ABSTRACT

The corrosion resistance required for use in concrete is primarily a resistance against pitting corrosion in chloride containing media. The danger of pitting corrosion decreases with a decline of chloride content and rising pH-value. Therefore, stainless steels are basically more resistant in concrete construction with a pH-value of about 8 to 13 than in atmospheric weather conditions.