ABSTRACT

The cracking moment capacity is calculated according to standard procedures and the concrete strength, the prestressed steel area and the bridge live load are considered as random variables.

Finally, the bridge is modeled as a single component, being the beam under corrosion the main element, the limit state is described by the event where the beam moment capacity is exceeded by the maximum acting moment.