ABSTRACT

This paper reports the results from fatigue testing on welded non-load-carrying transverse attachments made of C-Mn (S460) and stainless (LDX2101) steels. The tests are done on 40 mm thick specimens in as-welded and HFMI-treated specimens. Measurements on weld toe radius and weld residual stresses are also reported. The results show that the improvement of fatigue strength that can be achieved by HFMI-treatment on welded LDX2101 steel is similar to what is obtained for equivalent C-Mn steels. Also in the as-welded condition do these two types of steel show similar fatigue strength. HFMI-treatment gives more than 5 steps increase in fatigue strength for both steels, which is higher than what specified, for example by the recommendations of the International Institute of Welding.