Flat Roof with Box Gutter CI/SfB52.5 TYPICAL SOLUTION
Pages 3

Theoretically 100 mm is slightly undersized and could be accepted on the grounds of economy, but some engineers may select 125 mm, which would provide a large amount of reserve capacity which may be necessary for windborne rain.