ABSTRACT

Metal post and wire 1.20m high; DfT type 3; timber posts, driven; cleft chestnut paling 0.07 2.98 2.07 9.59 m 14.64 0.90m high; DfT type 4; galvanized rectangular wire mesh 0.13 5.53 3.85 9.59 m 18.97 1.275m high; DfT type 1; galvanized wire, 2 barbed, 4 plain 0.06 2.55 1.78 5.33 m 9.66 1.275m high; DfT type 2; galvanized wire, 2 barbed, 4 plain 0.06 2.55 1.78 8.00 m 12.33

Timber post and wire 1.20m high; DfT type 3; timber posts, driven; cleft chestnut paling 0.07 2.98 2.07 9.59 m 14.64 0.90m high; DfT type 4; galvanized rectangular wire mesh 0.13 5.53 3.85 9.59 m 18.97 1.275m high; DfT type 1; galvanized wire, 2 barbed, 4 plain 0.06 2.55 1.78 5.33 m 9.66 1.275m high; DfT type 2; galvanized wire, 2 barbed, 4 plain 0.06 2.55 1.78 8.00 m 12.33

Timber closeboarded; concrete posts Timber closeboarded

1.80m high; 125×125mm posts 0.30 12.75 8.88 42.64 m 64.27

Wire rope safety fencing to BS 5750; based on 600m lengths Metal crash barriers

600mm high; 4 wire ropes; long line posts at 2.40m general spacings, driven 0.16 11.18 4.74 59.14 m 75.06 600mm high; 4 wire ropes; short line posts at 2.40m general spacings, 400×400× 600mm concrete footing 0.27 18.86 7.99 61.28 m 88.13 600mm high; 4 wire ropes; short line posts at 2.40m general spacings, 400×400× 600mm concrete footing, socketed 0.32 22.35 9.47 61.47 m 93.29 600mm high; 4 wire ropes; short line posts at 2.40m general spacings, bolted to structure 0.20 13.97 5.92 58.43 m 78.32

hours £ £ £ rate £

Pedestrian guard rails Metal guard rails

1000mm high; tubular galvanized mild steel to BS 3049, mesh infill (105 swg, 50×50mm mesh); steel posts with concrete footing 0.80 11.02 4.74 73.19 m 88.95

Beam safety fencing; based on 600m lengths Metal crash barriers

600mm high; untensioned corrugated beam, single sided; long posts at 3.20m general spacings, driven 0.10 6.99 2.96 71.00 m 80.95 600mm high; untensioned corrugated beam, double sided; long posts at 3.20m general spacings, driven 0.26 18.16 7.69 130.69 m 156.54 600mm high; untensioned open box beam, single sided; long posts at 3.20m general spacings, driven 0.10 6.99 2.96 66.36 m 76.31 600mm high; untensioned open box beam, double sided; long posts at 3.20m general spacings, driven 0.26 18.16 7.69 121.72 m 147.57 600mm high; untensioned open box beam, double height; long posts at 3.20m general spacings, driven 0.30 20.95 8.88 142.38 m 172.21 600mm high; tensioned corrugated beam, single sided; long posts at 3.20m general spacings, driven 0.13 9.08 3.85 62.47 m 75.40 600mm high; tensioned corrugated beam, double sided; long posts at 3.20m general spacings, driven 0.37 25.84 10.95 113.63 m 150.42

GATES AND STILES

Notes Refer to Part 7 Series 300. Timber field gates

single; 3.00m wide×1.27m high 1.84 78.23 53.82 261.17 nr 393.22 single; 3.60m wide×1.27m high 1.90 80.78 55.58 277.16 nr 413.52 single; 4.10m wide×1.27m high 2.00 85.03 58.50 293.15 nr 436.68 single; 4.71m wide×1.27m high 2.00 85.03 58.50 319.80 nr 463.33

Timber wicket gates single;1.20m wide×1.20m high; DfT Type 1 1.20 51.02 35.10 133.25 nr 219.37 single; 1.20m wide×1.02m high; DfT Type 2 1.20 51.02 35.10 186.55 nr 272.67

Metal field gates single; steel tubular; 3.60m wide×1.175m high 0.30 12.75 8.78 146.37 nr 167.90 single; steel tubular; 4.50m wide×1.175m high 0.30 12.75 8.78 167.28 nr 188.81 single; steel tubular; half mesh; 3.60m wide× 1.175m high 0.30 12.75 8.78 172.51 nr 194.04 single; steel tubular; half mesh; 4.50m wide× 1.175m high 0.30 12.75 8.78 193.42 nr 214.95 single; steel tubular; extra wide; 4.88m wide× 1.175m high 0.30 12.75 8.78 198.65 nr 220.18 double; steel tubular; 5.02m wide×1.175m high 0.60 25.51 17.55 214.33 nr 257.39

hours £ £ £ rate £

GATES AND STILES – cont

Notes – cont Stiles

1.00m wide×1.45m high; DfT Type 1 1.50 63.77 43.88 111.93 nr 219.58 1.00m wide×1.45m high; DfT Type 2 1.40 59.52 40.95 79.95 nr 180.42

DRAINAGE TO STRUCTURES ABOVE GROUND

Note Outputs are based on heights up to 3m above ground and exclude time spent on erecting access equipment, but include marking, cutting, drilling to wood, brick or concrete and all fixings. testing of finished work is not included. Output multipliers for labour and plant for heights over 3m:

3-6m×1.25 6-9m×1.50 9-12m×1.75 12-15m×2.00

Cast iron gutters and fittings; BS 460 2002 100×75mm gutters; support brackets 0.25 6.94 0.29 57.40 m 64.63

stop end 0.03 0.75 0.03 44.99 nr 45.77 running outlet 0.04 0.97 0.04 71.62 nr 72.63 angle 0.04 0.97 0.04 46.05 nr 47.06

125×75mm gutters; support brackets 0.30 8.33 0.34 71.13 m 79.80 stop end 0.03 0.89 0.04 52.59 nr 53.52 running outlet 0.04 1.11 0.05 87.96 nr 89.12 angle 0.04 1.11 0.05 86.92 nr 88.08

Cast iron rainwater pipes and fittings; BS 460 2002 65mm dia.; support brackets 0.26 7.22 0.30 39.95 m 47.47

bend 0.28 7.77 0.32 20.78 nr 28.87 offset, 75mm projection 0.30 8.33 0.34 31.79 nr 40.46 offset, 225mm projection 0.30 8.33 0.34 37.02 nr 45.69 offset, 455mm projection 0.30 8.33 0.34 101.29 nr 109.96 shoe 0.18 5.00 0.21 33.95 nr 39.16

75mm dia.; support brackets 0.28 7.77 0.32 57.07 m 65.16 bend 0.28 7.77 0.32 33.42 nr 41.51 offset, 75mm projection 0.30 8.33 0.34 31.79 nr 40.46 offset, 225mm projection 0.30 8.33 0.34 37.02 nr 45.69 offset, 455mm projection 0.30 8.33 0.34 101.29 nr 109.96 shoe 0.18 5.00 0.21 33.95 nr 39.16

PVC-u gutters and fittings; Marley 116× 75mm gutters; support brackets 0.18 5.00 0.21 13.75 m 18.96

stop end 0.05 1.39 0.06 4.51 nr 5.96 running outlet 0.05 1.39 0.06 16.12 nr 17.57 angle 0.14 3.89 0.16 19.67 nr 23.72

hours £ £ £ rate £

150mm half round gutters; support brackets 0.18 5.00 0.21 16.21 m 21.42 stop end 0.05 1.39 0.06 7.16 nr 8.61 running outlet 0.05 1.39 0.06 19.84 nr 21.29 angle 0.14 3.89 0.16 18.12 nr 22.17

PVC-u external rainwater pipes and fittings; Marley 68mm dia.; support brackets 0.15 4.16 0.17 8.28 m 12.61

bend 0.16 4.44 0.18 8.66 nr 13.28 offset bend 0.18 5.00 0.21 5.04 nr 10.25 shoe 0.10 2.78 0.12 7.88 nr 10.78

110mm dia.; support brackets 0.15 4.16 0.17 18.86 m 23.19 bend 0.16 4.44 0.18 22.36 nr 26.98 offset bend 0.18 5.00 0.21 21.63 nr 26.84 shoe 0.10 2.78 0.12 18.08 nr 20.98

ROCK FILLED GABIONS

Gabions PVC coated galvanized wire mesh box gabions, wire laced; graded broken stone filling

1.0 × 1.0m module sizes 0.65 48.86 15.47 65.22 m3 129.55 1.0 × 0.5m module sizes 0.80 60.14 19.04 79.95 m3 159.13

Heavily galvanized woven wire mesh box gabions, wire laced; graded broken stone filling

1.0 × 1.0m module sizes 0.65 48.86 15.47 59.20 m3 123.53 1.0 × 0.5m module sizes 0.80 60.14 19.04 71.70 m3 150.88

Reno mattresses PVC coated woven wire mesh mattresses, wire tied; graded broken stone filling

230mm deep 0.15 11.28 3.57 21.03 m2 35.88 Heavily galvanized woven wire mesh, wire tied; graded broken stone filling

300mm deep 0.15 11.28 3.57 24.43 m2 39.28