ABSTRACT

The bond between reinforcing bars and concrete is an essential requirement of reinforced concrete. The maximum bond stress will vary depending on the thickness of the concrete cover. Analyses with an elastic-brittle and plastic material assumptions lead to a lower and an upper bound, respectively, to experimental data. It is shown that modelling concrete as a strain-softening material yields best agreement between analytical prediction of bond failure due to splitting and test results.