ABSTRACT
Thickness 215mm vertical straight walls 0.44 50.21 3.29 57.66 m2 111.16 vertical curved walls 0.57 64.74 4.25 57.66 m2 126.65 battered straight walls 0.63 68.89 4.70 57.66 m2 131.25 battered curved walls 0.71 77.64 5.25 57.66 m2 140.55 vertical facing to concrete 0.48 52.49 3.56 58.21 m2 114.26 battered facing to concrete 0.71 77.64 5.25 58.21 m2 141.10 casing to metal sections 0.61 66.70 4.51 58.21 m2 129.42
hours £ £ £ rate £
Thickness 328mm vertical straight walls 0.64 69.98 4.80 87.14 m2 161.92 vertical curved walls 0.82 89.67 6.13 87.14 m2 182.94 battered straight walls 0.91 99.51 6.76 87.14 m2 193.41 battered curved walls 1.01 110.44 7.53 87.14 m2 205.11 vertical facing to concrete 0.69 75.45 5.17 87.69 m2 168.31 battered facing to concrete 1.01 110.44 7.53 87.69 m2 205.66 casing to metal sections 0.87 95.13 6.49 87.69 m2 189.31
Thickness 440mm vertical straight walls 0.84 91.85 6.22 116.47 m2 214.54 vertical curved walls 1.06 115.91 7.88 116.47 m2 240.26 battered straight walls 1.16 126.85 8.66 116.47 m2 251.98 battered curved walls 1.29 141.06 9.60 116.47 m2 267.13 vertical facing to concrete 0.90 98.42 6.69 117.01 m2 222.12 battered facing to concrete 1.29 141.06 9.60 117.02 m2 267.68 casing to metal sections 1.12 122.47 8.33 117.02 m2 247.82
Thickness 890mm vertical straight walls 1.50 164.03 11.18 233.96 m2 409.17 vertical curved walls 1.85 202.30 13.80 233.96 m2 450.06 battered straight walls 2.00 218.70 14.97 233.96 m2 467.63 battered curved walls 2.20 240.57 16.36 233.96 m2 490.89 vertical facing to concrete 1.60 174.96 11.94 234.50 m2 421.40 battered facing to concrete 2.20 240.57 16.36 234.50 m2 491.43 casing to metal sections 1.94 212.14 14.48 234.50 m2 461.12
Thickness exceeding 1m vertical straight walls 1.64 179.33 12.19 261.87 m2 453.39 vertical curved walls 2.00 218.70 14.96 261.87 m2 495.53 battered straight walls 2.17 237.29 16.19 261.87 m2 515.35 battered curved walls 2.37 259.16 17.63 261.87 m2 538.66 vertical facing to concrete 1.74 190.27 12.99 262.42 m2 465.68 battered facing to concrete 2.37 259.16 17.63 262.42 m2 539.21 casing to metal sections 2.10 229.63 15.67 262.42 m2 507.72
Columns and piers 215×215mm 0.13 14.22 0.97 12.75 m 27.94 440×215mm 0.24 26.24 1.79 25.73 m 53.76 665×328mm 0.44 48.11 3.28 58.17 m 109.56 890×890mm 1.10 120.28 8.20 208.15 m 336.63
Surface features copings; standard header-on-edge; 215mm wide × 103mm high 0.10 10.94 0.78 6.41 m 18.13 sills; standard header-on-edge; 215mm wide × 103mm high 0.13 14.22 0.93 6.26 m 21.41 rebates 0.30 32.80 2.24 – m 35.04 chases 0.35 38.27 2.61 – m 40.88 band courses; flush; 215mm wide 0.05 5.47 0.34 – m 5.81 band courses; projection 103mm; 215mm wide 0.05 5.47 0.37 – m 5.84 corbels; maximum projection 103mm; 215mmwide 0.15 16.40 1.12 6.18 m 23.70 pilasters; 328mm wide × 103mm projection – – 0.52 12.75 m 13.27 pilasters; 440mm wide × 215mm projection 0.12 13.12 0.89 28.74 m 42.75 plinths; projection 103mm×900mm wide 0.19 20.78 1.42 26.10 m 48.30 fair facing 0.06 6.56 0.42 – m2 6.98
hours £ £ £ rate £
COMMON BRICKWORK – cont
Common bricks in cement mortar designation (ii) – cont Ancillaries
bonds to existing work; to brickwork 1.50 164.03 11.18 29.48 m2 204.69 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork 103mm thick 0.06 6.56 0.45 0.97 nr 7.98 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork 215mm thick 0.12 13.12 0.86 1.42 nr 15.40 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork 103mm thick 0.15 16.40 1.12 1.42 nr 18.94 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork 215mm thick 0.29 31.71 2.16 2.10 nr 35.97 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; brickwork 103mm thick 0.18 19.68 1.30 1.65 nr 22.63 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; brickwork 215mm thick 0.34 37.18 2.53 2.40 nr 42.11
FACING BRICKWORK
Facing bricks; in plasticised cement mortar designation (iii) Thickness 103mm
vertical straight walls 0.34 37.18 2.53 43.84 m2 83.55 vertical curved walls 0.45 49.21 3.35 43.84 m2 96.40 battered straight walls 0.45 49.21 3.35 43.84 m2 96.40 battered curved walls 0.56 61.24 4.19 43.84 m2 109.27 vertical facing to concrete 0.37 40.46 2.66 44.39 m2 87.51 battered facing to concrete 0.56 61.24 4.19 44.39 m2 109.82 casing to metal sections 0.49 53.58 3.65 44.39 m2 101.62
Thickness 215mm vertical straight walls 0.57 62.33 5.18 88.21 m2 155.72 vertical curved walls 0.84 91.85 6.26 88.21 m2 186.32 battered straight walls 0.84 91.85 6.26 88.21 m2 186.32 battered curved walls 1.02 111.54 7.62 88.21 m2 207.37 vertical facing to concrete 0.66 72.17 4.92 88.75 m2 165.84 battered facing to concrete 1.02 111.54 7.62 88.75 m2 207.91 casing to metal sections 0.82 89.67 6.11 88.75 m2 184.53
Thickness 328mm vertical straight walls 0.83 90.76 6.16 132.97 m2 229.89 vertical curved walls 1.12 122.47 8.31 132.97 m2 263.75 battered straight walls 1.12 122.47 8.31 132.97 m2 263.75 battered curved walls 1.36 148.72 10.13 132.97 m2 291.82 vertical facing to concrete 0.88 96.23 6.53 133.51 m2 236.27 battered facing to concrete 1.36 148.72 10.13 133.51 m2 292.36 casing to metal sections 1.18 129.03 8.79 133.51 m2 271.33
hours £ £ £ rate £
Thickness 440mm vertical straight walls 1.08 118.10 8.05 177.57 m2 303.72 vertical curved walls 1.39 152.00 10.36 177.57 m2 339.93 battered straight walls 1.39 152.00 10.36 177.57 m2 339.93 vertical facing to concrete 1.09 119.19 8.14 178.11 m2 305.44 battered facing to concrete 1.39 152.00 10.36 178.11 m2 340.47 casing to metal sections 1.39 152.00 10.36 178.11 m2 340.47
Columns and piers 215×215mm 0.17 18.59 1.24 19.64 m 39.47 440×215mm 0.29 31.71 2.16 39.47 m 73.34 665×328mm 0.58 63.42 4.30 89.10 m 156.82
Surface features copings; standard header-on-edge; standard bricks; 215mm wide × 103mm high 0.13 14.22 1.00 9.20 m 24.42 flat arches; standard stretcher-on-end; 215mm wide × 103mm high 0.21 22.96 1.56 8.97 m 33.49 flat arches; standard stretcher-on-end; bullnosed special bricks; 103mm×215mm high 0.22 24.06 1.64 53.19 m 78.89 segmental arches; single ring;standard bricks; 103mm wide × 215mm high 0.37 40.46 2.76 8.97 m 52.19 segmental arches; two ring;standard bricks; 103mm wide × 440mm high 0.49 53.58 3.65 18.10 m 75.33 segmental arches; cut voussoirs; 103mm wide × 215mm high 0.39 42.65 2.91 21.87 m 67.43 rebates 0.33 36.09 2.46 – m 38.55 chases 0.37 40.46 2.76 – m 43.22 cornices; maximum projection 103mm; 215mm wide 0.37 40.46 2.76 8.90 m 52.12 band courses; projection 113mm; 215mm wide 0.06 6.56 0.41 – m 6.97 corbels; maximum projection 113mm; 215mmwide 0.37 40.46 2.76 8.90 m 52.12 pilasters; 328mm wide × 113mm projection 0.05 5.47 0.37 19.63 m 25.47 pilasters; 440mm wide × 215mm projection 0.06 6.56 0.41 44.20 m 51.17 plinths; projection 113mm×900mm wide 0.24 26.24 1.79 39.85 m 67.88 fair facing; pointing as work proceeds 0.06 6.56 0.45 – m2 7.01
Ancillaries bonds to existing work; to brickwork 1.50 164.03 11.18 12.09 m 187.30 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork half brick thick 0.10 10.94 0.71 0.95 nr 12.60 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork one brick thick 0.15 16.40 0.74 1.67 nr 18.81 built-in pipes and ducts, cross-sectional area 0.050.25m2; excluding supply; brickwork half brick thick 0.19 20.78 1.42 1.50 nr 23.70 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork one brick thick 0.33 36.09 2.46 2.43 nr 40.98 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; brickwork half brick thick 0.23 25.15 1.71 1.73 nr 28.59 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; brickwork one brick thick 0.40 43.74 2.94 2.81 nr 49.49
hours £ £ £ rate £
ENGINEERING BRICKWORK
Class A engineering bricks, solid; in cement mortar designation (ii) Thickness 103mm
vertical straight walls 0.27 29.52 2.01 58.43 m2 89.96 vertical curved walls 0.37 40.46 2.76 58.43 m2 101.65 battered straight walls 0.37 40.46 2.76 58.43 m2 101.65 battered curved walls 0.41 44.83 3.07 58.43 m2 106.33 vertical facing to concrete 0.32 34.99 2.35 58.98 m2 96.32 battered facing to concrete 0.46 50.30 3.45 58.98 m2 112.73 casing to metal sections 0.41 44.83 3.07 58.98 m2 106.88
Thickness 215mm vertical straight walls 0.52 56.86 3.88 117.39 m2 178.13 vertical curved walls 0.71 77.64 5.25 117.39 m2 200.28 battered straight walls 0.71 77.64 5.25 117.39 m2 200.28 battered curved walls 0.78 85.29 5.81 117.39 m2 208.49 vertical facing to concrete 0.61 66.70 4.51 117.94 m2 189.15 battered facing to concrete 0.87 95.13 6.49 117.94 m2 219.56 casing to metal sections 0.78 85.29 5.81 117.94 m2 209.04
Thickness 328mm vertical straight walls 0.75 82.01 5.61 176.75 m2 264.37 vertical curved walls 1.01 110.44 7.53 176.75 m2 294.72 battered straight walls 1.01 110.44 7.53 176.75 m2 294.72 battered curved walls 1.11 121.38 8.28 176.75 m2 306.41 vertical facing to concrete 0.87 95.13 6.49 177.29 m2 278.91 battered facing to concrete 1.24 135.59 9.20 177.29 m2 322.08 casing to metal sections 1.11 121.38 8.28 177.29 m2 306.95
Thickness 440mm vertical straight walls 0.97 106.07 7.24 235.94 m2 349.25 vertical curved walls 1.29 141.06 9.60 235.94 m2 386.60 battered straight walls 1.29 141.06 9.60 235.94 m2 386.60 battered curved walls 1.41 154.18 10.51 235.94 m2 400.63 vertical facing to concrete 1.12 122.47 8.33 236.48 m2 367.28 battered facing to concrete 1.56 170.59 11.62 236.48 m2 418.69 casing to metal sections 1.41 154.18 10.51 236.48 m2 401.17
Thickness 890mm vertical straight walls 1.72 188.08 12.80 472.70 m2 673.58 vertical curved walls 2.20 240.57 16.36 472.70 m2 729.63 battered straight walls 2.20 240.57 16.36 472.70 m2 729.63 battered curved walls 2.37 259.16 17.66 472.70 m2 749.52 vertical facing to concrete 1.94 212.14 14.48 473.24 m2 699.86 battered facing to concrete 2.58 282.12 19.20 473.24 m2 774.56 casing to metal sections 2.37 259.16 17.66 473.24 m2 750.06
Thickness exceeding 1m vertical straight walls 1.87 204.48 13.90 529.12 m3 747.50 vertical curved walls 2.37 259.16 17.63 529.12 m3 805.91 battered straight walls 2.37 259.16 17.63 529.12 m3 805.91 battered curved walls 2.55 278.84 18.99 529.12 m3 826.95 vertical facing to concrete 2.10 229.63 15.67 529.59 m3 774.89 battered facing to concrete 2.76 301.81 20.57 529.59 m3 851.97 casing to metal sections 2.55 278.84 18.99 529.59 m3 827.42
hours £ £ £ rate £
Columns and piers 215×215mm 0.16 17.50 1.19 26.19 m 44.88 440×215mm 0.28 30.62 2.07 52.60 m 85.29 665×328mm 0.56 61.24 4.14 118.65 m 184.03 890×890mm 1.78 194.64 13.25 423.19 m 631.08
Surface features copings; standard header-on-edge; 215mm wide × 103mm high 0.11 12.03 0.78 13.14 m 25.95 sills; standard header-on-edge; 215mm wide × 103mm high 0.13 14.22 0.93 12.98 m 28.13 rebates 0.33 36.09 2.46 – m 38.55 chases 0.37 40.46 2.76 – m 43.22 band courses; flush; 215mm wide 0.05 5.47 0.34 – m 5.81 band courses; projection 103mm; 215mm wide 0.05 5.47 0.37 – m 5.84 corbels; maximum projection 103mm; 215mm wide 0.15 16.40 1.12 12.90 m 30.42 pilasters; 328mm wide × 103mm projection 0.07 7.65 0.52 26.19 m 34.36 pilasters; 440mm wide × 215mm projection 0.12 13.12 0.89 58.98 m 72.99 plinths; projection 103mm×900mm wide 0.19 20.78 1.42 52.98 m 75.18 fair facing 0.06 6.56 0.45 – m2 7.01
Ancillaries bonds to existing brickwork; to brickwork 0.29 31.71 2.16 17.01 m² 50.88 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork half brick thick 0.10 10.94 0.71 1.61 nr 13.26 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork one brick thick 0.15 16.40 1.12 2.19 nr 19.71 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork half brick thick 0.19 20.78 1.42 2.12 nr 24.32 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork one brick thick 0.33 36.09 2.46 3.06 nr 41.61 built-in pipes and ducts, cross-sectional area 0. 025-0.5m2; excluding supply; brickwork half brick thick 0.23 25.15 1.71 2.37 nr 29.23 built-in pipes and ducts, cross-sectional area 0. 025-0.5m2; excluding supply; brickwork one brick thick 0.40 43.74 2.94 3.45 nr 50.13
hours £ £ £ rate £
ENGINEERING BRICKWORK – cont
Class B engineering bricks, perforated; in cement mortar designation (ii) Thickness 103mm
vertical straight walls 0.27 29.52 2.01 27.94 m2 59.47 vertical curved walls 0.37 40.46 2.76 27.94 m2 71.16 battered straight walls 0.37 40.46 2.76 27.94 m2 71.16 vertical facing to concrete 0.32 34.99 2.35 28.49 m2 65.83 casings to metal sections 0.41 44.83 3.07 28.49 m2 76.39
Thickness 215mm vertical straight walls 0.52 56.86 3.88 56.41 m2 117.15 vertical curved walls 0.71 77.64 5.25 56.41 m2 139.30 battered straight walls 0.71 77.64 5.25 56.41 m2 139.30 vertical facing to concrete 0.61 66.70 4.51 56.96 m2 128.17 casings to metal sections 0.78 85.29 5.81 56.96 m2 148.06
Thickness 328mm vertical straight walls 0.76 83.11 5.63 85.28 m2 174.02 vertical curved walls 1.01 110.44 7.53 85.28 m2 203.25 battered straight walls 1.01 110.44 7.53 85.28 m2 203.25 vertical facing to concrete 0.87 95.13 6.49 85.82 m2 187.44 casings to metal sections 1.11 121.38 8.28 85.82 m2 215.48
Thickness 440mm vertical straight walls 0.97 106.07 7.24 113.98 m2 227.29 vertical curved walls 1.29 141.06 9.60 113.98 m2 264.64 battered straight walls 1.29 141.06 9.60 113.98 m2 264.64 vertical facing to concrete 1.12 122.47 8.33 114.53 m2 245.33 casings to metal sections 1.41 154.18 10.51 114.53 m2 279.22
Thickness 890mm vertical straight walls 1.72 188.08 12.80 228.79 m2 429.67 vertical curved walls 2.20 240.57 16.36 228.79 m2 485.72 battered straight walls 2.20 240.57 16.36 228.79 m2 485.72 battered curved walls 2.37 259.16 17.66 228.79 m2 505.61 vertical facing to concrete 1.94 212.14 14.48 229.34 m2 455.96 battered facing to concrete 2.58 282.12 19.20 229.34 m2 530.66 casing to metal sections 2.37 259.16 17.66 229.34 m2 506.16
Thickness exceeding 1m vertical straight walls 1.87 204.48 13.90 256.44 m3 474.82 vertical curved walls 2.37 259.16 17.63 256.44 m3 533.23 battered straight walls 2.37 259.16 17.63 256.44 m3 533.23 battered curved walls 2.55 278.84 18.99 256.44 m3 554.27 vertical facing to concrete 2.10 229.63 15.67 256.91 m3 502.21 battered facing to concrete 2.76 301.81 20.57 256.91 m3 579.29 casing to metal sections 2.55 278.84 18.99 256.91 m3 554.74
Columns and piers 215×215mm 0.16 17.50 1.19 12.47 m 31.16 440×215mm 0.28 30.62 2.07 25.17 m 57.86 665×328mm 0.56 61.24 4.14 56.91 m 122.29 890×890mm 1.78 194.64 13.25 203.67 m 411.56
hours £ £ £ rate £
Surface features copings; standard header-on-edge; 215mm wide × 103mm high 0.11 12.03 0.78 6.27 m 19.08 sills; standard header-on-edge; 215mm wide × 103mm high 0.13 14.22 0.93 6.12 m 21.27 rebates 0.33 36.09 2.46 – m 38.55 chases 0.37 40.46 2.76 – m 43.22 band courses; flush; 215mm wide 0.05 5.47 0.34 – m 5.81 band courses; projection 103mm; 215mm wide 0.05 5.47 0.37 – m 5.84 corbels; maximum projection 103mm; 215mm wide 0.15 16.40 1.12 6.04 m 23.56 pilasters; 328mm wide × 103mm projection 0.07 7.65 0.52 12.47 m 20.64 pilasters; 440mm wide × 215mm projection 0.12 13.12 0.89 28.11 m 42.12 plinths; projection 103mm×900mm wide 0.19 20.78 1.42 25.54 m 47.74 fair facing 0.06 6.56 0.45 – m2 7.01
Ancillaries bonds to existing brickwork; to brickwork 0.29 31.71 2.16 16.48 m² 50.35 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork half brick thick 0.10 10.94 0.71 1.61 nr 13.26 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; brickwork one brick thick 0.15 16.40 1.12 2.19 nr 19.71 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork half brick thick 0.19 20.78 1.42 2.12 nr 24.32 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; brickwork one brick thick 0.33 36.09 2.46 3.06 nr 41.61 built-in pipes and ducts, cross-sectional area 0. 025-0.5m2; excluding supply; brickwork half brick thick 0.23 25.15 1.71 2.37 nr 29.23 built-in pipes and ducts, cross-sectional area 0. 025-0.5m2; excluding supply; brickwork one brick thick 0.40 43.74 2.94 3.41 nr 50.09
hours £ £ £ rate £
LIGHTWEIGHT BLOCKWORK
Lightweight concrete blocks; 3.5N/mm2; in cement-lime mortar designation (iii) Thickness 100mm;
vertical straight walls 0.17 18.59 1.30 13.45 m2 33.34 vertical curved walls 0.23 25.15 1.72 13.45 m2 40.32 vertical facework to concrete 0.18 19.68 1.33 16.72 m2 37.73 casing to metal sections 0.21 22.96 1.56 16.72 m2 41.24
Thickness 140mm; vertical straight walls 0.23 25.15 1.68 18.74 m2 45.57 vertical curved walls 0.30 32.80 2.23 18.74 m2 53.77 vertical facework to concrete 0.23 25.15 1.73 22.04 m2 48.92 casing to metal sections 0.27 29.52 2.01 22.04 m2 53.57
Thickness 215mm; vertical straight walls 0.28 30.62 2.05 28.83 m2 61.50 vertical curved walls 0.37 40.46 2.73 28.83 m2 72.02 vertical facework to concrete 0.28 30.62 2.11 32.14 m2 64.87 casing to metal sections 0.31 33.90 2.31 32.14 m2 68.35
Columns and piers 440×100mm 0.08 8.75 0.60 5.93 m 15.28 890×140mm 0.22 24.06 1.64 16.83 m 42.53
Surface features fair facing 0.06 6.56 0.45 – m2 7.01
Ancillaries built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; blockwork 100mm thick 0.04 4.37 0.30 0.33 nr 5.00 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; blockwork 140mm thick 0.09 9.84 0.67 1.18 nr 11.69 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; blockwork 215mm thick 0.13 14.22 0.94 1.62 nr 16.78 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; blockwork 100mm thick 0.13 14.22 0.94 1.58 nr 16.74 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; blockwork 140mm thick 0.18 19.68 1.31 2.59 nr 23.58 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; blockwork 215mm thick 0.25 27.34 1.86 3.45 nr 32.65 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; blockwork 100mm thick 0.15 16.40 1.12 2.00 nr 19.52 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; blockwork 140mm thick 0.21 22.96 1.56 2.59 nr 27.11 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; blockwork 215mm thick 0.30 32.80 2.20 4.07 nr 39.07
hours £ £ £ rate £
DENSE CONCRETE BLOCKWORK
Dense concrete blocks; 7N/mm2; in cement mortar designation (iii) Walls, built vertical and straight
100mm thick 0.19 20.78 1.42 13.88 m2 36.08 140mm thick 0.25 27.34 1.85 17.18 m2 46.37 215mm thick 0.34 37.18 2.53 26.48 m2 66.19
Walls, built vertical and curved 100mm thick 0.25 27.34 1.89 13.91 m2 43.14 140mm thick 0.33 36.09 2.46 17.18 m2 55.73 215mm thick 0.45 49.21 3.37 26.51 m2 79.09
Walls, built vertical in facework to concrete 100mm thick 0.20 21.87 1.47 17.30 m2 40.64 140mm thick 0.26 28.43 1.90 20.23 m2 50.56 215mm thick 0.35 38.27 2.61 29.51 m2 70.39
Walls, as casings to metal sections, built vertical and straight
100mm thick 0.23 25.15 1.71 17.30 m2 44.16 140mm thick 0.30 32.80 2.20 20.23 m2 55.23
Columns and piers 440×100mm 0.08 8.75 0.59 4.95 m 14.29 890×140mm thick 0.22 24.06 1.64 15.45 m 41.15
Ancillaries built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; blockwork 100mm thick 0.05 5.47 0.34 0.33 nr 6.14 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; blockwork 140mm thick 0.10 10.94 0.75 1.09 nr 12.78 built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply; blockwork 215mm thick 0.14 15.31 1.01 1.53 nr 17.85 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; blockwork 100mm thick 0.14 15.31 1.01 1.67 nr 17.99 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; blockwork 140mm thick 0.19 20.78 1.42 2.40 nr 24.60 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply; blockwork 215mm thick 0.27 29.52 2.01 3.22 nr 34.75 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; blockwork 100mm thick 0.16 17.50 1.21 2.06 nr 20.77 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; blockwork 140mm thick 0.23 25.15 1.71 2.43 nr 29.29 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply; blockwork 215mm thick 0.32 34.99 2.38 3.80 nr 41.17
hours £ £ £ rate £
ARTIFICIAL STONE BLOCKWORK
Reconstituted stone masonry blocks; Bradstone 100 bed weathered Cotswold or North Cearney rough hewn rockfaced blocks; in coloured cement-lime mortar designation (iii) Thickness 100mm vertical facing
vertical straight walls 0.30 32.80 2.24 37.19 m2 72.23 vertical curved walls 0.39 42.65 2.91 37.19 m2 82.75 vertical facework to concrete 0.31 33.90 2.33 37.22 m2 73.45 casing to metal sections 0.40 43.74 2.98 37.22 m2 83.94
Ancillaries built-in pipes and ducts, cross-sectional area not exceeding 0.05m2; excluding supply 0.07 7.65 0.52 0.46 nr 8.63 built-in pipes and ducts, cross-sectional area 0.05-0.25m2; excluding supply 0.22 24.06 1.64 3.96 nr 29.66 built-in pipes and ducts, cross-sectional area 0. 25-0.5m2; excluding supply 0.26 28.43 1.94 4.97 nr 35.34
Reconstituted stone masonry blocks; Bradstone Architectural dressing in weathered Cotswald or North Cerney shades; in coloured cement-lime mortar designation (iii) Surface features; Pier Caps
305×305mm, weathered and throated 0.09 9.84 0.67 19.18 nr 29.69 381×381mm, weathered and throated 0.11 12.03 0.82 27.19 nr 40.04 457×457mm, weathered and throated 0.13 14.22 0.97 37.25 nr 52.44 533×533mm, weathered and throated 0.15 16.40 1.12 51.85 nr 69.37
Surface features; Copings 152×76mm, twice weathered and throated 0.08 8.75 0.60 8.48 m 17.83 152×76mm, curved on plan, twice weathered and throated 0.11 12.03 0.79 29.02 m 41.84 305×76mm, twice weathered and throated 0.10 10.94 2.98 14.48 m 28.40 305×76mm, curved on plan, twice weathered and throated 0.13 14.22 0.99 76.99 m 92.20
Surface features; Pilasters 440×100mm 0.14 15.31 1.04 16.38 m 32.73
Surface features; Corbels 479×100×215mm, splayed 0.49 53.58 3.65 128.82 nr 186.05 665×100×215mm, splayed 0.55 60.14 4.10 92.94 nr 157.18
Surface features; Lintels 100×140mm 0.11 12.03 0.82 39.93 m 52.78 100×215mm 0.16 17.50 1.19 52.02 m 70.71
hours £ £ £ rate £
ASHLAR MASONRY
PortlandWhitbed limestone; in cement-limemortar designation (iv); pointed one side cement-lime mortar designation (iii) incorporating stone dust Thickness 50mm
vertical facing to concrete 0.85 92.95 6.33 93.29 m2 192.57 Thickness 75mm
vertical straight walls 0.95 103.88 7.08 165.06 m2 276.02 vertical curved walls 1.45 158.56 10.81 292.72 m2 462.09
Surface features copings; weathered and twice throated; 250×150mm 0.45 49.21 3.35 123.20 m 175.76 copings; weathered and twice throated; 250×150mm; curved on plan 0.45 49.21 3.35 147.81 m 200.37 copings; weathered and twice throated; 400×150mm 0.49 53.58 3.65 181.09 m 238.32 copings; weathered and twice throated; 400×150mm; curved on plan 0.49 53.58 3.65 217.28 m 274.51 string courses; shaped and dressed; 75mm projection × 150mm high 0.45 49.21 3.35 100.33 m 152.89 corbel; shaped and dressed; 500×450 × 300mm 0.55 60.14 4.10 163.27 nr 227.51 keystone; shaped and dressed; 750×900 × 300mm (extreme) 1.30 142.16 9.69 516.50 nr 668.35
RUBBLE MASONRY
Rubble masonry; random stones; in cement-lime mortar designation (iii) Walls, built vertical and straight; not exceeding 2m high
300mm thick 1.25 136.69 9.31 246.48 m2 392.48 450mm thick 1.80 196.83 13.41 425.64 m2 635.88 600mm thick 2.40 262.44 17.88 492.93 m2 773.25
Walls, built vertical, curved on plan; not exceeding 2m high
300mm thick 1.40 153.09 5.27 252.23 m2 410.59 450mm thick 2.00 218.70 14.90 369.74 m2 603.34 600mm thick 2.65 289.78 19.75 492.93 m2 802.46
Walls, built with battered face; not exceeding 2m high 300mm thick 1.40 153.09 10.43 246.48 m2 410.00 450mm thick 2.00 218.70 14.90 369.74 m2 603.34 600mm thick 2.65 289.78 19.75 492.93 m2 802.46
Rubble masonry; squared stones; in cement-lime mortar designation (iii) Walls, built vertical and straight; not exceeding 2m high
300mm thick 1.25 136.69 9.31 444.92 m2 590.92 450mm thick 1.80 196.83 13.41 667.37 m2 877.61 600mm thick 2.40 262.44 17.88 889.85 m2 1170.17
hours £ £ £ rate £
RUBBLE MASONRY – cont
Rubble masonry – cont Walls, built vertical, curved on plan; not exceeding 2m high
300mm thick 1.40 153.09 10.43 444.92 m2 608.44 450mm thick 2.00 218.70 14.90 667.37 m2 900.97 600mm thick 2.40 262.44 17.88 936.85 m2 1217.17
Walls, built with battered face; not exceeding 2m high 300mm thick 1.40 153.09 10.43 444.92 m2 608.44 450mm thick 2.00 218.70 14.90 667.37 m2 900.97 600mm thick 2.40 262.44 17.88 936.85 m2 1217.17
Dry stone walling; random stones Average thickness 300mm
battered straight walls 1.15 125.75 3.73 227.24 m2 356.72 Average thickness 450mm
battered straight walls 1.65 180.43 5.36 340.82 m2 526.61 Average thickness 600mm
battered straight walls 2.15 235.10 6.98 454.45 m2 696.53 Surface features
copings; formed of rough stones 275×200mm (average) high 0.45 49.21 3.35 58.60 m 111.16 copings; formed of rough stones 500×200mm (average) high 0.55 60.14 4.10 106.55 m 170.79
ANCILLARIES COMMON TO ALL DIVISIONS
Expamet joint reinforcement Ancillaries
joint reinforcement; 65mm wide 0.01 1.09 0.05 0.60 m 1.74 joint reinforcement; 115mm wide 0.01 1.09 0.06 0.93 m 2.08 joint reinforcement; 175mm wide 0.01 1.09 0.08 1.13 m 2.30 joint reinforcement; 225mm wide 0.01 1.09 0.10 1.77 m 2.96
Hyload pitch polymer damp proof course; lapped joints; in cement mortar Ancillaries
103mm wide; horizontal 0.01 1.09 0.08 0.54 m 1.71 103mm wide; vertical 0.02 2.19 0.13 0.54 m 2.86 215mm wide; horizontal 0.03 3.28 0.19 1.94 m 5.41 215mm wide; vertical 0.04 4.37 0.30 1.94 m 6.61 328mm wide; horizontal 0.04 4.37 0.28 3.16 m 7.81 328mm wide; vertical 0.06 6.56 0.42 3.16 m 10.14
hours £ £ £ rate £
Pre-formed closed cell joint filler; pointing with polysulphide sealant Ancillaries
movement joints; 12mm filler 90 wide; 12×12 sealant one side 0.06 6.56 0.41 0.66 m 7.63 movement joints; 12mm filler 200 wide; 12×12 sealant one side 0.07 7.65 0.48 1.00 m 9.13
Dritherm cavity insulation Infills
50mm thick 0.04 4.37 0.30 2.60 m2 7.27 75mm thick 0.05 5.47 0.34 3.28 m2 9.09
Concrete Infills
50mm thick 0.06 6.56 0.42 4.99 m2 11.97
Galvanized steel wall ties Fixings and ties
vertical twist strip type; 900mm horizontal and 450mm vertical staggered spacings 0.02 2.19 0.11 0.13 m2 2.43
Stainless steel wall ties Fixings and ties
vertical twist strip type; 900mm horizontal and 450mm vertical staggered spacings 0.02 2.19 0.11 0.29 m2 2.59