ABSTRACT

This is an effort to characterize the lowest possible order approximation to how HID lamps of different wattages should scale. We are after broad, simple relationships that a connect lamp's power to its dimensions. We consider ceramic lamps of constant low aspect ratio. The current discussion estimates relationships between the lamp's rated power P and the inner radius R . Corresponding wall-loading expressions are also derived.