ABSTRACT

A previously presented model for the addition of the convective and nucleate boiling components is explored further. The model is based on the concept of suppression of convective heat transfer due to the presence of nucleate boiling. It is demonstrated that this alternative model of flow boiling can provide reasonably good predictions of measured data. The comparisons of published experimental data for R12 with the predictions are presented here. Some areas of further work are described.