ABSTRACT

A unified procedure on the same model and mesh for all simulations, excavation, dimensioning, reinforcement safety, ventilation, fire, in the tunnel design loop is presented. All nonlinear structural calculations are performed using a 3D model which includes elastoplastic behavior of the soil, temporary and permanent lining. The “hot” design carried out checks if sufficient load-bearing capacity is available in case of fire.