ABSTRACT
GENERAL CLEARANCE
The rates for site clearance include for all sundry items, small trees (i.e. under 500 mm diameter), hedges etc., but exclude items that are measured separately; examples of which are given in this section
Clear site vegetation
generally – – – – ha 810.00 wooded areas – – – – ha 2500.00 areas below tidal level
– – – – ha 3000.00
TREES The following rates are based on removing a minimum of 100 trees, generally in a group. Cutting down a single tree on a site would be many times these costs Remove trees
girth 500 mm1 m
– – – – nr 30.00
girth 3-5 m – – – – nr 750.00 girth 7 m – – – – nr 900.00 STUMPS Clearance of stumps
diameter 150500 mm
– – – – nr 22.42
diameter 500 mm-1 m
– – – – nr 41.29
diameter 2 m – – – – nr 90.84 Clearance of stumps; backfilling holes with topsoil from site
diameter 150500 mm
– – – – nr 25.96
diameter 500 mm-1 m
– – – – nr 66.07
diameter 2 m – – – – nr 208.80 Clearance of stumps; backfilling holes with imported hardcore
diameter 150500 mm
– – – – nr 42.47
diameter 500 mm-1 m
– – – – nr 159.25
diameter 2 m – – – – nr 562.71 BUILDINGS The following rates are based on assuming a non urban location where structure does not take up a significant area of the site
Demolish building to ground level and dispose off
timber floor and roof
brickwork with concrete floor and roof
– – – – m37.62
masonry with timber floor and roof
– – – – m35.96
reinforced concrete frame with brick infill
– – – – m37.93
steel frame with brick cladding
– – – – m34.31
rate £ steel frame with sheet cladding
– – – – m34.10
timber – – – – m33.64 Demolish buildings with asbestos linings to
ground level and dispose off site
brick with concrete floor and roof
– – – – m316.87
reinforced concrete frame with brick infill
– – – – m317.55
steel frame with brick cladding
– – – – m39.60
steel frame with sheet cladding
– – – – m39.26
OTHER STRUCTURES
The following rates are based on assuming a non urban location where
significant area of the site Demolish walls to ground level and dispose off site
reinforced concrete wall
– – – – m3100.00
brick or masonry wall
– – – – m345.00
brick or masonry retaining wall
– – – – m355.00
PIPELINES Removal of redundant services electric cable; LV
– – – – m 1.86
75 mm diameter water main; low pressure
– – – – m 2.48
150 mm diameter gas main; low pressure
– – – – m 3.59
earthenware ducts; one way
– – – – m 2.48
earthenware ducts; two way
– – – – m 3.10
100 or 150 mm diameter sewer or drain
– – – – m 3.72
225 mm diameter sewer or drain
– – – – m 4.35
300 mm diameter sewer or drain
– – – – m 7.20
450 mm diameter sewer or drain
– – – – m 11.16
750 mm diameter sewer or drain
– – – – m 20.44
Extra for breaking up
– – – – m 4.95
Grouting redundant drains or sewers
100 mm diameter
– – – – m 4.35
150 mm diameter
– – – – m 6.52
225 mm diameter
– – – – m 11.47
manhole chambers
– – – – m392.97