ABSTRACT

Abstract The control of the setting accelerator dosage is normally dependent on the operator’s experience. This paper reports the results of an investigation of the influence of setting accelerator dosage on durability of wet mixed sprayed concrete used in tunnel linings. The experimental program includes tests on samples collected from tunnel linings in construction and from sample panels sprayed in the tunnel.