ABSTRACT

ABSTRACT The capacity of existing bridges is an important aspect regarding the safety of the traveling public. Proof load testing can be a useful option to evaluate if an existing bridge satisfies the requirements from the code. The stop criteria provided by the Guidelines are generally suitable for flexure only. Therefore, in this paper, shear is considered. When developing a stop criterion for shear for proof load tests on existing bridges, many different approaches could be taken. Here, a stop criterion is developed based on the Critical Shear Displacement Theory. The development of the stop criterion is based on the analysis of the contribution of each of the mechanisms of shear transfer. The criterion is verified with experiments on beams in the laboratory. The consequence of this development is that now a stop criterion for shear with a theoretical basis is provided.