ABSTRACT

Design a steam plant for a manufacturing facility to fulll the following requirements:

1. Provide steam for process equipment as described below: a. Process steam user 1: Steam usage of 11,000 lb/h (4,994 kg/h) at

approximately 140 psig (965 kPag) with 100% condensate return. Steam supply to the steam coil is controlled by an on-off valve with slow-moving actuator. The steam usage is continuous and steady during the production shifts.