ABSTRACT

This paper introduces and analyzes the production and processing process of the light-duty anti-corrosion partially prestressed RPC transmission towers in detail, and analyzes the mechanical performance tests in detail with the test data. The production of RPC (Reactive Powder Concrete) transmission towers is divided into raw material preparation, steel bar processing and skeleton forming, reactive powder concrete preparation, prestressing, centrifugal forming and other processes. Through the analysis of the mechanical properties, it is concluded that the force of the RPC transmission tower is divided into the elastic phase, the working phase with cracks, and the failure phase. The force performance of the transmission tower conforms to the theoretical calculation results, and the production and processing of the product is reasonable, which meets the conditions of promotion and application.