ABSTRACT

The results of tensile lap-shear tests of coatings produced on FRP substrates for different process schemes with and without plasma pretreatment are shown in Table 21.1. Examination of failed surfaces showed that separation occurred at the interface between the substrate and the bottom of the plasma film. No failure occurred between the plasma film and electrocopper layer.