ABSTRACT

In order to ensure the structural safety and stability of a concrete frame structure self-built house, in this paper, the rangefinder and concrete rebound meter are used to carry out the quality detection and seismic identification of the concrete frame structure building. The relevant detection data are obtained. Based on the field test data, the structure is modeled and calculated by the structural analysis software. The results show that the static safety of the existing structure of the building basically meets the normal safe use requirements, and the comprehensive seismic capacity of the existing structure of the building basically meets the seismic evaluation requirements of the relevant codes.