ABSTRACT

the same water pressure as the numerical computations. This causes disagreement between computed and measured values in short periods after the test starts. With time passing, however, computed and observed values approach to a stable state condition and show good similarities. It should be noticed that spatial distribution of water pressure shows similar shape to that of air pressure in three hours. As the result, suction takes a constant value whole the soil column(Pig.5).