Three bedroom, five person house; Type A

Ground floor Living room

1 no. pendant light fitting 3 no. double socket outlets; switched 1 no. plate switche

Kitchen 1 no. fluorescent fitting 1 no. plate switch 4 no. double socket outlets; switched 1 no. cooker control unit with connection unit 1no. fuse connection unit for boiler 1 no. isolating switch for hob with connection unit 1 no. immersion switch with neon indicator 4 no. switched spurs 4 no. single socket outlets; switched 3 no. final connections to kitchen cupboard lights

Dining room 1 no. plate switch 1 no. single socket outlet; switched 3 no. double socket outlet; switched 1 no. pendant light fitting

Hall/external porch 2 no. batten light fittings 1 no. plate switch (hall, landing and outside light) 1 no. doublle socket outlet; switched 1 no. smoke alarm (interconnected) 1 no. bulkhead fitting; external

Store cupboard 1 no. batten light fitting 1 no. plate switch

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. single socket outlet; switched

Bedroom 1 (including en-suite) 3 no. double socket outlets, switched 1 no. pendant light fitting 1 no. plate switch

2 no. down light fittings (zones 1-3)

Bedroom 2 3 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 3 2 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 no. plate switch (external to bathroom) 3 no. down light fittings (zones 1-3)

Cylinder cupboard 1 no. double pole switched connection unit with flex outlet for immersion heater

Four bedroom, six person house; Type B

Ground floor Living room

1 no. pendant light fitting 4 no. double socket outlets; switched 1 no. plate switch

1 no. fluorescent fitting 1 no. plate switch 4 no. double socket outlets; switched 1 no. fuse connection for boiler 1 no. cooker control unit with connection unit 1 no. isolating switch for hob with connection unit 1 no. immersion switch with neon indicator 4 no. switched spurs 4 no. single socket outlets; switched 4 no. final connections to kitchen cupboard lights

Dining room 1 no. plate switch 1 no. single socket outlet; switched 3 no. double socket outlets; switched 1 no. pendant light fitting

Hall/external porch 1 no. batten light fitting 1 no. plate switch (hall, landing and outside light) 1 no. single socket outlet; switched 1 no. smoke alarm (interconnected) 1 no. bulkhead fitting; external

Store cupboard 1 no. batten light fitting 1 no. plate switch

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

Study area 1 no. pendant light fitting 1 no. plate switch 3 no. double socket outlets; switched

Garage 2 no. plate switches 3 no. double socket outlets; switched

Landing

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. double socket outlet; switched

Bedroom 1 (including en-suite) 4 no. double socket outlets; switched 2 no. pendant light fittings 1 no. plate switch 2 no. down light fittings (zones 1-3)

Bedroom 2 3 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 3 1 no. single socket outlet; switched 3 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 4 3 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 no. plate switch (external to bathroom) 3 no. down light fittings (zones 1-3)

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

Cylinder cupboard 1 no. double pole switched connection unit with flex outlet for immersion heater

Ground floor Living room

2 no. pendant light fittings 4 no. double socket outlets; switched 2 no. plate switches

Kitchen 1 no. fluorescent fitting 1 no. plate switch 5 no. double socket outlets; switched 1 no. cooker control unit with connection unit 1 no. isolating switch for hob with connection unit 1 no. immersion switch with neon indicator 3 no. switched spurs 3 no. single socket outlets; switched 4 no. final connections to kitchen cupboard lights

Utility room 1 no. fluorescent fitting 1 no. plate switch 3 no. double socket outlets; switched 3 no. switched spurs 3 no. single socket outlets; switched 1 no. switched spur to boiler

Dining room 2 no. plate switches 4 no. double socket outlet; switched 1 no. pendant light fitting

Porch/hall 1 no. pendant light fitting 1 no. batten light fitting 1 no. plate switch (porch/hall, landing and outside light) 2 no. double socket outlets; switched 1 no. smoke alarm (interconnected) 1 no. bulkhead fitting; external

1 no. plate switch

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

Study area 2 no. pendant light fittings 1 no. plate switch 5 no. double socket outlets; switched

Double garage 2 no. plate switches 5 no. double socket outlets; switched 4 no. batten lamp holders

First floor Landing

1 no. pendant light fitting 1 no. plate switch 1 no. smoke alarm (interconnected) 1 no. double socket outlet; switched

Bedroom 1 (including en-suite) 1 no. single socket outlets; switched 3 no. double socket outlets; switched 2 no. pendant light fittings 2 no. plate switches 3 no. down light fittings (zones 1-3)

Bedroom 2 3 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bedroom 3 3 no. double socket outlets; switched 2 no. pendant light fittings 1 no. plate switch

1 no. pendant light fitting 1 no. plate switch

Bedroom 5 3 no. double socket outlets; switched 1 no. pendant light fitting 1 no. plate switch

Bathroom 1 1 no. plate switch (external to bathroom) 3 no. down light fittings (zones 1-3)

Bathroom 2 1 no. plate switch (external to bathroom) 2 no. down light fittings (zones 1-3)

WC 1 no. batten lamp holder 1 no. plate switch (external to WC)

Cylinder cupboard 1 no. double pole switched connection unit with flex outlet for immersion heater

The external bulkhead fittings are manufactured by Thorn' and are fixed to the soffit of the porch. On completion of the work an NICEIC is produced and the Contractor demonstrates to the owner the operation of the RCCB and MCBs and leaves a written instruction covering this operation for future use.