ABSTRACT

DRAINAGE TO STRUCTURES ABOVE GROUND Note Outputs are based on heights up to 3 m above ground and exclude time spent on erecting access equipment, but include marking, cutting, drilling to wood, brick or concrete and all fixings. Testing of finished work is not included. Output multipliers for labour and plant for heights over 3 m : 3 - 6 m x 1.25 6 - 9 m x 1.50 9 - 12 m x 1.75 12 - 15 m x 2.00 Cast iron gutters and fittings; BS 460 2002 100 x 75 mm gutters; support brackets 0.25 6.66 0.46 36.22 m 43.34 stop end 0.03 0.72 0.05 26.03 nr 26.80 running outlet 0.04 0.93 0.06 26.70 nr 27.69 angle 0.04 0.93 0.06 40.44 nr 41.43 125 x 75 mm gutters; support brackets 0.30 7.99 0.55 49.44 m 57.99 stop end 0.03 0.85 0.06 31.94 nr 32.85 running outlet 0.04 1.07 0.07 34.53 nr 35.67 angle 0.04 1.07 0.07 53.09 nr 54.23 Cast iron rainwater pipes and fittings; BS 460 2002 65 mm diameter; support brackets 0.26 6.93 0.47 21.44 m 28.84 bend 0.28 7.46 0.51 12.56 nr 20.53 offset, 75 mm projection 0.30 7.99 0.55 18.86 nr 27.40 offset, 225 mm projection 0.30 7.99 0.55 21.96 nr 30.50 offset, 455 mm projection 0.30 7.99 0.55 60.08 nr 68.63 shoe 0.18 4.80 0.33 20.13 nr 25.25 75 mm diameter; support brackets 0.28 7.46 0.51 22.04 m 30.02 bend 0.28 7.46 0.51 14.96 nr 22.93 offset, 75 mm projection 0.30 7.99 0.55 18.86 nr 27.40 offset, 225 mm projection 0.30 7.99 0.55 21.96 nr 30.50 offset, 455 mm projection 0.30 7.99 0.55 60.08 nr 68.63 shoe 0.18 4.80 0.33 20.13 nr 25.25 PVC-U gutters and fittings; Marley 116 x 75 mm gutters; support brackets 0.18 4.80 0.33 9.77 m 14.89 stop end 0.05 1.33 0.09 4.05 nr 5.47 running outlet 0.05 1.33 0.09 14.48 nr 15.90 angle 0.14 3.73 0.26 17.67 nr 21.66 150 mm half round gutters; support brackets 0.18 4.80 0.33 12.48 m 17.61 stop end 0.05 1.33 0.09 5.51 nr 6.93 running outlet 0.05 1.33 0.09 15.27 nr 16.70 angle 0.14 3.73 0.26 13.95 nr 17.94 PVC-U external rainwater pipes and fittings; Marley 68 mm diameter; support brackets 0.15 4.00 0.27 7.44 m 11.71 bend 0.16 4.26 0.29 8.19 nr 12.75 offset bend 0.18 4.80 0.33 4.53 nr 9.66 shoe 0.10 2.66 0.18 7.08 nr 9.93 110 mm diameter; support brackets 0.15 4.00 0.27 16.95 m 21.22 bend 0.16 4.26 0.29 20.09 nr 24.64 offset bend 0.18 4.80 0.33 19.43 nr 24.55 shoe 0.10 2.66 0.18 16.24 nr 19.09

Item

Gang hours

Labour £

Plant £

Material £ Unit

Total rate £

ROCK FILLED GABIONS Gabions PVC coated galvanised wire mesh box gabions, wire laced; graded broken stone filling 1.0 x 1.0 m module sizes 0.65 46.94 10.29 54.23 m3 111.46 1.0 x 0.5 m module sizes 0.80 57.77 12.66 67.07 m3 137.51 Heavily galvanised woven wire mesh box gabions, wire laced; graded broken stone filling 1.0 x 1.0 m module sizes 0.65 46.94 10.29 49.62 m3 106.85 1.0 x 0.5 m module sizes 0.80 57.77 12.66 59.77 m3 130.21 Reno mattresses PVC coated woven wire mesh mattresses, wire tied; graded broken stone filling 230 mm deep 0.15 10.83 2.37 19.34 m2 32.55 Heavily galvanised woven wire mesh, wire tied; graded broken stone filling 300 mm deep 0.15 10.83 2.37 22.01 m2 35.22