ABSTRACT

The application of organic-based corrosion inhibitors by migration under the presence of an electric field promotes similar polarizations of the rebar to the case in which the electric field was connected without inhibitor. The cathodic polarizations of the rebars are related in all cases with an important increase of i

values. Nevertheless, when the transport of the mixed

inhibitor CI is considered, the time in which a new situation of protection against corrosion is reached is reduced.