ABSTRACT

The prying force in a bolted circular flange joint can be up to 70% of the applied tension force and the determination of such a force is important for the design of the bolts and the flanges in the joint. In this paper the behaviour of prying action in circular flange joints is studied and the influences of joint dimensions on prying action are investigated. Charts are presented for the evaluation of prying forces in joints with different dimensions.