ABSTRACT

Locating buried road lighting and traffic signs cable in carriageways, footways, bridge decks and paved areas 0.25 15.78 8.88 - m 24.66 in verges and central reserves 0.20 12.63 7.10 - m 19.73 in side slopes of cuttings or side slopes of embankments 0.15 9.47 5.33 - m 14.80

TRENCH FOR COMMUNICATIONS CABLE OR DUCT

Trench for cable 300 to 450 mm wide; depth not exceeding 1.5 m 0.15 9.47 5.33 - m 14.80 450 to 600 mm wide; depth not exceeding 1.5 m 0.20 12.63 7.10 - m 19.73 Extra for excavating rock or reinforced concrete in trench 0.50 31.56 17.76 - m3 49.32 Extra for excavating brickwork or mass concrete in trench 0.40 25.25 14.20 - m3 39.45 Extra for backfilling with pea gravel 0.02 1.26 0.72 20.27 m3 22.25 Extra for 450 x 100 mm sand cable bedding and covering 0.02 1.26 0.72 1.49 m 3.47 Extra for PVC marker tape 0.01 0.32 0.19 0.19 m 0.69 Extra for 150 x 300 clay cable tiles 0.05 3.16 1.77 4.83 m 9.76 Extra for 150 x 900 concrete cable tiles 0.03 1.89 1.07 8.21 m 11.17

COMMUNICATIONS CABLE AND COMMUNICATIONS DUCT

Communication cables laid in trench type A1 2 pair 0.9 mm2 armoured multi-pair - - - - m 4.51 type A2 20 pair 0.9 mm2 armoured multi-pair - - - - m 8.10 type A3 30 pair 0.9 mm2 armoured multi-pair - - - - m 9.94

Item Gang Labour Plant Material Unit Total hours £ £ £ rate £

Power cables laid in trench type A4 10.0 mm2 armoured split concentric - - - - m 7.07

Detector feeder cables laid in trench type A6 50/0.25m2 single core detector feeder cable - - - - m 5.43 type A7 50/0.25m2 single core detector feeder cable - - - - m 5.43

COMMUNICATIONS CABLE JOINTS AND TERMINATIONS

Cable terminations of type 1 cable - - - - nr 64.37 of type 2 cable - - - - nr 287.62 of type 3 cable - - - - nr 412.56 of type 4 cable - - - - nr 68.98 of type 6 cable - - - - nr 41.10 of type 7 cable - - - - nr 41.10

COMMUNICATIONS EQUIPMENT

Cabinet bases foundation plinth - - - - nr 130.28

Matrix signal post bases foundation plinth - - - - nr 134.89

CCTV camera bases foundation plinth - - - - nr 130.28

Wall mounted brackets at maximum 15.0 m height - - - - nr 43.46

Fix only the following equipment communication equipment cabinet, 600 type series - - - - nr 140.32 terminator type II - - - - nr 148.73 emergency telephone post - - - - nr 74.52 telephone housing - - - - nr 23.27 matrix signal post - - - - nr 74.52 Motorwarn / fogwarn - - - - nr 148.93 distributor on gantry - - - - nr 189.63 isolator switch for gantry - - - - nr 412.97 heater unit mounted on gantry; Henleys' 65 W type 22501 - - - - nr 28.29

Terminal blocks Klippon BK6 - - - - nr 7.48 Klippon BK12 - - - - nr 8.40

Work to pavement for loop detection circuits cut or form grooves in pavement for detector loops and feeders - - - - m 5.02 additional cost for sealing with hot bitumen sealant - - - - m 0.51

CHAMBERS

Brick chamber with galvanised steel cover and frame; depth to uppermost surface of base slab ne 1.0 m deep - - - - nr 839.92