ABSTRACT

Over the past decades, the piezocone testing has been increasingly adopted for field investigation as it offers a quick and cost-effective methodology for subsoil profiling and geotechnical parameters estimation. Although the piezocone testing has revealed good applicability worldwide, difficulties are encountered in complex soil conditions, such as soft sensitive clays. One of the key issues in such soils is represented by the poor quality of the sleeve friction (fs) measurement due to inaccuracy and poor resolution of the sleeve sensor. This paper investigates the influence of fs data quality on soil parameters determination with particular emphasis on the soil behavior type (SBT) chart classification. The field investigation was conducted in a soft sensitive clay site located in Finland using two different penetrometers: a standard piezocone and an advanced piezocone characterized by enhance accuracy sleeve friction sensor. Results show that the use of high-resolution piezocone plays a key role in soft clays to avoid misleading soil type classification.