, strings, coverings to kerbs, mouldings, channels and the like; 13 mm thick; two coat work; to masonry backgrounds with special browning backings:

not exceeding 150 mm wide m 150-300 mm wide

Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsandthelike; 13mmthick;twocoatwork;tomasonry backgrounds with browning HSB backings:

not exceeding 150 mm wide m 150-300 mm wide m

Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsandthelike; 13mmthick; threecoatwork;tometallathing backgrounds with metal lathing backings:

not exceeding 150 mm wide m 150-300 mm wide

Thistle2mmfinish onThistlerenovating plaster

Towalls;13mm thick; twocoatwork:

0.13 0.18

0.18 0.24

0.13 5.79 0.18 7.83

5.79 7.83

7.74 10.44

0.66 6.45 1.23 9.06

0.67 1.25

0.90 1.75

6.46 9.08

8.64 12.19

7.09 9.97

7.10 9.99

9.51 13.40

0142101A exceeding 300 mm wide M 2 0.30 13.05 - 4.28 17.33 19.07 0142101B isolated areas n.e. 2.00 m2 M 2 0.35 15.01 - 4.28 19.29 21.22 0142101C isolated areas n.e. 300 mm wide M 2 0.41 17.62 - 4.28 21.90 24.09

0142111 To isolated columns; 13 mm thick; two coat work:

0142111A exceeding 300 mm wide M 2 0.30 13.05 - 4.28 17.33 19.07 0142111B isolated areas n.e. 300 mm wide M 2 0.41 17.62 - 4.28 21.90 24.09

Net

with 10%

PLASTERED, RENDERED & ROUGHCAST COATINGS

Thistle 2 mm finish on Thistle renovating plaster

To skirtings, bands, strings, coverings to kerbs, mouldings, channels and the like; 13 mm thick; two coat work:

0142126A notexceeding 150mmwide m 150-300 mm wide m 0142126B

Thistlefinishing plaster

Towalls; 2mm thick; onecoatwork; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

0143101A exceeding 300 mm wide 0143101B isolated areas n.e. 2.00 m2

0143101C isolated areas n.e. 300 mm wide

0143102 To walls; 5 mm thick; two coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

0.13 0.18

5.79 7.83

0.72 1.43

6.51 9.26

M 2 0.14 6.09 - 1.20 7.29 M 2 0.16 7.00 - 1.20 8.20 M 2 0.19 8.44 - 1.20 9.64

0143102A exceeding 300 mm wide M 2 0.20 8.70 - 2.05 10.75 0143102B isolated areas n.e. 2.00 m2 M 2 0.23 10.01 - 2.05 12.06 0143102C isolated areas n.e. 300 mm wide M 2 0.27 11.75 - 2.05 13.80

0143103 Towalls; 2mm thick;onecoatwork;tosanded backgrounds:

M 2 0143103A exceeding 300 mm wide 0.08 3.48 - 0.57 4.05 0143103B isolated areas n.e. 2.00 m2 M 2 0.09 4.00 - 0.57 4.57 0143103C isolated areas n.e. 300 mm wide M 2 0.11 4.70 - 0.57 5.27

0143113 To ceilings; 2 mm thick; one coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

0143113A exceeding 300 mm wide M 2 0.16 6.96 - 1.20 8.16 0143113B exceeding 300 mm wide; staircase area . . . . M 2 0.18 8.00 - 1.20 9.20

7.15 10.18

8.02 9.02

10.60

11.83 13.27 15.18

4.45 5.02 5.79

8.98 10.12

with 10%

€ € € €

0143114A 0143114B

0143115A 0143115B

0143123A 0143123B

0143124A 0143124B

0143125A 0143125B

0143141A 0143141B

PLASTERED, RENDERED&R0UGHCAST C0ATINGS

Thistle finishing plaster

Toceilings;5mm thick; twocoatwork; to plasterboardbackgroundsincluding scrimming joints and filling nail holes; board finish:

exceeding 300 mm wide exceeding 300 mm wide; staircase area

To ceilings; 2 mm thick; one coat work; to sanded backgrounds:

exceeding 300 mm wide exceeding 300 mm wide; staircase area

To isolated beams; 2 mm thick; one coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

To isolated beams; 5 mm thick; two coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

To isolated beams; 2 mm thick; one coat work; to sanded backgrounds:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

To isolated columns; 2 mm thick; one coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

0.23 0.27

0.10 0.12

0.16 0.22

0.23 0.31

0.10 0.14

0.14 0.19

10.01 11.53

4.35 5.00

6.96 9.40

10.01 13.53

4.35 5.87

6.09 8.22

12.06 13.58

4.92 5.57

8.16 10.60

2.05 2.05

0.57 0.57

1.20 1.20

2.05 2.05

0.57 0.57

1.20 7.29 1.20 9.42

12.06 15.58

4.92 6.44

13.27 14.94

5.41 6.12

8.98 11.66

13.27 17.14

5.41 7.08

8.02 10.36

Net

with 10%

014 PLASTERED, RENDERED & ROUGHCAST COATINGS

01431 Thistle finishing plaster

0143142 TO isolated columns; 5 mm thick; two coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board

0143142A 0143142B

0143143A 0143143B

0143161A 0143161B

finish: exceeding 300 mm wide isolated areas n.e. 300 mm wide

Toisolated columns; 2mm thick; onecoat work; to sanded backgrounds:

To skirtings, bands, strings, coverings to kerbs, mouldings, channelsandthelike;2mm thick; one coatwork; toplasterboard backgrounds including scrimming joints and filling nail holes; board finish:

notexceeding 150mmwide m 150-300 mm wide

0143162 To skirtings, bands, strings, coverings to kerbs, mouldings, channelsandthelike;5mm thick; two coat work; to plasterboard backgrounds including scrimming joints and filling nail holes; board finish:

notexceeding 150mmwide m 0143162A 0143162B

0143163A 0143163B

150-300 mm wide

Toskirtings, bands, strings, coveringsto kerbs, mouldings, channelsandthelike;2mm thick; onecoatwork; tosandedbackgrounds:

notexceeding 150mmwide m 150-300 mm wide

0.20 0.27

0.08 0.11

0.06 0.08

0.18 0.12

0.04 0.05

8.70 11.75

3.48 4.70

2.57 3.48

7.66 5.22

1.61 2.18

2.05 2.05

0.57 0.57

0.05 0.39

0.34 0.67

0.28

10.75 13.80

4.05 5.27

2.62 3.87

8.00 5.89

11.83 15.18

4.45 5.79

2.88 4.26

8.79 6.48

1.77 2.70

m

€ € € € €

014 PLASTERED, RENDERED & R0UGHCAST C0ATINGS

01441 Thistle Universal one coat plaster

0144101 To walls; 10 mm thick; to concrete backgrounds:

M 2 0144101A exceeding 300 mm wide 0.20 8.70 - 3.14 11.84 13.03 0144101B isolated areas n.e. 2.00 m2 M 2 0.23 10.01 - 3.14 13.15 14.47 0144101C isolated areas n.e. 300 mm wide M 2 0.27 11.75 - 3.14 14.89 16.38

0144102 To walls; 5 mm thick; to plasterboard backgrounds including scrimming joints and filling nail holes:

M 2 0144102A exceeding 300 mm wide 0.16 6.96 - 1.75 8.71 9.58 0144102B isolated areas n.e. 2.00 m2 M 2 0.18 8.00 - 1.75 9.75 10.72 0144102C isolated areas n.e. 300 mm wide M 2 0.22 9.40 - 1.75 11.15 12.26

0144103 To walls; 13 mm thick; to masonry backgrounds:

M 2 0144103A exceeding 300 mm wide 0.20 8.70 - 4.19 12.89 14.18 0144103B isolated areas n.e. 2.00 m2 M 2 0.23 10.01 - 4.19 14.20 15.62 0144103C isolated areas n.e. 300 mm wide M 2 0.27 11.75 - 4.19 15.94 17.53

0144111 To ceilings; 10 mm thick; to concrete backgrounds:

M 2 0144111A exceeding 300 mm wide 0.23 10.01 - 3.14 13.15 14.47 0144111B exceeding 300 mm wide; staircase area . . . . M 2 0.27 11.53 - 3.14 14.67 16.14

0 1 4 4 1 1 2 T o ceilings; 5 mm thick; to plasterboard backgrounds including scrimming joints and filling nail holes:

M 2 0144112A exceeding 300 mm wide 0.18 7.83 - 1.75 9.58 10.53 0144112B isolated areas n.e. 2.00 m2 M 2 0.21 9.01 - 1.75 10.76 11.83 0144112C isolated areas n.e. 300 mm wide M 2 0.24 10.57 - 1.75 12.32 13.55

0144121 To isolated beams; 10 mm thick; to concrete backgrounds:

M 2 0144121A exceeding 300 mm wide 0.23 10.01 - 3.14 13.15 14.47 0144121B isolated areas n.e. 300 mm wide M 2 0.31 13.53 3.14 16.67

16.67 18.34

0144122A 0144122B

0144141A 0144141B

PLASTERED, RENDERED & R0UGHCAST C0ATINGS

ThistleUniversal onecoatplaster

Toisolatedbeams;5mmthick;toplasterboard backgroundsincludingscrimming jointsand filling nail holes:

exceeding300mm wide isolatedareas n.e. 300mm wide

To isolated columns; 10 mm thick; to concrete backgrounds:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

0144142 To isolated columns; 5 mm thick; to plasterboard backgrounds including scrimming joints and filling nail holes:

0144142A 0144142B

0144143A 0144143B

exceeding 300 mm wide isolated areas n.e. 300 mm wide

To isolated columns; 13 mmthick; to masonry backgrounds:

exceeding 300 mm wide isolated areas n.e. 300 mm wide

To skirtings, bands, strings, coverings to kerbs, mouldings, channels and the like; 10 mm thick; to concrete backgrounds:

0144161A notexceeding 150mmwide m 0144161B 150-300 mm wide

0144162 To skirtings, bands, strings, coverings to kerbs, mouldings, channelsandthelike;5mm thick; to plasterboard backgrounds including scrimming joints and filling nail holes:

0144162A notexceeding 150mmwide m

0.20 0.27

0.16 0.22

0.20 0.27

0.09 0.12

€ €

0.18 7.83 0.24 10.57

8.70 11.75

6.96 9.40

8.70 11.75

3.87 5.22

0144162B 150-300 mm wide 0.07 3.22 0.10 4.35

€ €

1.75 9.58 1.75 12.32

3.14 3.14

1.75 1.75

4.19 4.19

0.70 1.05

11.84 14.89

8.71 11.15

12.89 15.94

4.57 6.27

0.35 3.57 0.70 5.05

10.53 13.55

13.03 16.38

9.58 12.26

14.18 17.53

5.03 6.89

3.92 5.56

m

m

with 10%

0144163A 0144163B

0145101 0145101A 0145101B 0145101C

0145111A 0145111B

0145121A 0145121B

0145141A 0145141B

0145161A 0145161B

PLASTERED, RENDERED & R0UGHCAST C0ATINGS

Thistle Universal one coat plaster

To skirtings, bands, strings, coverings to kerbs, mouldings, channels and the like; 13 mm thick; to masonry backgrounds:

not exceeding 150 mm wide m 150-300 mm wide

Sirapite Bfinish plaster

To walls; 3 mm thick; to sanded backgrounds: exceeding 300 mm wide isolated areas n.e. 2.00 m2

isolated areas n.e. 300 mm wide

To ceilings; 3 mm thick; to sanded backgrounds:

exceeding 300 mm wide exceeding 300 mm wide; staircase area .