ABSTRACT

Table 66.1 contains the currents in amperes (A) at which 100 randomly selected fuses from a manufacturing lot failed during surveillance testing [1]. The fuses had a 5 A rating. Failure Currents (A) for 100 Fuses

4.43

4.72

4.79

4.88

4.94

5.03

5.10

5.19

5.32

4.43

4.72

4.79

4.88

4.95

5.03

5.10

5.20

5.37

4.53

4.73

4.79

4.88

4.96

5.04

5.11

5.20

5.39

4.58

4.73

4.80

4.88

4.97

5.04

5.11

5.21

5.46

4.60

4.73

4.80

4.89

4.98

5.05

5.11

5.21

4.64

4.73

4.80

4.90

4.98

5.05

5.12

5.21

4.64

4.75

4.81

4.91

5.00

5.06

5.12

5.21

4.65

4.77

4.83

4.92

5.01

5.07

5.14

5.22

4.66

4.77

4.84

4.93

5.01

5.07

5.15

5.24

4.67

4.78

4.85

4.94

5.02

5.08

5.16

5.25

4.67

4.78

4.86

4.94

5.02

5.10

5.18

5.26

4.69

4.78

4.87

4.94

5.02

5.10

5.19