ABSTRACT

16Dissolved organic matter (DOM) in source water highly influences the removal of different contaminants and dissolution of aquifer materials during bank filtration (BF). The fate of DOM during BF processes under hot arid climate conditions was analysed by conducting laboratory–scale batch and column studies under different environmental conditions with varying temperature (20–30°C), redox, and feed water organic matter composition. The behaviour of the DOM fractions was monitored using various analytical techniques: fluorescence excitation-emission matrix spectroscopy coupled with parallel factor analysis (PARAFAC-EEM), and size exclusion liquid chromatography with organic carbon detection (LC-OCD/OND). The results revealed that DOM attenuation is highly dependent (p<0.05) on redox conditions and temperature, with higher removal at lower temperatures and oxic conditions. Biopolymers were the fraction most amenable to removal by biodegradation (>80%) in oxic environments irrespective of temperature and feed water organic composition. The removal was 20–24% lower under sub-oxic conditions. In contrast, removal of humic compounds exhibited higher dependency on temperature. PARAFAC-EEM revealed that terrestrial humic components are the most temperature dependent fractions during the BF processes as their sorption characteristics are negatively correlated with temperature. In general, it can be concluded that BF is capable to remove labile compounds under oxic conditions at all water temperatures; however, its efficiency is lower for humic compounds at higher temperatures.