ABSTRACT

ROAD LIGHTING COLUMNS AND BRACKETS, WALL MOUNTINGS, CCTV MASTS AND CANTILEVER MASTS Galvanised steel road lighting columns to BS EN 40 with flange plate base (including all control gear, switching, fuses and internal wiring) 4.0 m nominal height 0.75 37.46 18.95 188.26 nr 244.67 6.0 m nominal height 0.80 39.96 27.71 343.20 nr 410.86 8.0 m nominal height 0.96 47.95 33.25 429.87 nr 511.06 10.0 m nominal height 1.28 63.93 44.33 509.81 nr 618.08 12.0 m nominal height 1.44 71.93 49.87 718.08 nr 839.88 15.0 m nominal height 1.76 87.91 60.95 1056.33 nr 1205.20 3.0 m cast iron column (pedestrian / landscape area) 0.75 37.46 25.98 298.03 nr 361.48 Precast concrete lighting columns to BS EN 40 with flange plate base (including all control gear, switching, fuses and internal wiring) 5.0 m nominal height 0.75 37.46 25.98 238.50 nr 301.94 10.0 m nominal height 1.28 63.93 44.37 575.93 nr 684.23 Galvanised steel bracket arm to BS EN 40; with 5 degrees uplift 0.5 m projection, single arm 0.16 9.97 19.92 38.40 nr 68.29 1.0 m projection, single arm 0.19 11.84 12.84 82.08 nr 106.75 1.5 m projection, single arm 0.21 10.49 13.96 77.73 nr 102.18 2.0 m projection, single arm 0.27 16.82 18.24 108.90 nr 143.97 1.0 m projection, double arm 0.29 18.07 19.60 136.18 nr 173.84 2.0 m projection, double arm 0.32 19.94 21.62 164.22 nr 205.78 Precast concrete bracket arm to BS EN 40; with 5 degrees uplift 1.0 m projection, single arm 0.24 14.95 16.22 155.78 nr 186.95 2.0 m projection, single arm 0.32 19.94 21.62 186.91 nr 228.47 1.0 m projection, double arm 0.35 21.81 23.65 180.86 nr 226.32 2.0 m projection, double arm 0.37 23.05 25.00 219.79 nr 267.85 Lantern unit with photo-electric control set to switch on at 100 lux; lamps 55W SON (P226); to suit 4 m and 5 m columns 0.40 25.17 20.47 290.77 nr 336.41 70W SON (P236); to suit 5 m and 6 m columns 0.40 25.17 20.47 293.83 nr 339.47 250W SON (P426); to suit 8 m, 10 m and 12 m columns 0.50 31.46 25.59 440.74 nr 497.79 Sphere 70W SON; to suit 3 m columns (P456) 0.50 31.46 25.59 527.97 nr 585.02 400W SON High pressure sodium; to suit 12 m and 15 m columns 0.50 31.46 25.59 612.12 nr 669.17

Item

Gang hours

Labour £

Plant £

Material £ Unit

Total rate £

REMOVE FROM STORE AND RE-ERECT ROAD LIGHTING COLUMNS, AND BRACKETS, WALL MOUNTINGS, CCTV MASTS AND CANTILEVER MASTS

Re-erection of galvanised steel road lighting columns with flange plate base; including all control gear, switching, fuses and internal wiring

4.0 m nominal height 0.75 37.46 18.97 18.70 nr 75.13 6.0 m nominal height 0.80 39.96 20.25 24.46 nr 84.67 8.0 m nominal height 0.96 47.95 24.25 30.22 nr 102.42 10.0 m nominal height 1.28 63.93 32.37 35.97 nr 132.27 12.0 m nominal height 1.44 71.93 36.41 41.73 nr 150.07 15.0 m nominal height 1.76 87.91 44.50 50.36 nr 182.76 3.0 m cast iron column (pedestrian / landscape area) 0.75 37.46 18.99 15.82 nr 72.27

Re-erection of precast concrete lighting columns with flange plate base; including all control gear, switching, fuses and internal wiring

5.0 m nominal height 0.75 37.46 18.97 21.59 nr 78.02 10.0 m nominal height 1.28 63.93 32.37 35.97 nr 132.27

Re-erection of galvanised steel bracket arms 0.5 m projection, single arm 0.16 9.97 10.81 21.20 nr 41.98 1.0 m projection, single arm 0.19 11.84 12.84 21.20 nr 45.87 1.5 m projection, single arm 0.21 13.08 14.19 21.20 nr 48.47 2.0 m projection, single arm 0.27 16.82 18.24 21.20 nr 56.26 1.0 m projection, double arm 0.29 18.07 19.60 21.20 nr 58.86 2.0 m projection, double arm 0.32 19.94 21.62 21.20 nr 62.76

Re-erection of precast concrete bracket arms 1.0 m projection, single arm 0.24 14.95 16.22 21.20 nr 52.37 2.0 m projection, single arm 0.32 19.94 21.62 21.20 nr 62.76 1.0 m projection, double arm 0.35 21.81 24.41 21.20 nr 67.42 2.0 m projection, double arm 0.37 23.05 23.65 21.20 nr 67.90

Re-installing lantern unit with photo-electric control set to switch on at 100 lux; lamps

55W SON (P226); to suit 4 m and 5 m columns 0.40 25.17 20.47 - nr 45.64 70W SON (P236); to suit 5 m and 6 m columns 0.22 13.84 20.47 - nr 34.31 250W SON (P426); to suit 8 m, 10 m and 12 m columns 0.50 31.46 25.59 - nr 57.05 Sphere 70W SON; to suit 3 m (P456) 0.50 31.46 25.59 - nr 57.05 400W SON High pressure sodium; to suit 12 m and 15 m columns 0.50 31.46 25.59 - nr 57.05