ABSTRACT

To simplify the non-linear dynamic design procedure on a moment-resisting steel frame to seismic actions, a new design-friendly reduced analysis method is proposed, and its validity is checked by comparison with a detailed computer analysis on a 6-story 2-bay frame model as well as a pseudo-dynamic test on a steel frame specimen.