ABSTRACT

ABSTRACT: An under construction 28-storey reinforced concrete building was instrumented to observe its axial shortening behavior. A number of columns and core walls at 1st floor levels have been instrumented for axial shortening measurements.A brief outlines on the field experiment, the laboratory concrete testing program, and the method used to estimate long-term axial shortening is presented.