ABSTRACT

Locating buried road lighting and traffic signs cable in carriageways, footways, bridge decks and paved areas 0.25 16.18 8.86 – m 25.04 in verges and central reserves 0.20 12.94 7.09 – m 20.03 in side slopes of cuttings or side slopes of embankments 0.15 9.71 5.32 – m 15.03

TRENCH FOR COMMUNICATIONS CABLE OR DUCT

Trench for cable 300 to 450mm wide; depth not exceeding 1.5m 0.15 9.71 5.32 – m 15.03 450 to 600mm wide; depth not exceeding 1.5m 0.20 12.94 7.09 – m 20.03 Extra for excavating rock or reinforced concrete in trench 0.50 32.35 17.74 – m3 50.09 Extra for excavating brickwork or mass concrete in trench 0.40 25.88 14.18 – m3 40.06 Extra for backfilling with pea gravel 0.02 1.29 0.72 19.81 m3 21.82 Extra for 450×100mm sand cable bedding and covering 0.02 1.29 0.72 1.45 m 3.46 Extra for PVC marker tape 0.01 0.32 0.19 2.17 m 2.68 Extra for 150×300 clay cable tiles 0.05 3.24 1.77 4.94 m 9.95 Extra for 150×900 concrete cable tiles 0.03 1.94 1.07 8.39 m 11.40

hours £ £ £ rate £

COMMUNICATIONS CABLING AND DUCT

Communication cables laid in trench type A1 2 pair 0.9mm² armoured multi-pair – – – – m 4.62 type A2 20 pair 0.9mm² armoured multi-pair – – – – m 8.29 type A3 30 pair 0.9mm² armoured multi-pair – – – – m 10.19

Power cables laid in trench type A4 10.0mm² armoured split concentric – – – – m 7.07

Detector feeder cables laid in trench type A6 50/0.25m² single core detector feeder cable – – – – m 8.93 type A7 50/0.25m² single core detector feeder cable – – – – m 8.93

COMMUNICATIONS CABLE JOINTS AND TERMINATIONS

Cable terminations of type 1 cable – – – – nr 65.94 of type 2 cable – – – – nr 294.63 of type 3 cable – – – – nr 422.63 of type 4 cable – – – – nr 70.67 of type 6 cable – – – – nr 42.10 of type 7 cable – – – – nr 42.10

COMMUNICATIONS EQUIPMENT

Cabinet bases foundation plinth – – – – nr 133.46

Matrix signal post bases foundation plinth – – – – nr 138.18

CCTV camera bases foundation plinth – – – – nr 133.46

Wall mounted brackets at maximum 15.0m height – – – – nr 44.52

Fix only the following equipment communication equipment cabinet, 600 type series – – – – nr 140.32 terminator type II – – – – nr 148.73 emergency telephone post – – – – nr 74.52 telephone housing – – – – nr 23.27 matrix signal post – – – – nr 74.52 Motorwarn / fogwarn – – – – nr 148.93 distributor on gantry – – – – nr 189.63 isolator switch for gantry – – – – nr 412.97 heater unit mounted on gantry; Henleys' 65 W type 22501 – – – – nr 28.29

hours £ £ £ rate £

COMMUNICATIONS EQUIPMENT – cont

Terminal blocks Klippon BK6 – – – – nr 7.67 Klippon BK12 – – – – nr 8.61

Work to pavement for loop detection circuits cut or form grooves in pavement for detector loops and feeders – – – – m 5.00 additional cost for sealing with hot bitumen sealant – – – – m 0.51

CHAMBERS

Brick chamber with galvanized steel cover and frame; depth to uppermost surface of base slab

ne 1.0m deep – – – – nr 892.42