Overvoltage analysis and suppression in the double-neutral section electrical sectioning device
DOI link for Overvoltage analysis and suppression in the double-neutral section electrical sectioning device
Overvoltage analysis and suppression in the double-neutral section electrical sectioning device book
Overvoltage analysis and suppression in the double-neutral section electrical sectioning device
DOI link for Overvoltage analysis and suppression in the double-neutral section electrical sectioning device
Overvoltage analysis and suppression in the double-neutral section electrical sectioning device book
Click here to navigate to parent product.
ABSTRACT
Overvoltage is easily caused when an electric locomotive goes through an electrical sectioning device, thereby leading to the breakdown of the equipment’s insulation. A bilateral passive RC suppression method is proposed to restrain overvoltage using an eight-span overlapping electrical sectioning device. The maximum overvoltage on the bilateral passive RC circuit of the eight-span electrical sectioning device over 60 kV and suppressive effect is obvious. Operating experience and experiments show that overvoltage is caused by electric locomotive going through seven-span electrical sectioning device in a short time. However, when electric locomotive goes through double-neural section electrical sectioning overlap, threefold overvoltage still may be produced, which is close to the value of overvoltage of locomotive roof insulation. Former researches pointed out that low-frequency oscillation voltage of neutral line has a great effect on overvoltage. Thus, in order to study overvoltage protection, bilateral suppression circuit is adopted in the double-neutral section.